Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of agricultural and food chemistry 17 (1969), S. 356-360 
    ISSN: 1520-5118
    Source: ACS Legacy Archives
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Biochemistry 3 (1964), S. 1616-1623 
    ISSN: 1520-4995
    Source: ACS Legacy Archives
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of agricultural and food chemistry 24 (1976), S. 435-436 
    ISSN: 1520-5118
    Source: ACS Legacy Archives
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1238
    Keywords: Closed-loop controlled ventilation ; Human ; Initial settings ; Computer ; Mechanical ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. Design Prospective randomized crossover study. Setting ICUs in one adult and one children's hospital in Switzerland. Patients Thirty intubated stable, critically ill patients (20 adults and 10 children). Interventions The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilator (AutoInit). Measurements and results Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V DS), expiratory time constant (RC), tidal volume (V T), total respiratory frequency (f tot), minute ventilation (MV), and maximal and mean airway pressure (P aw, max andP aw, mean) were calculated. Arterial blood gases were analyzed at the end of each period.P aw, max was significantly less with the AutoInit ventilator settings whilef tot was significantly greater (P〈0.05). The other values were not statistically significant. Conclusions The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic startup procedure for mechanical ventilation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1238
    Keywords: Key words Closed-loop controlled ventilation ; Human ; Initial settings ; Computer ; Mechanical ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. Design: Prospective randomized crossover study. Setting: ICUs in one adult and one children’s hospital in Switzerland. Patients: Thirty intubated stable, critically ill patients (20 adults and 10 children). Interventions: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilator (AutoInit). Measurements and results: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V DS), expiratory time constant M28.6n(RC), tidal volume (V T), total respiratory frequency (f tot), minute ventilation (MV), and maximal and mean airway pressure (P aw,max and P aw,mean) were calculated. Arterial blood gases were analyzed at the end of each period. P aw,max was significantly less with the AutoInit ventilator settings while f tot was significantly greater (P〈0.05). The other values were not statistically significant. Conclusions: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1238
    Keywords: Key words Acute respiratory distress syndrome (ARDS) ; Respiration ; artificial ; Respiratory system ; mechanics ; time constants ; Lung compliance ; Airway resistance ; Lung volume measurement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: The aims of the present study were 1) to evaluate a method for identification of “slowly” distensible compartments of the respiratory system (rs), which are characterized by long mechanical time constants (RC) and 2) to identify “slowly” distensible rs-compartments in mechanically ventilated patients. Design: Prospective study on a physical lung model. Setting: Intensive Care Unit, University Hospital, Tübingen Patients and participants: 19 patients with severe lung injury (acute respiratory distress syndrome, ARDS) and on 10 patients with mild lung injury. Measurements and results: Positive end-expiratory pressure (PEEP)-increasing and -decreasing steps of about 5 cmH2O were applied and the breath-by-breath differences of inspiratory and expiratory volumes (ΔV) were measured. The sequence of ΔVs were analyzed in terms of volume change in the “fast” compartment (Vfast), the “slow” compartment (Vslow), total change in lung volume (ΔVL) and mechanical time constant of the slow compartment (RCslow). Thirty-eight measurements in a lung model revealed a good correlation between the preset Vslow/ΔVL and Vslow/ΔVL measured: r2=0.91. 28.6nThe Vslow/ΔVL measured amounted to 0.94±0.15 of Vslow/ΔVL in the lung model. RCslow measured was 0.92±0.43 of the RCslow reference. Starting from a PEEP level of 11 cmH2O PEEP-increasing and PEEP-decreasing steps were applied to the mechanically ventilated patients. Three out of ten patients with mild lung injury (30%) and 7/19 patients with ARDS (36.8%) revealed “slowly” distensible rs-compartments in a PEEP-increasing step, whereas 15/19 ARDS patients and 1/10 patients with mild lung injury showed “slowly” distensible rs-compartments in a PEEP-decreasing step (78.9% vs 10%, P〈0.002, chi-square test). Conclusions: The gas distribution properties of the respiratory system can be easily studied by a PEEP-step maneuver. The relative contribution of the “slow” units to the total increase of lung volume following a PEEP step could be adequately assessed. “Slowly” distensible rs-compartments could be detected in patients with severe and mild lung injury, however significantly more ARDS patients revealed “slow” rs-compartments in PEEP-decreasing steps. The influence of “slowly” distensible rs-compartments on pulmonary gas exchange is unknown and has yet to be studied.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-1238
    Keywords: Respiratory mechanics ; Respiratory resistance ; Respiratory compliance ; Mechanical ventilation ; Pressure support ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To evaluate a least squares fitting technique for the purpose of measuring total respiratory compliance (Crs) and resistance (Rrs) in patients submitted to partial ventilatory support, without the need for esophageal pressure measurement. Design Prospective, randomized study. Setting A general ICU of a University Hospital. Patients 11 patients in acute respiratory failure, intubated and assisted by pressure support ventilation (PSV). Interventions Patients were ventilated at 4 different levels of pressure support. At the end of the study, they were paralyzed for diagnostic reasons and submitted to volume controlled ventilation (CMV). Measurements and results A least squares fitting (LSF) method was applied to measure Crs and Rrs at different levels of pressure support as well as in CMV. Crs and Rrs calculated by the LSF method were compared to reference values which were obtained in PSV by measurement of esophageal pressure, and in CMV by the application of the constant flow, end-inspiratory occlusion method. Inspiratory activity was measured by P0.1. In CMV, Crs and Rrs measured by the LSF method are close to quasistatic compliance (−1.5±1.5 ml/cmH2O) and to the mean value of minimum and maximum end-inspiratory resistance (+0.9±2.5 cmH2O/(l/s)). Applied during PSV, the LSF method leads to gross underestimation of Rrs (−10.4±2.3 cmH2O/(l/s)) and overestimation of Crs (+35.2±33 ml/cmH2O) whenever the set pressure support level is low and the activity of the respiratory muscles is high (P0.1 was 4.6±3.1 cmH2O). However, satisfactory estimations of Crs and Rrs by the LSF method were obtained at increased pressure support levels, resulting in a mean error of −0.4±6 ml/cmH2O and −2.8±1.5 cmH2O/(l/s), respectively. This condition was coincident with a P0.1 of 1.6±0.7 cmH2O. Conclusion The LSF method allows non-invasive evaluation of respiratory mechanics during PSV, provided that a near-relaxation condition is obtained by means of an adequately increased pressure support level. The measurement of P0.1 may be helpful for titrating the pressure support in order to obtain the condition of near-relaxation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-1238
    Keywords: Acute respiratory distress syndrome (ARDS) ; Respiration, artificial ; Respiratory system, mechanis, time constants ; Lung compliance ; Airway resistance ; Lung volume measurement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective The aims of the present study were 1) to evaluate a method for identification of “slowly” distensible compartments of the respiratory system (rs), which are characterized by long mechanical time constants (RC) and 2) to identify “slowly” distensible rs-compartments in mechanically ventilated patients. Design Prospective studyon a physical lung model. Setting Intensive Care Unit, University Hospital, Tübingen. Patients and participants 19 patients with severe lung injury (acute respiratory distress syndrome, ARDS) and on 10 patients with mild lung injury. Measurements and results Positive end-expiratory pressure (PEEP)-increasing and-decreasing steps of about 5 cmH2O were applied and the breath-by-breath differences of inspiratory and expiratory volumes (ΔV) were measured. The sequence of ΔVs were analyzed in terms of volume change in the “fast” compartment (Vfast), the “slow” compartment (Vslow), total change in lung volume (ΔVL) and mechanical time constant of the slow compartment (RCslow). Thirty-eight measurements in a lung model revealed a good correlation between the preset Vslow/ΔVL and Vslow/ΔVL measured: r2=0.91 The Vslow/ΔVL measured amounted to 0.94±0.15 of Vslow/ΔVL in the lung model. RCslow measured was 0.92±0.43 of the RCslow reference. Starting from a PEEP level of 11 cmH2O PEEP-increasing and PEEP-decreasing steps were applied to the mechanically ventilated patients. Three out of ten patients with mild lung injury (30%) and 7/19 patients with ARDS (36.8%) revealed “slowly” distensible rscompartments in a PEEP-increasing step, whereas 15/19 ARDS patients and 1/10 patients with mild lung injury showed “slowly” distensible rs-compartments in a PEEP-decreasing step (78.9% vs 10%,P〈0.002, chi-square test). Conclusions The gas distribution properties of the respiratory system can be easily studied by a PEEP-step maneuver. The relative contribution of the “slow” units to the total increase of lung volume following a PEEP step could be adequately assessed. “Slowly” distensible rs-compartments could be detected in patients with severe and mild lung injury, however significantly more ARDS patients revealed “slow” rs-compartments in PEEP-decreasing steps. The influence of “slowly” distensible rs-compartments on pulmonary gas exchange is unknown and has yet to be studied.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-1238
    Keywords: Key words Respiration ; artificial instrumentation ; Heat and moisture exchanger ; Respiratory mechanics ; Pressure support ventilation ; P0.1 ; Feedback control
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To investigate the mechanical effects of artificial noses. Setting: A general intensive care unit of a university hospital. Patients: 10 patients in pressure support ventilation for acute respir
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    s.l. ; Stafa-Zurich, Switzerland
    Materials science forum Vol. 105-110 (Jan. 1992), p. 913-916 
    ISSN: 1662-9752
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...