Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 275 (1983), S. 80-85 
    ISSN: 1432-069X
    Keywords: Spillover ; T-cell subsets ; Monoclonal antibodies ; Immunoperoxidase ; Immunofluorescence techniques ; Allergic, toxic patch-test reactions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A strong positive, allergic patch-test reaction was elicited in 15 patients with an established allergy for a particular allergen. Patches with a marginally irritating concentration of sodium lauryl sulfate (SLS) were applied at fixed distances. The SLS patch situated adjacent to the allergic reaction was significantly enhanced in 12 of 15 patients (P〈0.01) compared to more distant SLS reactions (‘spillover’). Only quantitative differences were observed in the histologic pictures of the different types of reaction. The infiltrate consisted of lymphocytes and histiocytes, mainly located perivascular in the upper dermis. T-cell subsets were assessed with monoclonal antibodies using an immunoperoxidase technique. The distribution of the different T cells was the same for both reaction types. T cells located outside the perivascular infiltrates (e.g., in the epidermal vesicles) were OKT-8-positive (cytotoxic/suppressor T lymphocytes). Immunofluorescence examination did not show different patterns for the allergic or ‘enhanced toxic’ reactions with regard to the presence of immunoglobulins and complement. The ‘spillover’ phenomenon may cause falsepositive patch-test reactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 30 (1994), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Irritant reactions to sodium lauryl sulfate were induced on the backs of 20 volunteers by means of patch test occlusion for 24 h. Different concentrations ranging from 0.259% to 2% were used, the lowest concentration being borderline irritant. The skin tests were read at 24, 48 and 72 h. Both the % of responding individuals and the intensity of the skin reactions were maximal at 48 h for all test concentrations. It is concluded that irritants may provoke inflammatory reactions which are not completely developed after 24 h, and are thus very similar to allergic patch test reactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 7 (1981), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Irrelevant reactions occurred in 68 of 157 patients (43%) with strong positive patch test reactions and concomitant weak positive reactions. A lower figure, 13 of 45 (29%) was found in patients with only weak positive patch test reactions (0.1 〉 P 〉 0.05). An allergen eliciting a weak positive reaction should therefore be retested when a conclusion has to be drawn about the epidermal sensitivity of a patient.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 25 (1991), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 22 (1990), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Irritant contact dermatitis is common in metalworkers exposed to metalworking fluids (MWF). The irritancy of 3 commercially available water-based cutting fluids in maximal user's concentration and 2 neat oils was investigated in 23 healthy volunteers. Additionally, the irritancy of some groups of components of the cutting fluids was studied. After Sellotape® stripping, repeated patch tests were performed over 5 days and evaluated by a visual score (VS) and by laser Doppler flowtmetry (LDF). In general, the MWF caused marginal skin irritation. In a comparison of the MWF and water, the cutting fluids were ranked higher in irritancy than the neat oils, but the effect of only one cutting fluid could he distinguished from that of water. The components of the cutting fluids also caused no strong reactions, The LDF response showed than one emulsifier was more irritant than water and according to the VS, one corrosion inhibitor WHS the most irritant. The correlation coefficient between the VS and the LDF response was probably diminished by a strong adverse reaction to the fixing tape in many volunteers. From this experiment, it was concluded that MWF are generally only mildly irritant when used in proper concentrations. However, orthoergic contact dermatitis often develops as a result of repeated and cumulative subclinical insults, in which MWK especially water-based, play a crucial role because exposure at work is often extensive.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 21 (1989), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 24 (1991), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 20 (1989), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In an epidemiological study of 286 metalworkers exposed to metalworking fluids (MWF), the prevalence of contact sensitization was investigated. In part I, irritant contact dermatitis in metal workers has been discussed. In 40 employees with dermatitis, patch tests were performed with a routine series, a series of common components of MWF, and a series of preservatives the employees worked with. Contact sensitization was established in 8 persons (2.8% of all workers), of whom 4 were allergic to biocides and/or corrosion inhibitors. Difficulties in interpretation of the relevance of positive reactions are discussed. Attention is paid to the use of biocides in MWF, their various types and their sensitizing capacities. Measures to reduce the induction of contact sensitization to preservatives in water-based fluids are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 20 (1989), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In an epidemiological study of 286 metalworkers exposed to metalworking fluids (MWF), the prevalence of skin problems was investigated. Minor changes, such as a dry rough skin with slight erythema, were seen in 31%, and major changes, such as more serious and widespread dermatitis, were observed in 27% of all workers. By far the most cases were of irritant origin; in only 2.8% was a contact sensitization established. Exposure to water-based MWF caused irritant contact dermatitis more often than exposure to neat oils. No influence was found of the presence of atopy on the occurrence of dermatitis. Other factors that may result in irritation of the skin are discussed, as well as measures to be taken to minimize insult of the skin.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...