Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of medicinal chemistry 28 (1985), S. 992-996 
    ISSN: 1520-4804
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-0646
    Keywords: pharmacokinetics ; capecitabine ; 5-fluorouracil ; phase I trials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract An excretion balance and pharmacokinetic study was conducted in cancer patients with solid tumors who received a single oral dose of capecitabine of 2000 mg including 50 μ Ci of 14C-radiolabelled capecitabine. Blood, urine and fecal samples were collected until radioactive counts had fallen to below 50 dpm/mL in urine, and levels of intact drug and its metabolites were measured in plasma and urine by LC/MS-MS (mass spectrometry) and 19F-NMR (nuclear magnetic resonance) respectively. Based on the results of the 6 eligible patients enrolled, the dose was almost completely recovered in the urine (mean 95.5%, range 86–104% based on radioactivity measurements) over a period of 7 days after drug administration. Of this, 84% (range 71–95) was recovered in the first 12 hours. Over this time period, 2.64% (0.69–7.0) was collected in the feces. Over a collection period of 24–48h, a total of 84.2% (range 80–95) was recovered in the urine as the sum of the parent drug and measured metabolites (5′-DFCR, 5′-DFUR, 5-FU, FUH2, FUPA, FBAL). Based on the radioactivity measurements of drug-related material, absorption is rapid (tmax 0.25–1.5 hours) followed by a rapid biphasic decline. The parent drug is rapidly converted to 5-FU, which is present in low levels due to the rapid metabolism to FBAL, which has the longest half-life. There is a good correlation between the levels of radioactivity in the plasma and the levels of intact drug and the metabolites, suggesting that these represent the most abundant metabolites of capecitabine. The absorption of capecitabine is rapid and almost complete. The excretion of the intact drug and its metabolites is rapid and almost exclusively in the urine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 213-220 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Thermospray HPLC/MS analysis of the metabolites of arachidonic acid proved to be sensitive and specific. The compounds included were hydroxy-fatty acids (5-HETE, 12-HETE, and 15-HETE) and prostaglandins PGD2, PGE2, PGF2α, PGA2, PGA1, TXB2, and 6-Keto-PGF1α. Thermospray HPLC/MS analysis allows for simultaneous monitoring of each compound without the need for additional sample preparation or derivatization. The thermospray spectra for the metabolites exhibited [M + NH4]+ ions and fragment ions because of sequential loss of equivalents of H2O. HPLC/MS showed detection limits in the 0.5 to 5 ng range when using multiple ion detection for most of the metabolites. Post-column derivatization of these metabolites using trimethylanilinium hydroxide (TMAH) to form the methyl esters is also presented. This derivatization resulted in a gain in ion current by a factor of 3-6 for most compounds while adding potential specificity to the analysis. The thermospray spectra of the derivatives were nearly identical to the spectra of the free acid except the peaks were incremented by 14 daltons due to the methyl ester formation. The derivatization of the carboxylic acid group proved to be complete under thermospray conditions producing the maximum ion current and causing no compromise in operation of the interface.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 523-531 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Derivatization of prostaglandins and thromboxane B2 using diethyl amino ethyl chloride and diethyl amino ethyl bromide improved thermospray HPLC/MS sensitivity. The derivatization was evaluated for prostaglandin A1, A2, D2, E2, F1α, F2α, and thromboxane B2. The derivatization reaction, thermospray operating conditions, and mode of detection were optimized to produce the most intense [M + H]+ or [M - H]- ions for the derivative. Derivatization was better than 99% complete in 1 hour at 75°C. No thermal degradation of the prostaglandins was observed. Positive thermospray ionization proved the mode most sensitive, enabling detection from 10 to 300 pg of each prostaglandin under multiple ion detection. The thermospray spectra exhibited intense [M + H]+ ions for the derivative with a few fragment ions from sequential losses of water from the [M + H]+ ion. Detection of a prostaglandin metabolite in plasma over the concentration range from 3 ppm to 30 ppb was possible using this derivatization.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1980), S. 35-40 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A pseudoracemic technique utilizing a stable isotope in one enantiomer was employed for the simultaneous determination of (R) and (S)-warfarin from plasma of human subjects. The assay includes high performance liquid chromatographic clean-up prior to mass spectral analysis to eliminate ion interferences from either co-administered drugs or contamination of the source. The assay is reliable, accurate and precise to within 5% at the submicrogram level.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 8 (1981), S. 211-218 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A general equation is derived which is applicable to all problems of ion overlap between a stable isotope internal standard and a sample to be measured. The approach is then extended to solve the problem of ion overlap between three components. The equations are general in terms of all possible isotopic contributions. Utilization of the principle of fixed ion ratios within an ion cluster allows the algebraic solution of the problem such that the final equations are linear in form. It appears that linear regression can be used to calculate the coefficients of the linear equations without loss of accuracy or precision and with a significant reduction in the time and computation needs necessary for the analysis. This approach is compared and contrasted to those developed by other workers.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...