Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1912
    Keywords: HOE 498 ; Angiotensin converting enzyme inhibition ; Angiotensin II
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The converting enzyme inhibitor HOE 498 was evaluated in 12 normotensive male volunteers aged 21 to 26. The efficacy of single 5, 10 or 20 mg oral doses in blocking the pressor response to exogenous angiotensin I was tested in 3 of the subjects. All 3 doses of HOE 498 reduced the pressor response to exogenous angiotensin I to below 50% of control within 1,5 h following administration of the drug. Plasma renin and converting enzyme activity, blood angiotensin I, as well as plasma angiotensin II and aldosterone were measured serially before and up to 72 h following oral administration of a single dose of 2.5, 5, 10 or 20 mg of HOE 498 to groups of 5 volunteers each. As expected, blood angiotensin I levels and plasma renin activity rose while plasma converting enzyme activity, plasma angiotensin II and aldosterone concentration fell after administration of the drug. While the dose of 2.5 mg did not reduce plasma converting enzyme activity below 20% of control, the higher doses all resulted in plasma converting enzyme inhibition exceeding 90%. No side-effects were observed. It is concluded that in normal volunteers HOE 498 is an effective potent and long-acting converting enzyme inhibitor. Based on these preliminary findings it is expected that 5 mg HOE 948 will turn out to be adequate for therapeutic use.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: converting enzyme inhibitor ; CGS 14824A ; pharmacodynamics ; plasma renin ; plasma angiotensin ; aldosterone ; side-effects ; healthy volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The converting enzyme inhibitor CGS 14824A was evaluated in 15 healthy male volunteers. First, the efficacy of a single 5 or 10 mg oral dose in antagonizing the pressor response to exogenous angiotensin I was tested in 2 subjects. Blood pressure and heart rate were monitored continuously through an intra-arterial catheter. CGS 14824A 5 mg reduced the response to angiotensin I within 75 min to 50%, and 10 mg within 1 h to less than 25%, and for a period of more than 4 h. Subsequently, plasma renin and converting enzyme activity, plasma angiotensin I, angiotensin II and aldosterone were measured serially before and up to 72 h following oral administration of 2, 5, 10 or 20 mg CGS 14824A to groups of 5 volunteers. Plasma converting enzyme activity fell to well below 10% of baseline within 1 h after administration of 5 mg or more CGS 14824 A. Within 2 h following 2 mg p.o., a similarly low level was reached. Twenty four hours following the 20 mg dose, plasma converting enzyme activity was still below 10%. As expected, plasma renin activity and angiotensin I rose while angiotensin II and aldosterone fell following the 2 mg dose. This pattern of effects was enhanced by increasing the dose. Nonetheless, 24 h after the 20 mg dose, plasma angiotensin II and aldosterone had returned to their baseline levels. No side-effects occurred. Thus, in normal volunteers, CGS 14824A was an effective, potent and long acting converting enzyme inhibitor.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...