    ISSN: 0935-6304
    Keywords: Trace analysis ; Gas chromatography ; Solvent effect ; Inlet ; Injector ; Sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A sampling system for high resolution gas-liquid chromatography, based on the dynamic solvent effect, is described. Volatiles are accumulated off-line in a concentrator/injector and delivered to the column using an on-line inlet. Volatiles may be accumulated from gaseous or liquid matrices; they may be transferred to these by gas sparging or solvent extraction of any type of sample. The sampling technique is quantitatively precise; e.g. coefficients of variation of peak percentage areas better than 5% for a range of solutes at a concentration of 2:107. Examples of the application of the sampling system are presented.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 521-524 
    ISSN: 0935-6304
    Keywords: Derivatization ; Trimethylsilyl ; Dynamic solvent effect ; Headspace ; Apis mellifera ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the derivatization of volatiles collected using the dynamic solvent effect (DSE) is described. Trimethylsily ethers and esters (using N,O-bis-trimethylsilyltrifluoracetamide) are produced on the porous bed of a DSE concentrator either during or after collection of airborne volatiles. Peak areas obtained in the gas chromatographic analysis of test compounds gave coefficients of variation of less than 10% for amounts considerably less than 100 ng. Little, if any, adsorption or other loss of compounds occurs. The analysis of the volatiles collected from an individual queen of the honeybee, Apis mellifera scutellata, is presented to illustrate the utility of the technique.