Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 1067-1067 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A high-current, high-energy, and long-pulse positive ion source for the KSTAR neutral beam system is being developed on the basis of proven technology. The original prototype ion source was the TFTR developed by LBNL, but the accelerator slit grid brazed with shaped molybdenum tubes was a barrier for success of the copied work. In order to cover the technical and economical problems caused by the molybdenum tubes, a new OFH copper grid with circular apertures has been designed and manufactured. Cooling circuits aligned along every line of the aperture arrays are made with the help of gun drills. The test and the first experimental results of the upgraded ion source, such as high-voltage characteristics, cooling characteristics, discharge characteristics, and first beam extraction characteristics are described. © 2002 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: In order to assess endogenous and colonic production of acetate, we have developed an assay for determining the isotopic enrichment of plasma acetate using gas chromatography/mass spectrometry (GC/MS). Acidified, deproteinized plasma (200 μl) was extracted into ethyl ether, and the ether phase was then injected into a gas chromatograph/mass spectrometer fitted with a 30 m × 0.252 mm i.d. capillary column (temperature program 50-245°C at 10°C min-1). Using electron impact GC/MS and selected ion monitoring, peak areas of ions with m/z 60 and 61 (M + 1) were determined. Triplicate extractions of enriched plasma samples (mol.% excess 1.38-1.5%) resulted in a coefficient of variation of 1.6-5.9%. Unenriched plasma samples were found to have an enrichment close to theoretical natural abundance, and analysis of our (1-13C)acetate tracer (99 at.% excess) revealed an ion at m/z 61 and no ion at m/z 60. To verify accuracy, we conducted an in vivo isotope dilution study. In a 1-month-old piglet, fasted for 24 h, changing the rate of a 4 h infusion (mmol h-1) of (1-13C)acetate from 0.141 to 0.282 doubled the isotope enrichment (2.08 x) of the second plateau. The rate of appearance of acetate was 26.0 μmol kg-1 min -1, which is comparable to that reported in fasting sheep.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...