    ISSN: 1573-7217
    Keywords: axillary lymphnode metastasis ; breast cancer ; 111In-pentetreotide ; receptor autoradiography ; somatostatin receptors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We conducted a prospective analysis of somatostatin receptor scintigraphy using 111In radiolabeled pentetreotide, a somatostatin analog, in patients with breast cancer in the aim to visualize the primary tumor and axillary or parasternal metastatic extension because some malignant breast tumors express somatostatin receptors (SS-R) in 50%, approximately. An analysis of SS-R was performed by autoradiography. Patients and methods.Thirteen patients with clinically suspected breast tumors (T1, T2), and at least one palpable axillary node (N1) were included. In vivo planar scintigrams were acquired 1, 4, and 24 h after subcutaneous, then after intravenous injections (24 h delay between injections). Improved 111In-pentetreotide uptake in invaded nodes after subcutaneous injection was hypothesized. Ex vivo scintigrams of surgical specimens were also acquired immediately after tumor resection and axillary dissection. Pathological examination and receptor autoradiography were performed on all surgical specimens. Results.Among 11 pathologically proven malignant tumors (9 ductal and 2 lobular carcinomas), only four were scintigraphically visible although six expressed SS-R receptors in vitro. Among six pathologically proven malignant nodes, four expressed SS-R, including two visualized scintigraphically. Scintigrams acquired after subcutaneous injections were less sensitive than after intravenous injections. There were no false positive. False negatives occurred in cases with small tumors with low-density or heterogeneously distributed SS-R. There was no significant difference by histological type or prognostic factors. Conclusion.Somatostatin receptor scintigraphy does not appear to be sensitive enough to evaluate axillary node extension of breast cancer or even to confirm the presence of tumoral tissue, and this whatever the administration route for 111In-pentetreotide.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-2568
    Keywords: Crohn's disease ; isotope scanning ; colonoscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this study was to determine whether the sensitivity of indium-111 (111In) scanning in the assessment of the activity and extent of Crohn's disease correlates with the severity of intestinal lesions as measured by the newly validated Crohn's disease endoscopic index of severity (CDEIS). Nineteen patients with active (CDAI〉200) colonic (N=11) or ileocolonic (N=8) Crohn's disease were assessed by colonoscopy and indium scanning. The intestine was divided into five segments in both studies (rectum, sigmoid and left colon, transverse colon, right colon, and ileum). Seventy of the 86 intestinal segments seen at colonoscopy presented macroscopic lesions of Crohn's disease. On third-hour scintigrams111In uptake was observed in 52 segments, 51 of which were found to be abnormal at colonoscopy. Predictive positive and negative values of scanning with respect to disease extent assessment were equal to 98% and 44%, respectively. Complete agreement between endoscopic and scintigraphic findings was observed in only six of the 19 patients (32%). Segmental endoscopic indexes of severity (SEIS) were significantly (P〈0.001) lower in false negative (7.9±4.2) (mean ±sd) than in true positive (18.0±9.7) segments as defined by scintigraphy. SEIS values above which111In uptake was constantly observed did not differ in the different disease locations. When comparing macroscopically abnormal intestinal segments according to their111In uptake grade, the corresponding mean SEIS values increased significantly as the grade increased. Scintigraphic activity, as assessed by the fall in splenic activity, was equal to 23±11% (N=19). It correlated significantly with CDEIS (r=0.63,P〈0.005), but even more so when the highest SEIS of each patient had been taken into account (r=0.75,P〈0.0005). In conclusion, when considering disease extent and activity, scanning results correlate well with the endoscopic severity of intestinal lesions in active Crohn's disease. Nevertheless, minor endoscopic lesions can be missed by111In scanning.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...