Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 45 (1990), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Six Engström Elsa anaesthetic machines have been in regular use for 18–24 months. The machine incorporates a number of new concepts for anaesthetic delivery and monitoring. At flows below 1000 ml/minute, each machine delivered 20% more than the indicated value; at higher flows, the indicated value was within 10% of the flow delivered. Minute volume, tidal volumes and oxygen concentrations were within the manufacturer's specifications. However, vaporizer and vapour monitor performance was outside the (SD) 5% accuracy claimed by the manufacturers. It was noted that the bistable valve requires user familiarity for the change from controlled to spontaneous ventilation to be accomplished with ease. It was also possible to misconnect the breathing system and so isolate the excess pressure escape valve and high-pressure alarm. Nevertheless, once familiarisation was achieved, the machines have proved easy to operate and are particularly satisfactory when used with low fresh gas flows.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Digestive diseases and sciences 32 (1987), S. 121-128 
    ISSN: 1573-2568
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We tested a manometric assembly employing a sleeve sensor that is able to monitor anterior or posterior pressure in the human upper esophageal sphincter (UES) for prolonged intervals. When compared to rapid pull-through measurement of UES pressure obtained with conventional manometric assemblies, the sleeve sensor measured significantly lower UES pressures with less variability between subjects, thereby suggesting that the rapid pull-through maneuver stimulates the UES to contract. Concurrent recordings of UES pressure with a sleeve sensor and a side-hole sensor during a slow station pull-through yielded almost equal pressure values at the peak of the high-pressure zone (station zero), but the side-hole site recorded significantly lower pressures than the sleeve at stations 0.5 cm or more from the peak of the high-pressure zone. During 10 min of recording at station zero, the sleeve sensor recorded greater pressures than the side-hole sensor. This finding demonstrated the suceptibility of the side-hole sensor to axial movement relative to peak UES pressure. When stationary, both the sleeve sensor and the side-hole sensor recorded significantly lower UES pressure after 1–2 min of recording, again suggesting that movement of the recording assembly stimulates the UES to contract. Sleeve recordings of swallow-induced UES relaxations showed that UES relaxations induced by water swallows were slightly longer than those induced by dry swallows. Augmentations of UES pressure induced by balloon distension of the esophageal body were also recorded. We conclude that the sleeve sensor is a suitable method for investigating the normal physiology and pathophysiology of the UES in human subjects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-2568
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We report a 45-year-old nonalcoholic patient with Von Recklinghausen's disease and chronic recurrent pancreatitis. On endoscopy, a benign-appearing submucosal tumor surrounded the papilla of Vater. Cannulation of the pancreatic duct showed a dilated ductal system with subsequent delayed drainage. Endoscopic manometry revealed elevated sphincter of Oddi pressures. Endoscopic sphincterotomy resulted in immediate normal drainage of the pancreatic duct and in subsequent clinical improvement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-2568
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Digestive diseases and sciences 21 (1976), S. 44-46 
    ISSN: 1573-2568
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...