Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Pharmaceutical and Biomedical Analysis 3 (1985), S. 227-234 
    ISSN: 0731-7085
    Keywords: Digoxin ; amorphous forms ; dissolution rate. ; physicochemical characteristics ; polymorphs ; solid-state properties
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 33 (1977), S. 2739-2743 
    ISSN: 1600-5740
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 66 (1976), S. 403-409 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Existenz einer zweiten, polymorphen Modifikation des Androsterons wurde bestätigt. Deren thermoanalytische und kristallographische Merkmale wurden durch differentielle Enthalpiebestimmung sowie durch Röntgenbeugungsanalyse ermittelt. Erhöhung der Temperatur auf 165° C, Verreiben der Substanz oder längere Aufbewahrung bei Zimmertemperatur führen zur Rückbildung der stabileren Modifikation I.
    Abstract: Summary The existence of a second polymorphic form of androsterone has been confirmed. The thermoanalytical and crystallographical characteristics of this form II were determined by differential enthalpic analysis and X-ray diffraction analysis. Raising the temperature to 165° C, trituration or prolonged maintenance at ambient temperature regenerates the more stable form I.
    Notes: Résumé L'existence d'une deuxième forme polymorphe de l'androstérone est confirmée. Les caractéristiques thermoanalytiques et cristallographiques de cette forme II ont été déterminées par analyse enthalpique différentielle et analyse par diffraction des rayons X. L'élévation de la température à 165° C, le broyage ou le maintien prolongé à température ambiante régénèrent la forme I, plus stable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Nach einer Übersicht der üblichen Methoden der Linearisierung der Beziehung $$T_{Fi} = f(1/Fi)$$ für die Reinheitsbestimmung mittels Differentialmikrocalorimetrie wird eine neue, nicht iterative Methode beschrieben und diskutiert.
    Abstract: Summary A critical review of the $$T_{Fi} = f(1/Fi)$$ plot linearization methods in purity determinations by differential scanning calorimetry is presented. A new, non iterative, linearization method is described and discussed.
    Notes: Résumé Après une revue des méthodes utilisées pour linéariser la relation $$T_{Fi} = f(1/Fi)$$ lors des déterminations de pureté par micro-calorimétrie différentielle, une nouvelle méthode, non itérative est décrite et discutée.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 67 (1977), S. 511-519 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Drei kristalline Formen des 5-alpha-Androstan-3,17-dions wurden nachgewiesen und durch différentielle Enthalpiemessung, Infrarotspektrophoto-metrie und Röntgendiffraktionsmessung charakterisiert, nämlich die am häufigsten auftretende Form I, die unbeständige Form II und die bisher nicht beschriebene, pseudopolymorphe Form III, das Androstadion:4H2O:1.
    Abstract: Summary Three crystalline forms of androstadione (5α-androstane-3,17dione) were pointed out and characterized by differential scanning calorimetry, infrared spectrophotometry and X-ray diffraction analysis: form I, the most frequent, form II, instable, and form III, not yet described, a pseudopolymorphe one: androstadione 4-H2O:1.
    Notes: Résumé Trois formes cristallines de l'androstadione (5α-androstane-3,17-dione) ont été mises en évidence et caractérisées par analyse enthal-pique differentielle, spectrophotométrie infrarouge et analyse par diffraction de rayons X: La forme I, la plus fréquemment rencontrée. La forme II, instable. La forme III, non décrite, pseudopolymorphe: androstadione: 4-H2O: 1.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 20 (1981), S. 141-146 
    ISSN: 1572-8943
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Résumé La détermination de la pureté par DSC est dérivée de la méthode cryoscopique. La principale difficulté réside dans l'absence de linéarité de la relation expérimentaleT i=f(1/F i) et dans la correction qu'elle implique. Compte tenu de cette situation, une méthode de calcul basée sur l'analyse mathématique de la relation expérimentale est proposée, discutée et illustrée.
    Abstract: Zusammenfassung Die Reinheitsbestimmung durch DSC wird von der kryoskopischen Methode abgeleitet. Die grösste Schwierigkeit besteht in der Krümmung der experimentellen Funktion Ti=f(1/F i) und in der erforderlichen Korrektur. Unter dieser Berücksichtigung wird eine auf der mathematischen Analyse des experimentellen Zusammenhanges beruhende Berechnungsmethode vorgeschlagen, diskutiert und veranschaulicht.
    Notes: Abstract Purity determination by DSC is based on the cryoscopic method. The main difficulty lies in the curvature of theT i=f(1/F i,) experimental plot and in the necessary corrections. Taking this situation into account, a method of calculation based on mathematical analysis of the experimental relation is proposed, discussed and illustrated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...