Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 66 (1994), S. 2116-2128 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 66 (1994), S. 2686-2693 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Chirality 10 (1998), S. 375-381 
    ISSN: 0899-0042
    Keywords: retention mechanisms ; separation of enantiomers ; chiral stationary phases ; equilibrium isotherms ; bonding ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The retention mechanisms and the separation of enantiomers on the classes of chiral stationary phases which are made by bonding isolated groups on the surface of an adsorbent are discussed. It is shown that retention on these phases originates from mixed mechanisms and how the individual contributions of these two mechanisms can be separated, by determining and modeling the equilibrium isotherms. A contribution originating from interactions of the isomers with the nonselective sites (type-I) and another one due to interactions with the enantioselective sites (type-II) can be determined and their importance studied as a function of several parameters, e.g., temperature or pH. This approach is illustrated with results obtained with different pairs of enantiomers on bovine serum albumin, 4-methylcellulose tribenzoate, or cellobiohydrolase immobilized on silica. Chirality 10:375-381, 1998. © 1998 Wiley-Liss, Inc.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Chirality 9 (1997), S. 329-334 
    ISSN: 0899-0042
    Keywords: atenolol ; enantiomers ; liquid chromatography ; cellobiohydrolase I ; chiral CBH ; coupled-columns ; cellobiose ; peak compression ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two different enantioselective chiral chromatographic methods were developed and validated to investigate the disposition of the β1-receptor antagonist atenolol in blood and in brain extracellular fluid of rats (tissue dialysates). System A for the plasma samples was a one-column chromatographic system with a Chiral CBH column with an aqueous buffer as mobile phase into which cellobiose was added for selective regulation of the retention of the internal standard, (S)-metoprolol. The plasma samples were analysed after a simple extraction procedure. The limit of quantitation was 0.2 μg/ml for the atenolol enantiomers. The repeatability of the medium concentration quality control plasma sample (6.0 μg rac-atenolol/ml) was 11-18% for the enantiomers. The dynamic linear range of the plasma samples was 0.5-20 μg/ml. For system B, since atenolol is an extremely hydrophilic drug, the tissue dialysate sample required a much more sensitive system as compared to the plasma samples. A coupled column system was used for peak compression of the enantiomers in the eluate after the separation on the Chiral CBH column, hence increasing the detection sensitivity. The limit of quantification was 0.045 μg/ml for the atenolol enantiomers in artificial CSF. The repeatability of the medium concentration quality control samples (0.1 and 4.0 μg rac-atenolol/ml in artificial CSF and Hepes Ringer, respectively) was 2.8-9.3% for the two enantiomers. The dynamic linear range of the brain samples was 0.05-1.0 and 0.5-20 μg/ml in artificial CSF and Hepes Ringer, respectively. Chirality 9:329-334, 1997. © 1997 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...