Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Mapping of Atrial Fibrillation. Introduction: Long linear lesions have been shown to eliminate atrial fibrillation in animal models, but little is known about the electrophysiologic response in one atrium to lesions in the contralateral atrium. Methods and Results: Twelve dogs with chronic atrial fibrillation were randomized to either right atrial ablation (n = 4), left atrial ablation first (n = 4), or a sham procedure (n = 4). Simultaneous biatrial endocardial mapping was performed before and after three linear lesions were applied at specific points in either atrium, using an expandable ablation catheter. Atrial fibrillation was reinducible after single atrial ablation in each dog and no longer inducible after biatrial ablation in five dogs. At baseline, the mean atrial fibrillation cycle length was longer on the trabeculated (117 ± 15 msec) compared with the smooth right (101 ± 16 msec) or left atrium (88 ± 10 msec; P 〈 0.01). Single right and left atrial ablation caused a significant cycle length increase in the ablated atrium. Left atrial ablation increased the cycle length on both the trabeculated (121 ± 18 msec vs 137 ± 11 msec; P 〈 0.05) and smooth right atrium (108 ± 12 msec vs 124 ± 9 msec; P 〈 0.05). Right atrial ablation, however, had no significant effect on left atrial fibrillation cycle length (82 ± 8 msec vs 86 ± 7 msec). Conclusion: Left atrial linear lesions affect right atrial endocardial activation, whereas right atrial lesions do not affect left atrial activation in a canine model of atrial fibrillation. These findings suggest that the left atrium is the driver during chronic atrial fibrillation in this animal model and may explain the limited success of right atrial ablation alone in human atrial fibrillation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Prediction of Left Atrial Linear Lesions. Introduction: Continuity of radiofrequency (RF) lesions for a catheter-based cure of atrial fibrillation is essential in order to avoid reentrant tachycardias. In the present study, we assessed the value of intracardiac echocardiography and preablation electrode-tissue interface parameters for creation of left atrial linear lesions. Methods and Results: In six healthy dogs, two left atrial linear lesions (lesion 1, along the inferior posterior left atrium; lesion 2, from the appendage to the left atrial roof) were attempted via a transseptal approach using a deflectable catheter with six 7-mm coil electrodes. In a randomized fashion, one lesion was performed under echocardiographic guidance and one with blinded echocardiographic monitoring. The following preablation parameters were assessed for every coil electrode: (1) mean atrial electrogram amplitude of six consecutive sinus beats; (2) diastolic pacing threshold; and (3) temperature response to application of 5 W for 10 seconds. After ablation (target temperature 70°C, maximum power 50 W, duration 60 sec), the excised left atrium was examined macroscopically and histologically for lesion length, continuity, and presence or absence of lesions associated with each coil.Out of 12 attempted RF lesions, 7 were continuous (length, 47 ± 5 mm, lesion 2, n = 6) and 5 were discontinuous (lesion 1, n = 5). Fifty-two of 70 coil electrodes (74%) had pathologic evidence of lesion creation. Intracardiac echocardiography was superior to fluoroscopy with respect to the actual number of coil electrodes creating lesions, and lesion continuity was correctly predicted in 9 of 12 lesions. Intracardiac echocardiography was 85% sensitive and 54% specific in predicting lesions created by individual coils. The correlation between the mean 60-second ablation temperature and the preablation parameters was 0.45 for the electrogram amplitude, -0.67 for the pacing threshold, and 0.81 for the temperature response to low-power application. Sensitivity and specificity for prediction of lesions created by individual coils, respectively, were 84% and 48% for the electrogram amplitude. 90% and 68% for the pacing threshold, and 96% and 76% for the low-power RF application. Conclusion: Long linear lesions can be safely and effectively performed in the canine left atrium, using a tip-deflectable multielectrode catheter. Intracardiac echocardiography may be helpful for positioning the ablation catheter in some parts of the left atrium, and preablation parameters, especially a nontraumatic low-power RF application, are able to predict ultimate lesion creation with high accuracy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Catheter Ablation for Mahaim Pathways. Introduction: Several modalities of catheter ablation have been proposed to eliminate Mahaim pathway conduction. However, limited research has been reported on the electrophysiologic nature of this pathway in its entity. Methods and Results: In seven patients, electrophysiologic study was performed, and radiofrequency energy was applied to investigate the electrophysiologic clues for successful ablation. In all seven patients, the Mahaim pathway was diagnosed as a right-sided atriofascicular or atrioventricular pathway with decremental properties. In two patients, two different kinds of electrograms were recorded through the ablation catheter positioned at the Mahaim pathway location: one was suggestive of conduction over the decremental portion, demonstrating a dulled potential; and the other of nondecremental conduction, demonstrating a spiked potential. All but one of the Mahaim pathways were eliminated successfully at the atrial origin where the spiked Mahaim potential was recorded. Radiofrequency energy application was performed at the slow potential site resulting in failure to eliminate the conduction over the Mahaim pathway. Conduction block at the site between the slow and fast potential recording sites was provoked by intravenous administration of adenosine, concomitant with a decrease in the amplitude of the Mahaim potential. In one patient, the clinical arrhythmia was a sustained monomorphic ventricular tachycardia originating from the ventricular end of the Mahaim fiber. Conclusion: The identification of Mahaim spiked potentials may be the optimal method to permit their successful ablation. Detailed electrophysiologic assessment is indispensable for successful ablation of tachycardias associated with Mahaim fibers because tachycardias unassociated with Mahaim fibers can occur despite complete elimination of the Mahaim fiber.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Slow A V nodal pathway ablation using RF is highly effective for patients with refractory A V nodal reentrant tachycardia (AVNRT). We report three catheter ablation cases using RF current in patients associated with persistent left superior vena cava (PLSVC). Three patients with drug refractory AVNHT of common variety were involved in this study. An electrode catheter introduced through the left subclavian vein inserted directly into the coronary sinus, a typical anatomical finding of PLSVC. The ablation procedure was initially performed at the posteroinferior region of Koch's triangle. A slow pathway potential could not be found from that area; nonsustained junctional tachycardia (NSJT) did not occur during the delivery of RF current; there was failure to eliminate slow AV nodal pathway conduction. The catheter then was moved into the bed of the proximal portion of the markedly enlarged coronary sinus. A slow AV nodal pathway potential was recorded through the ablation catheter, and the delivery of RF current caused NSJT in two patients. Complete elimination of slow AV nodal pathway conduction was accomplished in these two patients by this method. No adverse effects were provoked by this procedure. Catheter ablation of the slow A V nodal pathway guided by a slow pathway potential and the appearance of NSJT was feasible and safe in the area of the coronary sinus ostium in patients associated with PLSVC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: 62-Lead QRST Subtraction Algorithm. Introduction: Atrial activity on the surface ECG during premature beats and supraventricular arrhythmias frequently is obscured by the superimposed QRST complex of the previous cardiac cycle. This study examines the performance of a newly developed automatic QRST subtraction algorithm to isolate ectopic P waves from the preceding T-U wave. Methods and Results: The 62-lead ECG recordings were obtained during (1) sinus rhythm and programmed right atrial stimulation in 12 patients (group A); and (2) sinus rhythm and atrial premature beats, atrial tachycardia, or paroxysmal atrial fibrillation in 5 patients (group B). Pacing in group A patients was conducted at a slow drive cycle length to generate an ectopic P wave not obscured by the previous QRST complex and by delivering single premature extrastimuli at progressively shorter coupling intervals to produce an ectopic P wave obscured by the upsloping (early T-U wave), peak (middle T-U wave), and downsloping component of the T-U wave (late T-U wave). All ectopic P waves in group B patients were concealed by the preceding T-U wave. Automatic QRST subtraction was attained using an adaptive template constructed from averaged QRST complexes (mean 83 ± 25 complexes) obtained during sinus rhythm (groups A and B) or atrial overdrive pacing (group A). P wave integral maps subsequently were computed, visually compared, and mathematically correlated. A high correspondence in spatial map pattern was observed between integral maps of “nonobscured” and previously “obscured” paced P waves obtained in group A patients (mean r = 0.88 ± 0.07) as well as between integral maps of two to three previously obscured P waves with the same atrial arrhythmia morphology obtained in group B patients (mean r = 0.94 ± 0.05). Improved morphologic P wave replication in group A patients was acquired when concealment occurred in the early (mean r = 0.90 ± 0.08) or late part of the T-U wave (mean r = 0.90 ± 0.06) as opposed to the middle T-U wave (mean r = 0.85 ± 0.07) (P = NS and P 〈 0.05 for early vs middle and late vs middle T-U wave, respectively). Conclusion: This novel automatic 62-lead QRST subtraction algorithm enables discrete isolation of T-U wave obscured ectopic atrial activity on the surface ECG while retaining the intricate spatial detail in P wave morphology. Future clinical application of the algorithm may enable improved ECG localization of focal triggers of paroxysmal atrial fibrillation, atrial tachycardia, and the atrial insertion of accessory pathways.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1572-8595
    Keywords: ablation ; atrial fibrillation ; ultrasound ; pulmonary vein ; technology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...