Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 27 (1984), S. 51-56 
    ISSN: 1432-1041
    Keywords: fentanyl ; cardiac surgery ; fentanyl plasma concentration ; fentanyl sequestration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Immediately following the connection of pediatric patients to cardiopulmonary bypass we have consistently observed a steep decrease in fentanyl plasma concentration (74±8.7%) (mean±SD), much greater than would have been expected from hemodilution alone (50.6%±12.0%) (p〈0.0001). Priming of the pump with 20 ng/ml of fentanyl before connection to the patients did not prevent this phenomenon. In order to study the possibility that fentanyl is sequestered by the bypass, levels of the primed drug in the bypass were assessed before connecting the pump to the children and a steep fall from 20 ng/ml to zero was shown before initiation of bypass. Pharmacokinetic assessment of fentanyl in a closed pump circuit showed that levels of 120 ng/ml fall to 2 ng/ml within 3 min and remain stable at the lower concentration for at least 30 min. Further studies have identified the membrane oxygenator as the major site of fentanyl sequestration. Concentrations across the membrane fall from 120 ng/ml to 10 ng/ml. The attached siliconized tubing is associated with a minor binding effect sufficient to reduce concentrations from 110 to 84 ng/ml. The pvc tubing, aluminium heat exchanger and plastic reservoir had no binding effect on fentanyl. The possibility that a decrease in fentanyl protein binding caused the fall in serum concentration was checked in 5 patients undergoing open heart surgery. After initiation of the cardiopulmonary bypass, there was a significant decrease in albumin serum concentrations from 32.0±2.3 mM to 15.0±1.6 mM (p〈0.0001). Since this decrease is identical to the dilutional effect anticipated on initiation of bypass, it is unlikely that there was any change in free fentanyl concentration from that observed in the prebypass period.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 27 (1984), S. 51-56 
    ISSN: 1432-1041
    Keywords: fentanyl ; cardiac surgery ; fentanyl plasma concentration ; fentanyl sequestration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Immediately following the connection of pediatric patients to cardiopulmonary bypass we have consistently observed a steep decrease in fentanyl plasma concentration (74±8.7%) (mean±SD), much greater than would have been expected from hemodilution alone (50.6%±12.0%) (p〈0.0001). Priming of the pump with 20 ng/ml of fentanyl before connection to the patients did not prevent this phenomenon. In order to study the possibility that fentanyl is sequestered by the bypass, levels of the primed drug in the bypass were assessed before connecting the pump to the children and a steep fall from 20 ng/ml to zero was shown before initiation of bypass. Pharmacokinetic assessment of fentanyl in a closed pump circuit showed that levels of 120 ng/ml fall to 2 ng/ml within 3 min and remain stable at the lower concentration for at least 30 min. Further studies have identified the membrane oxygenator as the major site of fentanyl sequestration. Concentrations across the membrane fall from 120 ng/ml to 10 ng/ml. The attached siliconized tubing is associated with a minor binding effect sufficient to reduce concentrations from 110 to 84 ng/ml. The pvc tubing, aluminium heat exchanger and plastic reservoir had no binding effect on fentanyl. The possibility that a decrease in fentanyl protein binding caused the fall in serum concentration was checked in 5 patients undergoing open heart surgery. After initiation of the cardiopulmonary bypass, there was a significant decrease in albumin serum concentrations from 32.0±2.3 mM to 15.0±1.6 mM (p〈0.0001). Since this decrease is identical to the dilutional effect anticipated on initiation of bypass, it is unlikely that there was any change in free fentanyl concentration from that observed in the prebypass period.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1041
    Keywords: hypothermia ; fentanyl ; pharmacokinetics ; cardiopulmonary bypass ; hypothermia-induced hypoperfusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The effect of hypothermia on the disposition of fentanyl was evaluated in 18 children undergoing corrective cardiac surgery. They received a bolus of fentanyl followed by a continuous infusion which was stopped when cardiopulmonary bypass was established and profound hypothermia was achieved (18 °C–25 °C). Fentanyl plasma concentration remained essentially unchanged during hypothermia (6.45 ng/ml 5 min into hypothermia and 5.26 ng/ml 100–140 min later; p〉0.1). In subsequent experiments, the effect of hypothermia on the pharmacokinetics of fentanyl was studied in 4 piglets serving as their own controls. Both distribution volume (Vz) and total body clearance (CL) were significantly smaller during hypothermia. Our studies indicate that being a drug with a large distribution volume and a high hepatic extraction ratio, both CL and Vz are significantly reduced by hypothermia-induced hypoperfusion. In addition, TBC is influenced by the temperature-dependent hepatic metabolism of fentanyl.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...