Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 85 (1999), S. 5387-5389 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: The magnetic and structural properties of the bulk manganite Eu2/3Ca1/3MnO3 are characterized using Mössbauer spectroscopy, magnetization measurements, x-ray diffraction, and resistivity measurements. Here it is demonstrated that one can investigate the magnetic properties of manganites using Mössbauer spectroscopy by doping with europium at the rare earth site and using rays from Eu151 as a probe. Mössbauer measurements were performed at several temperatures between 15 and 293 K using a 151Eu source. The spectrum at room temperature is a single line demonstrating paramagnetism with an isomer shift of 0.60±0.02 mm/s. Measurements at room temperature show the Eu to be trivalent and single phase with a linewidth of 2.933±0.004 mm/s, which is comparable to that found for the Mössbauer standard EuF3. Measurements below 100 K show a much broader linewidth which at 15 K is more than twice that found at 293 K and is associated with a magnetic phase transition. Magnetization as a function of magnetic field measurements up to 5 T show the system to be paramagnetic at 300 K and ferromagnetic-like at 50 K. Magnetic susceptibility measurements made between 300 and 4.2 K show the sample to be paramagnetic down to 100 K, where it undergoes a magnetic phase transition. Mössbauer, resistivity, and magnetic measurements all indicate a change in the paramagnetic state around 230 K. © 1999 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 24 (1969), S. 0 
    ISSN: 1365-2044
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 39 (1984), S. 0 
    ISSN: 1365-2044
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: This study was designed to assess the effect of time on the analgesic effect of a local anaesthetic cream consisting of a mixture of 5% lignocaine and prilocaine. The cream and placebo were compared in a double-blind, randomized study in 114 children aged 4–17 years, with application times of 20 minutes and longer. A regression analysis revealed no difference in analgesic effect between cream and placebo when application times were less than 60 minutes. A cusum test showed that the effect of the cream became evident at about 60 minutes. Local adverse reactions consisted mainly of transient paleness of the skin, which did not constitute any clinical problem.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    European journal of clinical pharmacology 34 (1988), S. 291-297 
    ISSN: 1432-1041
    Schlagwort(e): terodiline ; elderly patients ; pharmacokinetics
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Medizin
    Notizen: Summary As a target group, geriataric patients were selected for pharmacokinetic studies with terodiline (Mictrol), an anticholinergic and calcium antagonist drug effective in the treatment of urinary incontinence. The single-dose kinetics in the geriatric patients (mean age 82 years) differed significantly from that previously found (Hallén et al. 1987) in healthy volunteers (mean age 35 years). There were higher peak serum concentrations (110 vs 79 µg·l−1), increased half-life (189 vs 60 h), lower renal clearance (4.0 vs 10.9 ml·min−1) and lower total clearance (29 vs 75 ml·min−1). Multiple-doses of 12.5 mg b.d. for 6–8 weeks resulted in a mean steady-state concentration of 642 µg·l−1, which was in agreement with the single dose parameters. The studied geriatric patients can be characterized not only as old, but also as frail, bedridden, having several diseases and polymedicated. The differences in pharmacokinetics between younger and elderly subjects can be attributed to a variety of complex factors, which may alter the clearance and/or the volume of distribution.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1432-1041
    Schlagwort(e): terodiline ; elderly patients ; metabolites ; pharmacokinetics ; side-effects
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Medizin
    Notizen: Summary The elderly form an important target group for the treatment of urinary urge incontinence with drugs such as terodiline (Mictrol, Terolin). In order to evaluate its steady-state pharmacokinetics and tolerability in geriatric patients terodiline 12.5 mg b.d. was given to 28 hospitalized patients with urinary incontinence (mean age 85 years) for six weeks. The patients were monitored during the study and for 6 weeks afterwards, blood samples being taken at regular intervals. In addition to these multi-diseased and polymedicated patients, a small, homogenous group of healthy volunteers (mean age 40 years) was studied as a reference group, being given terodiline 12.5 mg b.d. for 2 weeks. Terodiline was generally well tolerated by the patients and no significant change in blood pressure or heart rate were found. One patient was withdrawn due to adverse effects. The mean terminal half-life of terodiline was 131 h and the clearance after oral administration (clearance/systemic availability) was 39 ml·min−1. The corresponding figures for the healthy volunteers were 57 h and 75 ml·min−1. The average steady-state serum concentration was 518 µg·l−1 in the geriatric patients and 238 µg·l−1 in the healthy volunteers. Steady-state was reached within 3 weeks in 20 of the 28 patients and within 5 weeks in 7 patients. In the geriatric patients the steady-state serum concentration of the main metabolite p-hydroxyterodiline, during the last three weeks on terodiline was 45 µg·l−1, 57 µg·l−1, and 45 µg·l−1, respectively, and a similar value was found in the healthy volunteers, 47 µg·l−1. The serum concentration of p-hydroxy-m-methoxyterodiline was 〈15 µg·l−1 both in the geriatric patients and in the healthy volunteers. Thus, terodiline 25 mg/day given to fragile elderly patients was well tolerated. It produced serum concentrations similar to those found after the standard dose of 37.5–50 mg given to younger, healthier patients.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 20 (1982), S. 390-392 
    ISSN: 1741-0444
    Schlagwort(e): Body temperature ; Electrocardiogram ; Heart Sounds ; Monitoring ; Oesophagus
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Electrocardiogram, body temperature and heart sounds are important variables to monitor during anaesthesia. An oesophageal probe for combined monitoring of these variables has been designed. Special consideration has been given to the potential hazards of placing devices close to the heart and in direct contact with the delicate oesophageal mucosa. The probe contains segmental silver electrodes for e.c.g. recording and a miniature accelerometer for heart sound detection, located close to the tip of a 5 mm O.D. PVC tubing.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...