Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1041
    Keywords: pethidine ; analgesics ; epidural-/intrathecal injection ; pharmacokinetics ; drug metabolism ; norpethidine ; adverse effects ; CSF drug levels
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The disposition of pethidine and its main metabolite, norpethidine, in cerebrospinal fluid (CSF) and plasma was studied in 11 thoracic surgery patients after lumbar epidural (100 mg;n=6) or lumbar intrathecal (25 mg;n=5) administration of pethidine. Pethidine appeared more slowly in plasma after intrathecal than after epidural administration (tmax 2.3 h and 14 min, respectively), but systemic bioavailability was similar. The CSF concentrations of pethidine were higher than those in plasma after both routes of administration. The maximal CSF/plasma concentration ratio was 6000 to 45000 after intrathecal administration but was only 26 to 97 after the epidural route. Pethidine was rapidly distributed in CSF; nine to ten h after the intrathecal and epidural injections the CSF/plasma concentration ratios were 12 to 89 and 2 to 33, respectively. The calculated bioavailability in CSF of epidural pethidine was 10.3%. The terminal elimination half-life of pethidine was 6.0 h (CSF) and 5.4 h (plasma) after intrathecal administration and 8.6 h (CSF) and 8.8 h (plasma) after epidural injection. The volume of distribution of unchanged pethidine in the subarachnoid space was 13 ml·kg−1 and clearance from the CSF was 15 µl·kg−1·min−1. In all patients receiving intrathecal pethidine and in some patients after epidural pethidine, CSF norpethidine concentrations were higher than those in plasma; the maximum CSF norpethidine was 102 to 1211 ng·ml−1 and 14 to 210 ng·ml−1 and the maximum CSF/plasma norpethidine concentration ratios were 21 to 652 and 0.6 to 14 times after intrathecal and epidural administration, respectively. Norpethidine was rapidly distributed and its level in CSF was about the same or lower than in plasma during the terminal elimination phase. The maximum CSF norpethidine level was 1.2±1.0% of that of pethidine after intrathecal injection. Thus, epidural pethidine enters the CSF more rapidly and to a greater extent than has been previously shown for epidural morphine, but pethidine is more rapidly redistributed from CSF. The terminal elimination half-life of pethidine was found to be long in relation to the reported duration of analgesia after a single spinal dose of pethidine, which suggests a potential risk of accumulation within the CSF on multiple spinal injections of pethidine. Pethidine is partly metabolised within the subarachnoid space by N-dealkylating enzymes in the CNS. After intrathecal injection of more than 25 mg pethidine, the concentration of the principle metabolite, norpethidine, in CSF may be higher than that associated with CNS toxicity in man.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 33 (1987), S. 499-504 
    ISSN: 1432-1041
    Keywords: morphine ; epidural administration ; pharmacokinetics ; CSF/plasma concentrations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary In order to determine the rate and degree of redistribution of morphine within the cerebrospinal fluid (CSF), and whether it was affected by the site of and volume of the injection, morphine was given to 23 elderly patients undergoing thoracotomy — in 10 ml saline in the lumbar epidural interspace (n=5), in 10 ml saline in the thoracic epidural interspace (n=5), in 2 ml saline in the thoracic interspace (n=8) and in 10 ml saline in the lumbar epidural interspace (n=5). The plasma concentration of morphine in all patients was comparable and was much lower than in the CSF. The CSF morphine concentration, measured as the area under the CSF concentration curve (AUC), the maximal CSF concentration (Cmax) and the time to reach maximal CSF concentration (tmax), varied between the four groups. The variation was related to the site of the injection; the AUC and Cmax were lower and tmax appeared later after thoracic than lumbar injection. Lumbar CSF morphine concentrations were further reduced by thoracic epidural injection of morphine in a small as compared to a large volume. The permeability of the dura to morphine was not influenced by the volume used. The results show that morphine is not homogenously distributed within the CSF. The availability of morphine to CSF from the epidural space is not altered by the injection volume, but the drug remains more localized in CSF after epidural injection of morphine in a small volume. The findings imply that epidural injection of morphine in a small volume at a site of nociceptive input should evoke spinal analgesia with least risk of supraspinally mediated side effects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...