Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 386 (1980), S. 193-197 
    ISSN: 1432-2013
    Keywords: Pressoreceptors ; Carotid arteries ; Barodenervation ; Carotid flow ; Peripheral resistance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A 12% blood pressure elevation was found during common carotid occlusion in the barodenervated, thoracotomised cat under Nembutal anaesthesia. This rise in blood pressure appeared to be the net result of an 18% increase of total peripheral resistance and a concomitant 5% decrease of mean aortic flow. When the occlusions were repeated after ganglionic blockade similar values were found, indicating that the increase in resistance had not resulted from reflex vasoconstriction. To test if this increase of total peripheral resistance was caused by a mechanical exclusion, Ohm's law for parallel resistances was applied to the systemic tree to calculate the rise in resistance due to obstruction of the carotid flow. The results thus obtained matched the observed increase of peripheral resistance. It is concluded that common carotid artery occlusion can be used to test completeness of barodenervation in the cat, if an increase in blood pressure of about 12% is allowed for.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-2622
    Keywords: Aqueous humor ; toxoplasma ; cytomegalovirus ; varicella zoster virus ; herpes simplex virus ; uveitis ; diagnostic test
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Analysis of local intraocular antibody production is a valuable tool with which to confirm a suspected clinical diagnosis in uveitis. We have analysed paired serum and aqueous samples for the presence of specific antibodies against toxoplasma, cytomegalovirus, herpes simplex virus and varicella zoster virus. Of the patients retrospectively diagnosed as having toxoplasma chorioretinitis 75% had a positive antibody coefficient indicating specific antibody production in the eye. Local antibody production in the eye directed against CMV confirmed the suspected diagnosis of CMV retinitis in 50% of the AIDS patients investigated. So far we have not been able to demonstrate local antibody production against herpes simplex virus (26 samples tested). Two of three patients with acute retinal necrosis had a positive antibody coefficient against varicella zoster virus. Both of these patients had an even higher titer in the aqueous than in serum. Since the choice of therapy, in infectious uveitis, depends on the causative organisms, it is very important to confirm a suspected clinical diagnosis by means of aqueous humor analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 12 (1984), S. 151-162 
    ISSN: 1573-9686
    Keywords: Matching ; Cardiac pump function ; Power ; Apparent source resistance ; Peripheral resistance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract We have studied the interrelation of left ventricle and arterial system in the anesthetized open-thorax cat. The ventricle was characterized by its pump function graph, relating mean ventricular pressure ( $$\bar P_{lv}$$ ) and mean aortic flow ( $$\bar F$$ ). The pump function graph was determined by means of an artificial periphery and on a beat-to-beat basis. The periphery was characterized by relating mean aortic pressure ( $$\bar P_{ao}$$ ) and mean flow. Mean aortic and mean left ventricular pressure could be related over a wide range of values by a proportionality factor $$\bar P_{ao} = a \cdot \bar P_{lv}$$ . In a series of five separate experiments a value of a=1.72±0.14 (mean±SD) was found. This simplified relation allows direct comparison of apparent source resistance (i.e., slope of pump function graph), (Rs), and peripheral resistance (Rp). It was also found experimentally that total external power ( $$\bar \dot w$$ ) could be calculated from mean aortic pressure and mean flow as well as from mean left ventricular pressure and mean flow (thus from the pump function graph) by $$\bar \dot w = c \cdot \bar P_{ao} \cdot \bar F = c \cdot a \cdot \bar P_{lv} \cdot \bar F$$ . The value of c=1.16±0.12 (mean±SD, n=4). Maximum external power was predicted for $$R_p /R_s = \bar P_{ao} /\bar P_{lv} = a$$ . In six different cats Rp/Rs ratio in the working point (i.e., mean left ventricular pressure and mean flow when the normal periphery loaded the heart) was found to be Rp/Rs=2.63±0.92. This value could not be shown to differ from that in the point where maximal external power was found, i.e., Rp/Rs=1.81±0.08 (n=6).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...