Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of sol gel science and technology 19 (2000), S. 371-375 
    ISSN: 1573-4846
    Keywords: phase separation ; silica ; capillary column ; HPLC ; CEC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Continuous macroporous silica gel networks were prepared in a fused silica capillary, and evaluated in reversed-phase liquid chromatography. Under pressure-driven conditions, considerable dependence of column efficiency on the linear velocity of the mobile phase was observed in spite of the small size of the silica skeletons. A major source of band broadening in the pressure-driven mode was found in the A-term of van Deemter equation. The performance of the continuous silica capillary column in the electro-driven mode was much better than that in the pressure-driven mode.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1436-2813
    Keywords: constrictive pericarditis ; left ventricular function
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Left ventricular function studies were performed on five patients with constrictive pericarditis. Functional data were obtained from intracardiac pressure measurements and cineangiocardiographic films. Left ventricular end-diastolic volume(LVEDV), left ventricular end-systolic volume (LVESV), ejection fraction (EF), stroke work index (SWI), circumferential fiber shortening, and percent circumferencial shortening were significantly below normal values in the five cases. These changes are reflected mainly in the degree of pericardial restriction. Reduction in mean Vcf was also observed. Theoretically, the velocity of ventricular internal circumferential shortening is also affected by changes in ventricular volume or resting myocardial fiber length, however, in patients with constrictive pericarditis, reduction in mean Vcf suggests left ventricular dysfunction. Our clinical studies indicate that evaluation of mean Vcf is valuable in the assessment of postoperative prognoses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Monolithic column ; silica monolith ; HPLC ; capillary liquid chromatography ; capillary electrochromatography ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Two types of monolithic silica columns derivatized to form an ODS phase, one prepared in a fused silica capillary (SR-FS) and the other prepared in a mold and clad with an engineering plastic (poly-ether-ether-ketone) (SR-PEEK), were evaluated. The column efficiency and pressure drop were compared with those of a column packed with 5-μm ODS-silica particles and of an ODS-silica monolith prepared in a mold and wrapped with PTFE tubing (SR-PTFE). SR-FS gave a lower pressure drop than a column packed with 5-μm particles by a factor of 20, and a plate height of 20 μm at a linear velocity below 1 mm/s. SR-PEEK showed higher flow-resistance than the other monolithic silica columns, but they still showed a minimum plate height of 8-10 μm and a lower pressure drop than popular commercial columns packed with 5-μm particles. The evaluation of SR-FS columns in a CEC mode showed much higher efficiency than in a pressure-driven mode.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 106-110 
    ISSN: 0935-6304
    Keywords: Silica ; monolithic column ; aging ; mesopores ; pore size distribution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Mesopore formation in silica gels having continuous macropores has been investigated. The macroporous wet silica gel prepared by the sol-gel process including phase separation was aged in a basic solvent making use of hydrolysis of urea in a closed condition. The mesopore structure was finally obtained by subsequent evaporation drying of solvent and heat-treatment at 600°C for 2 h. The dissolution-reprecipitation kinetics at the interfaces between wet gel skeletons and an external solvent affected the size and volume of pores formed within the skeletons. Below 120°C, mesopores suitable for various chromatographic applications have been formed typically within 24 h. On the other hand, at 200°C, the pore size attained the macropore dimensions (〉50 nm), and the whole macroporous morphology was significantly modified.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 477-479 
    ISSN: 0935-6304
    Keywords: Silica rod column ; micro-HPLC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...