Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Plasmas 8 (2001), S. 4534-4544 
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The three-dimensional, particle-in-cell code QUICKSILVER [J. P. Quintenz et al., Lasers Part. Beams 12, 283 (1994)] is now being used to simulate the inner region of the Z accelerator [R. B. Spielman et al., Phys. Plasmas 5, 2105 (1998)] at Sandia National Laboratories. The simulations model electron flow and anode losses in the double post-hole convolute, which couples four radial, magnetically insulated transmission lines (MITLs) in parallel to a single MITL that drives a Z-pinch load. To efficiently handle the large range in the magnetic field, 0〈B〈200 T, the particle pusher is modified to subcycle the electron advance relative to the field solver. Results from a series of simulations using a constant-impedance load are presented. The locations of electron losses to the anode in the convolute are in qualitative agreement with damage to the Z hardware. The electron energy deposited in these anode regions rapidly heats the surface to temperatures above 400 °C—the threshold at which anode plasma formation is expected. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 1834-1836 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Target diagnostics on PBFA II will include a time-resolved x-ray diode array, an energy-resolved, time-integrated x-ray camera, and a grazing incidence spectrometer. A clean vacuum, independent of that on PBFA II, will be supplied to the detectors to maintain more reproducible calibrations. We also describe the diagnostics and outline the calculations which determined the shielding required. Based on the calculations the background due to bremsstrahlung in the least sensitive diagnostic is 12 eV/pixel. The appropriate shielding is being built to field these diagnostics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...