Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 1756-1760 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We discuss practical aspects of Kelvin probe force microscopy (KFM) which are important to obtain stable images of the electric surface potential distribution at high spatial resolution (〈100 nm) and high potential sensitivity (〈1 mV) on conducting and nonconducting samples. We compare metal-coated and semiconducting tips with respect to their suitability for KFM. Components of the metal coating can become detached during scanning, introducing sudden offset jumps in the potential maps (typically up to 350 mV between adjacent scan lines). However, n-doped silicon tips show no substantial tip alterations and, therefore, provide a stable reference during the experiment (offset jumps typically up to 40 mV between adjacent scan lines). These semiconducting tips must be electrically connected via contact pads. We use InGa and colloidal silver pads which are easily applied to the substrate supporting the cantilever and have a low enough differential contact resistance (350 Ω and 2.2 kΩ, respectively). Furthermore, we introduce a simple procedure to fine tune the feedback which detects the electric surface potential and show how the basic KFM setup has to be modified to gain access to the necessary control signals. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 84 (1998), S. 1168-1173 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The combination of atomic force microscopy and Kelvin probe technology is a powerful tool to obtain high-resolution maps of the surface potential distribution on conducting and nonconducting samples. However, resolution and contrast transfer of this method have not been fully understood, so far. To obtain a better quantitative understanding, we introduce a model which correlates the measured potential with the actual surface potential distribution, and we compare numerical simulations of the three-dimensional tip–specimen model with experimental data from test structures. The observed potential is a locally weighted average over all potentials present on the sample surface. The model allows us to calculate these weighting factors and, furthermore, leads to the conclusion that good resolution in potential maps is obtained by long and slender but slightly blunt tips on cantilevers of minimal width and surface area. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...