Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 63 (1991), S. 2383-2386 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 61 (1989), S. 2024-2030 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 55 (1983), S. 1800-1804 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 3 (1989), S. 443-449 
    ISSN: 0886-9383
    Keywords: Multicomponent analysis ; Iterative refinement ; Simplex method ; Condition numbers ; Linear programming ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Concentration estimates of components present in a sample mixture can be obtained using matrix mathematics. In the past, the condition number of the calibration matrix has been used to give an amplification factor by which uncertainties in data can work through to errors in the concentration estimates. This paper explores an additional interpretation of condition numbers with regards to significant figures and rounding errors. A procedure is suggested which will always give the most accurate concentration estimates provided the calibration matrix is not too ill-conditioned. Condition numbers have also been used by analytical chemists to discuss the error bounds for concentration estimates. Unfortunately, only one representative error bound can be approximated for all the components. This paper will show how to compute bounds for individual concentration estimates obtained as solutions to a system of m equations and n unknowns. The procedure is appropriate when calibration data and sample responses are inaccurate.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 153-163 
    ISSN: 0886-9383
    Keywords: Generalized inverse ; K-matrix analysis ; P-matrix analysis ; Least squares ; Principal component regression ; Partial least squares ; Continuum regression ; Beer's law ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper consists of two distinct but related parts. In the first part a geometric theory of generalized inverses is presented and a methodology based on this theory is developed and applied to solve the K-matrix and P-matrix forms of Beer's law. It is shown that most currently accepted and practiced methods for solving these forms of Beer's law are just special cases of this geometric theory of generalized inverses. In addition, this geometric theory is used to explain why the current methods work and why they fail.In the second part a general methodology that includes as special cases least squares, principal component regression, partial least squares 1 and 2, continuum regression plus a variety of other described and undescribed methodologies is presented and then applied to solve the P-matrix formulation of Beer's law. This general methodology, like the first, is also geometric in nature and relies on an understanding of projections.The main emphasis of this paper is one of perspective, which, if understood, provides the proper foundation for answering the general but extremely hard and possibly unanswerable question “what is the best method?”.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 6 (1992), S. 85-96 
    ISSN: 0886-9383
    Keywords: Optimization ; Calibration ; Simulated annealing ; Experimental design ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper utilizes variable step size generalized simulated annealing (VSGSA) to design multicomponent calibration samples for spectroscopic data. VSGSA is an optimization procedure which is capable of converging to exact positions of global optima located on multidimensional continuous functions. On the basis of analysis sample response vectors, optimally designed calibration concentration matrices are obtained assuming knowledge of components present. The complexity of response surfaces established by the optimization criteria is described.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 37-48 
    ISSN: 0886-9383
    Keywords: Optimization ; Simulated annealing ; Calibration ; Experimental design ; Multicomponent analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Generalized simulated annealing (GSA) is an optimization procedure for locating the global optimum (maximum or minimum) of multidimenisonal continuous functions. GSA has been modified for optimization of discrete functions. Selection of calibration samples from an existing set defines discrete optimization and GSA is used to select optimal sets of calibration samples for specific analysis samples. The procedure is applied to near-infrared spectra. When compared to using the complete set of 37 calibration samples, concentration prediction errors were reduced 50%-100% by using select sets of two to seven calibration samples. Additionally, GSA was able to improve a poorly designed experiment. GSA devised augmented experimental designs such that the overall experimental design (original plus augmented) was more orthogonal than the original.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 6 (1992), S. 217-225 
    ISSN: 0886-9383
    Keywords: Principal component regression ; Calibration ; Optimality ; Principal component selection ; Quantitative structure-activity relationship ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Principal components (PCs) for principal component regression (PCR) have historically been selected from the top down for a reliable predictive model. That is, the PCs are arranged in a list starting with the most informative (PC associated with the largest singular value) and proceeding to the least informative (PC associated with the smallest singular value). PCs are then chosen starting at the top of this list. This paper discusses an alternative procedure of treating PC selection as an optimization problem. Specifically, without any regard to the ordering, the optimal subset of PCs for an acceptable predictive model is desired. Five data sets are analyzed using the conventional and alternative approaches. Two data sets are spectroscopic in nature, two data sets deal with quantitative structure-activity relationships (QSARs) and one data set is concerned with modeling. All five data sets confirm that selection of a subset without consideration to order secures the best results with PCR. One data set is also compared using partial least squares 1.
    Additional Material: 7 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 3 (1989), S. 409-418 
    ISSN: 0886-9383
    Keywords: Multivariate calibration ; Singular value decomposition ; Regression diagnostics ; Collinearity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Care is required for multicomponent analysis if misleading results are to be avoided. The problem of ill-conditioned calibration matrices is of primary concern. This type of numerical instability is represented as spectral overlap of calibration spectra. Depending on the degree of spectral overlap, the sample concentration estimates can be severely affected. A practical statistical procedure is discussed which tests for the presence of spectral overlap among the pure-component spectra and simultaneously assesses the degree that concentration estimates may be degraded. Guidelines are developed to ascertain how much departure from spectral orthogonality is acceptable.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. 283-308 
    ISSN: 0886-9383
    Keywords: simulated annealing ; threshold acceptance ; wavelength selection ; selectivity ; optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Simulated annealing (SA) is a stochastic search method that has been applied to combinatorial search problems in chemometrics. Unlike strict iterative improvement methods, SA tolerates temporary moves to detrimental parameter configurations during an optimization. The method used by SA to decide whether or not to accept detrimental steps is a special case of a more general acceptance rule. The present work investigates the performance of various SA-type algorithms that differ only in the acceptance rule for detrimental steps when optimizing continuous or discrete problems. A method for step width modulation is introduced to overcome the poor ability of SA type algorithms to locate the exact extreme of a function. The studied search strategies are modified for the discrete problem of wavelength selection. In order to evaluate SA-type algorithms and their abilities to deal with the wavelength selection problem, two global measures of selectivity are used as criteria to determine the most suitable wavelength subset that maximizes selectivity for pure component ultraviolet-visible spectra.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...