Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Industrial & engineering chemistry 43 (1951), S. 961-968 
    ISSN: 1520-5045
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Industrial & engineering chemistry 46 (1954), S. 1583-1589 
    ISSN: 1520-5045
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Industrial & engineering chemistry 42 (1950), S. 1048-1057 
    ISSN: 1520-5045
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 5 (1959), S. 446-452 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: An open type of reciprocating-plate extraction column was developed, and it is proposed that the scaling up of such a column should be straightforward; that is, the height of an equivalent theoretical stage (H.E.T.S.) and the throughput per unit area should be independent of the diameter of the column.Plates having 5/8-in.-diameter holes and 62.8% free space were selected to minimize the resistance to countercurrent flow in the column. With this design low H.E.T.S. values were achieved at throughputs much higher than those reported for other columns. Thus for two systems the present column was shown to require the lowest volume of column to accomplish a given extraction job. Data were obtained in a 3-in.-diameter column on two systems, methyl isobutyl ketone-acetic acid-water and o-xylene-acetic acid-water. Throughputs studied on the first system ranged from 547 to 1,837 gal./hr./sq. ft., and the corresponding minimum H.E.T.S. values achieved were 4.3 and 7.5 in. respectively. For the second system minimum H.E.T.S. values of 7.7 and 9.1 in. were attained at throughputs of 424 and 804 gal./hr./sq. ft. respectively.Extraction column design procedures are discussed. The fabrication of the reciprocating-plate column is relatively simple, and this should encourage its use first in pilot-scale sizes and ultimately in large-scale columns.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 37 (1991), S. 360-366 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Field experience with several industrial reciprocating plate liquid-liquid extraction columns indicated that large density gradients in the continuous phase resulted in excessive backmixing. Since there are no published data on the effect of higher density in the upper section compared to lower density in the bottom section of the column, experiments were performed with the calcium chloride brine-water system in a 76.2 mm diameter reciprocating plate column.Axial dispersion coefficients, E, were found to be 10-20 times higher than the values in systems with uniform densities. E decreased with increasing agitation to 30% of the value with no agitation. The effect of increasing flow rate of water up the column was to increase both E and the Peclet number. E was correlated with the density difference between any point in the column and tap water. Another correlation was obtained showing the effects of buoyant and mechanical energy input on axial dispersion.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...