Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0509
    Keywords: Key words: CT arterial portography〈+〉—〈+〉Gadolinium〈+〉—〈+〉Liver, MR, 761.1213〈+〉—〈+〉Magnetic resonance (MR), rapid imaging.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Background: The purpose of this study was to evaluate patients with wedge-shaped perfusion defects seen on spiral CT arterial portography for the presence of transient increased wedge-shaped enhancement on dynamic gadolinium-enhanced gradient echo MR images. Methods: Nineteen patients underwent CTAP and MRI within a 2-week interval. All patients with wedge-shaped perfusion defects on CT arterial portography were evaluated in a separate review session for the presence of transient increased segmental hepatic enhancement on dynamic gadolinium-enhanced spoiled gradient echo (SGE) MR images. Results: Eight patients were identified to have subsegmental, segmental, or lobar wedge-shaped perfusion defects by CT arterial portography. In 8/8 patients, there was transient wedge-shaped increased hepatic enhancement on MR images which corresponded to the perfusion defects identified on CT arterial portography. Transient increased enhancement on MR images was observed on immediate postgadolinium images as high-signal intensity of the involved subsegment, segment, or lobe. This relatively high-signal area faded to near isointensity in all cases on images obtained at 45 s. Conclusion: Wedge-shaped perfusion defects demonstrated by CT arterial portography corresponded to wedge-shaped increased hepatic enhancement following gadolinium administration on SGE MR images.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0509
    Keywords: Key words: Kidney, abscess〈+〉—〈+〉Kidney, infection〈+〉—〈+〉Kidney, magnetic resonance imaging〈+〉—〈+〉Kidney, computed tomography.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Purpose: To determine the appearance of renal abscesses on gadolinium-enhanced magnetic resonance (MR) images, we reviewed 12 MR studies of eight patients with renal abscesses. These findings were compared with findings on other imaging modalities. Methods: Eight patients underwent 12 MR studies at 1.5 T, including T1-weighted gradient echo and fat-suppressed spin echo pre- and post-Gd-DTPA enhancement. Two radiologists retrospectively reviewed the MR images and compared MR findings to the findings on contrast-enhanced computed tomography (CECT) in five patients, noncontrast computed tomography (NCCT) in two patients, and ultrasound in all patients. Results: On contrast-enhanced MR images, renal abscesses were clearly depicted as heterogeneously low-signal-intensity lesions. Four patients had solitary abscesses, and four had multiple abscesses. Prominent perinephric inflammatory stranding was observed in six patients and was best shown on gadolinium-enhanced T1 fat-suppressed images. CECT findings were comparable to contrast-enhanced MR images, although contrast resolution was less on CECT images in all cases. Renal abscesses were poorly shown on NCCT and ultrasound images. Conclusion: Renal abscesses are clearly shown on gadolinium-enhanced MR images as low-signal-intensity lesions associated with prominent perinephric inflammatory strands. In this study, NCCT and ultrasound studies are poor at defining abscesses. Despite lesser contrast resolution of CECT versus MRI, the findings in cases of renal abscesses are similar. In patients with elevated serum creatinine, iodine contrast allergy, or the need for serial exams, MRI may be the best imaging technique to evaluate renal abscesses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1084
    Keywords: Pancreas ; MR ; Contrast enhancement ; Gadolinium ; Manganese
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The purpose of this paper was to compare manganese-DPDP (Mn-DPDP) and gadolinium chelate (Gd-DTPA) contrast agents for enhancement of the normal pancreas. A total of 14 patients with focal liver disease underwent Mn-DPDP and Gd-DTPA-enhanced 1.5T MR examinations using spoiled gradient-echo (FLASH) technique at tw separate times. Contrast agents were injected according to the currently recommended practices: GD-DTPA was injected as a rapid bolus injection in a dosage of 0.1 mmol/kg, and Mn-DPDP was injected as a slow IV injection in a dosage of 5 μmol/kg. Quantitative region of interest measurements were made in 11 patients, and percent contrast enhancement of the pancreas and pancreas-fat signal-to noise ratios (SNR) were determined for each agent. Images were also evaluated qualitatively by consensus reading of two investigators and overall scan quality was rated on a scale from 1 (poor) to 4 (very good). Enhancement of the pancreas immediately post Gd-DTPA was significantly higher than 15 min post Mn-DPDP (73.3 vs 36.3%;p = 0.003). On postcontrast images the pancreas-fat SNR measurements were 7.7 (i.e., pancreas higher in signal than fat) and 6.1 for Gd-DTPA and Mn-DPDP, respectively, which was significantly different (p 〈 0.001). Imagine quality was rated as 3.1 and 2.5 for Gd-DTPA- and Mn-DPDP-enhanced images respectively. The normal pancreas enhances significantly more with Gd-DTPA than with Mn-DPDP administered under the conditions of this study. Overall image quality is also greater on the Gd-DTPA-enhanced images.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...