Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Antonie van Leeuwenhoek 49 (1983), S. 613-614 
    ISSN: 1572-9699
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European journal of clinical microbiology & infectious diseases 8 (1989), S. 968-973 
    ISSN: 1435-4373
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Methicillin resistance inStaphylococcus aureus can be difficult to recognize because it may be expressed in only a small portion of the population. The optimal reference to use in comparing different test systems is controversial. In this study MIC values of ≤ 4 mg/l as observed in two experiments, each including 12 test systems (24 h incubation), were used to define strains as methicillin-susceptible. This strict standard was used to compare 24 quantitative and 36 agar diffusion test systems applied to 61 strains. These test systems included six agar media (Mueller Hinton, Oxoid and BBL; and Iso-Sensitest, Oxoid; all with and without 5% NaCl), three broth media of the same type, two incubation temperatures (30 °C and 37 °C), two incubation times (24 h and 48 h) and five disc types [methicillin 10µg (M 10), three types of methicillin 5µg (M 5) and oxacillin 1µg (O 1)]. Standardized high inocula were used. It was concluded that 24 h incubation is preferable to 48 h; at 24 h, differences in recognition of methicillin-resistantStaphylococcus aureus (MRSA) among 12 quantitative test systems were not statistically significant; incubation at 30 °C gave slighty better results in difussion tests. Reproducibility of quantitative data (Friedman test) was better on Mueller Hinton media (p〈0.001) than on Iso-Sensitest medium in both dilution and agar diffusion test systems. The rank order of discs was M 5〉M 10〉O 1 (p〈0.001). An inhibition zone of 〈13 mm with a M 5µg (BBL) disc should be interpreted as MRSA.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...