Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1619-7089
    Keywords: Soft tissue sarcomas ; Thallium-201 ; Magnetic resonance imaging ; Post-therapy changes ; Residual/recurrent tumors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We performed a prospective study to evaluate the imaging potential of thallium-201 as compared with other imaging modalities in differentiating residual/re-current tumors from post-therapy changes in patients with musculoskeletal sarcomas.201TI scans, magnetic resonance imaging (17), X-ray computed tomography (6) or contrast angiography (6) studies in 29 patients previously treated for musculoskeletal sarcomas were correlated with either histopathologic findings (26 patients) or 2-year clinical follow-up (three patients). All imaging studies were acquired within 2 weeks. Ratios of201T1 tumor uptake to the contralateral (28 patients) or adjacent region of interest were calculated. When qualitative interpretation was in doubt, only those cases with a ratio of 1.5 or more were considered suggestive of recurrent or residual viable tumor tissue. Residual or recurrent tumor tissue was verified in 21 patients by biopsy. All had true-positive201Tl scans while the other imaging modalities were true-positive in 20 and equivocal in one. In eight patients, there was no evidence of viable tumor tissue as proven by biopsy in five and long-term clinical follow-up in three.201Tl scan was false-positive (ratio 1.5) in one patient and true-negative in seven while the other' imaging modalities had four false-positives. The average201T1 ratios were 3.8±1.1 in the true-positive cases and 1.3±0.3 in the true-negative cases. The percentage sensitivities, specificities, and accuracy for201T1 were 100%, 87.5%, and 96.5% versus 95%, 50%, and 82.7% respectively for other imaging modalities These results indicate that201T1 scintigraphy is more accurate than other imaging modalities in differentiating residual/recurrent musculoskeletal sarcomas from post-therapy changes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Monoclonal antibody ; 3F8 ; Ganglioside ; Small-cell lung cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The present study evaluated the ability of the anti-GD2 ganglioside monoclonal antibody 3F8 to target tumor sites in patients with small-cell lung cancer (SCLC). Of 12 patients entered into the trial, ten received intravenous 3F8 labeled with 2 or 10 mCi iodine-131. The first five patients had recurrent or progressive disease after chemotherapy. Subsequent patients were studied before starting chemotherapy. Radionuclide scans were performed on days 1, 2, and 3 post-infusion and once between day 5 and day 7. Four patients underwent single-photon emission tomography (SPET) imaging. Radionuclide scans demonstrated localization to all known sites of disease, other than small brain metastases in one patient. SPET/CT scan fusion images confirmed precise localization. No significant toxicity was observed. Mean serum half-life was 64.2 h. Analysis of specimens from one patient who died of unrelated causes 6 days post-infusion confirmed the scan results. The present study demonstrates that 3F8 targets SCLC sites in patients. Further studies of anti-GD2 antibodies with higher doses of antibody and radionuclide are warranted to evaluate their role in SCLC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 27 (2000), S. 1564-1578 
    ISSN: 1619-7089
    Keywords: Fluorine-18 fluorodeoxyglucose Positron emission tomography Lymphoma Hodgkin's disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Positron emission tomography (PET) imaging has become a very useful technique for staging and monitoring therapy response in lymphoma, providing unique information about the biological behavior of disease. Increased fluorine-18 fluorodeoxyglucose (FDG) uptake in lymphoma is based on elevated glycolysis and longer residence time of FDG in malignant cells compared with most normal tissues. The metabolic information provided by this technique suggests that FDG-PET may be more sensitive than the anatomical imaging modalities. Computed tomography (CT) is the principal imaging modality for the staging and restaging of lymphoma. Nonetheless, this technique has significant shortcomings, particularly in the post-therapy setting. Gallium-67 scintigraphy has played an important role in monitoring response to therapy and follow-up of patients; however, the sensitivity of 67Ga depends on the subtype of lymphoma and the size and location of disease. Published results strongly indicate that FDG-PET is superior to 67Ga imaging and may be equal or superior to CT for the detection of nodal as well as extranodal involvement in lymphoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1619-7089
    Keywords: Dual-isotope single-photon emission tomography ; Intracardiac masses ; Cardiac lymphoma ; Technetium-99m sestamibi
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A patient with diffuse large cell lymphoma involving the interventricular septum and the inferior ventricular wall was imaged with a simultaneous dual-isotope single-photon emission tomography (SPET) acquisition technique, using the radiotracers technetium-99m hexakis 2-methoxyisobutylisonitrile (sestamibi) and gallium-67 citrate, in conjunction with echocardiography, prior to and following the first course of chemotherapy. Simultaneous acquisition — with the advantage of displaying corresponding sets of SPET slices without any need for position correction - , supplemented by echocardiography, increased the accuracy of evaluation of the extent of disease and response to treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1619-7089
    Keywords: Medullary thyroid carcinoma ; Tumour imaging ; Technetium-99m (pentavalent)-DMSA ; Technetium-99m sestamibi ; Thallium-201
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Radionuclide scanning with tumour-seeking agents such as pentavalent technetium-99m dimercaptosuccinic acid [99mTc(V)-DMSA], thallium-201 and technetium-99m sestamibi (MIBI) has been reported to be useful in the detection of medullary thyroid carcinoma (MTC). We undertook a study in 14 MTC patients to determine the comparative imaging potential of201Tl, MIBI and99mTc(V)-DMSA in the detection of recurrent or metastatic MTC. All patients underwent total thyroidectomy and had persistently elevated serum calcitonin levels after the surgery. Scintigraphic studies were carried out 20 min after the injection of 111 MBq of201Tl or 555 MBq of MIBI and 2 h following the injection of 370 MBq of99mTc(V)-DMSA. All scintigraphic findings were correlated with contemporaneous CT or MRI studies. CT, MRI and bone scans showed 42 (26 bone, 16 soft tissue) metastatic sites in 11 of the 14 patients. In the remaining three patients no lesions were detected during diagnostic evaluation.99mTc(V)-DMSA showed all of the soft tissue metastases but could not show two bone lesions. On the other hand, MIBI imaging was false-negative in 22 (52%) sites and201Tl was false-negative in 34 (80%) sites. Overall, lesion detection sensitivities for99mTc(V)-DMSA, MIBI and201Tl were 95%, 47% and 19% respectively. We conclude that99mTc(V)-DMSA is clearly superior to MIBI and201Tl in the follow-up of MTC patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1619-7089
    Keywords: Key words: Nasopharyngeal carcinoma ; Technetium tetrofosmin ; Technetium-99m sestamibi ; Residual/recurrent disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1619-7089
    Keywords: Nasopharyngeal carcinoma ; Technetium tetrofosmin ; Technetium-99m sestamibi ; Residual/recurrent disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer,99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent diseuse. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were rot statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...