Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiac surgery 13 (1998), S. 0 
    ISSN: 1540-8191
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract Background: The Medtronic Freestyle aortic root bioprosthesis is a complete porcine aortic root to allow implantation (1) as a subcoronary valve replacement by removing graft sinus aorta, (2) as a cylinder with the sinotubular junction intact within the aorta (root inclusion), or (3) as a complete aortic root replacement. The choice among the three implant techniques depends on surgeon preference or upon the pathology encountered. The advantages and differences among the three implant techniques are examined. Methods: The Medtronic Freestyle bioprosthesis was implanted in 1163 patients in a Food and Drug administration (FDA) clinical trial between August 1992 and October 1997. There were 21 centers in the international trial using a single data repository. Clinical data was collected prior to and at operation, at 3 to 6 months and annually. The data were compiled and statistical analysis performed at the data center. Results: Patients having subcoronary valve implants were older (80% 〉 65 years) and aortic occlusion time was about 20 minutes less than the other methods. Patients having aortic root replacement presented with more aortic valve insufficiency (20%). Pathology of the aortic root and ascending aorta requiring repair was 26%, and larger (27 mm) valves were used in 40% of patients. Risk of operation was lowest (5.0%) with subcoronary valve implants and highest (11.7%) with root replacement technique. Thromboembolism was higher, early and late, with root inclusion (3.0,3.9%/patient per year) and root replacement (3.2, 3.0%/patient per year) than for subcoronary implants (1.8, 1.6%/patient per year). There were more patients taking warfarin at the 4-year point with root inclusion (20%) or root replacement techniques (24%) than among patients having subcoronary implants (14%). Explants of the valve occurred in 2% of patients, none of whom had aortic root replacement. Conclusions: The Medtronic Freestyle bioprosthesis is an effective and versatile device for replacement of the aortic valve. It offers implant techniques that can treat the aortic root pathology encountered at surgery and allows the operation to proceed according to surgeon preference.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 22 (1889), S. 3305-3310 
    ISSN: 0365-9496
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...