Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1432-1750
    Schlagwort(e): Key words: IgE—Il-4 knockout—Latex allergy—Lung compliance—Pulmonary resistance.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. Sensitization to latex proteins can cause immediate IgE mast cell-mediated reactions. Health care workers have been found to be particularly at risk because of high exposure. Latex allergy can be produced in mice as demonstrated by IgE and eosinophil responses. Thus the mouse is a potential animal model for studying this disease, but the airway response to latex sensitization in mice has not been evaluated previously. In the present study, we immunized BALB/c mice intranasally with nonammoniated latex proteins. Animals were anesthetized, and lung mechanics were evaluated plethysmographically. Changes in pulmonary conductance (GL) and compliance (Cdyn) were measured in response to a nonspecific challenge with methacholine or to a direct challenge with intravenous latex antigen. Latex sensitization resulted in elevated levels of IgE and latex-specific IgG1 as well as interstitial infiltrates consistent with an allergic response. The methacholine dose-response ED50 for GL was 116.4 μg for the control mice and fell significantly to 20.9 μg for latex-sensitized mice. The ED50 calculated for Cdyn was also significantly lower after latex sensitization. The GL in latex-sensitized mice challenged with latex antigen fell significantly from a prechallenge value of 1.87 ± 0.41 (S.E.) to 0.198 ± 0.03 ml · s−1· cmH2O after latex antigen challenge. The results indicate that latex-sensitized mice did exhibit increased airway reactivity in the methacholine challenge test. The latex allergic response in mice is unique in that direct challenge with latex antigen itself also resulted in a significant airway response.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Annals of biomedical engineering 26 (1998), S. 914-930 
    ISSN: 1573-9686
    Schlagwort(e): Flow distribution ; Axial diffusion ; Mathematical model ; Perfusion heterogeneity ; Relative dispersion ; Heterogeneity ; Capillary transit times ; Indicator dilution
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin , Technik allgemein
    Notizen: Abstract To mathematically model multiple indicator dilution (MID) data for the purpose of estimating parameters descriptive of indicator-tissue interactions, it is necessary to account for the effects of the distribution of capillary transit times, hc(t) In this paper, we present an efficient approach for incorporating hc(t) in the mathematical modeling of MID data. In this method, the solution of the model partial differential equations obtained at different locations along the model capillary having the longest transit time provides the outflow concentrations for all capillaries. When weighted by hc(t) these capillary outflow concentrations provide the outflow concentration versus time curve for the capillary bed. The method is appropriate whether the available data on capillary dispersion are in terms of capillary transit time or relative flow distributions, and whether the dispersion results from convection time differences among heterogeneous parallel pathways or axial diffusion along individual pathways. Finally, we show that the knowledge of a relationship among the moments of hc(t) rather than hc(t) per se, is sufficient information to account for the effect of hc(t) in the mathematical modeling interpretation of MID data. This relationship can be determined by including a flow-limited indicator in the injected bolus, thus providing an efficient means for obtaining the experimental data sufficient to account for capillary flow and transit time heterogeneity in MID modeling. © 1998 Biomedical Engineering Society. PAC98: 8745Ft, 8710+e, 0230Jr
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...