    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: VOLLMANN, D., et al.: Subthreshold Test Pulses Versus Low Energy Shock Delivery to Estimate High Energy Lead Impedance in Implanted Cardioverter Defibrillator Patients. The high energy lead impedance is valuable for detecting lead failure in ICDs, but until recently shock delivery was necessary for high energy impedance measurement. This study compared the use of subthreshold test pulses and low energy test shocks to estimate the high energy impedance. Immediately after implantation of Ventak Prizm ICDs in 29 patients, the lead impedance was measured with five subthreshold (0.4 μJ) test pulses, 5 low energy (1.1 J) shocks, and two to three high energy (16 ± 4.5 J) shocks. The mean impedances measured using high energy shocks, low energy shocks, and subthreshold pulses were 42.0 ± 7.3 Ω, 46.5 ± 8.1 Ω , and 42.4 ± 7.1 Ω , respectively. The impedances measured using high and low energy shocks differed significantly (P 〈0.0001) , while those obtained by high energy shocks and low energy pulses did not (P = 0.63) . According to the Pearson correlation coefficient, the impedance measurements with subthreshold pulses and low energy shocks were both closely correlated(P 〈 0.0001)with impedance values determined with high energy shocks. However, while the impedance values tended to be higher when measured with low energy shocks, the concordance correlation coefficient (c) was higher for subthreshold test pulse versus high energy shock(c = 0.92)than for low versus high energy shock(c = 0.73). Furthermore, the intraindividual variability of impedance measurements was lower with subthreshold pulse measurements than with low energy shocks. Compared with low energy shocks, impedance measurement with subthreshold pulses has higher reproducibility and a higher correlation with the impedance obtained by high energy shock delivery. Safe and painless high energy impedance estimation with subthreshold pulses might, therefore, help to detect ICD lead failure during routine follow-up. (PACE 2003; 26:[Pt. II]:457–460)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 27 (2004), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Desminopathy is a neuromuscular disorder associated with the accumulation of the protein desmin. This article reports a case of a man with a mutation in the desmin gene suffering from cardiomyopathy and skeletal myopathy. This patient underwent implantable cardioverter defibrillator (ICD) implantation for prognostic considerations and subsequently developed a sustained ventricular tachycardia (SVT). While nonsustained VTs (NSVT) have previously been reported, this is the first time that a SVT could be seen in a patient with this disease. (PACE 2004; 27:559–560)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 25 (2002), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: VOLLMANN, D., et al.: Inhibition of Bradycardia Pacing and Detection of Ventricular Fibrillation Due to Far-Field Atrial Sensing in a Triple Chamber Implantable Cardioverter Defibrillator. Oversensing of intracardiac signals or myopotentials may cause inappropriate ICD therapy. Reports on far-field sensing of atrial signals are rare, and inappropriate ICD therapy due to oversensing of atrial fibrillation has not yet been described. This report presents a patient with a triple chamber ICD and a history of His-bundle ablation who experienced asystolic ventricular pauses and inappropriate detection of ventricular fibrillation due to far-field oversensing of atrial fibrillation. Several factors contributed to the complication, which resolved after reduction of the ventricular sensitivity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...