Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 53 (1969), S. 13-30 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents In this paper a theory is presented, dealing with transient operational behavior of AC—squirrelcage-motors. Using a method developed byKovacs andStepina the voltages and currents are represented by “Raumzeiger”. This theory is based on the squirrel cage havingZ2-rotor circuits. The time-dependence of the voltages and currents is arbitrary. As a result of this not only the basic magnetic arrow but also the arrow due to the triple numbers of pairs of poles is taken into consideration in the calculation.
    Notes: Übersicht In der vorliegenden Arbeit wird die Theorie des transienten Betriebsverhaltens von Drehstromkäfigankermotoren behandelt. Die Spannungen und Ströme wurden nachKovacs-Stepina mit Hilfe von Raumzeigern dargestellt. Die Theorie geht vom Käfiganker mit neuenZ2-Läufermaschinen aus und läßt einen beliebigen zeitlichen Verlauf der Spannungen und Ströme zu. Aus diesem Grunde werden neben den magnetischen Grundfehlern auch die Felder dreifacher Polpaarzahl in den Rechnungsgang einbezogen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 51 (1966), S. 38-51 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents The influence of the exitor-winding and the stators resistant during the asynchronous starting of synchronous machines with salient poles are probed by using the equations that are published in authors earlier work [1]. Simple equations for current and torque are derived by neglecting the sator resistant. The amplitude of the swinging torque is probed exatcly. The publication is concluded by showing how one could approximately estimate the maximum of the amplitude of the swinging torque.
    Notes: Übersicht Mit Hilfe der in einer früheren Arbeit der Verfasser [1] gefundenen Gleichungen werden der Einfluß der Erregerwicklung und des Ständerwiderstandes auf den asynchronen Anlauf untersucht. Unter Vernachlässigung des Ständerwiderstandes werden relativ einfache Gleichungen für die Ströme und Drehmomente hergeleitet. Die Pendelmomentamplitude und die sie bestimmenden Größen werden einer eingehenden Betrachtung unterzogen. Abschließend wird beschrieben, auf welche Weise man bei großen Synchronmotoren die höchste Pendelmomentamplitude abzuschätzen vermag.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 51 (1967), S. 212-212 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 67 (1984), S. 195-201 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents A shuttleless loom being in stand-still is coupled to the idling asynchronous motor. This transient may be calculated by means of a simulation model. A comparison with fest results points out there is a good correspondence between measurement and calculation. The forced oscillation appearing after starting of the loom may be damped considerably by the aid of an optimal motor design. It is proved that this optimal motor is not only suitable for the steady-state behaviour but also for the transient one.
    Notes: Übersicht Der Hochlauf einer Webmaschine, die im Still-stand an den leerlaufenden Asynchronmotor angekuppelt wird, kann mit Hilfe eines Simulationsmodells vorausberechnet werden. Der Vergleich mit Messungen zeigt eine gute Übereinstimmung. Ein optimierter Motor vermag die sich nach dem Hochlauf einstellende stationäre Drehschwingung erheblich zu dämpfen. Es wird nachgewiesen, daß dieser optimierte Motor auch für den Hochlauf sehr gut geeignet ist.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 67 (1984), S. 119-126 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents The driving system asynchronous motor/loom is submitted to forced oscillations. Hence, it is necessary for the motor to be electrically oversized. You have also to take into account a high material stress of the mechanical parts. For an efficient system design it is important to calculate this forced oscillation. In this case a simulation model has been used described all measured variables of the real system quite exactly. An optimization run points out an optimal motor should neither have a “smooth” steady state characteristic nor have a high moment of inertia to damp oscillations — contrary to the traditional opinion.
    Notes: Übersicht Der mechanische Verband Asynchronmaschine/Webmaschine führt eine stationäre Drehschwingung aus. Daher ist man gezwungen, den Motor elektrisch überzudimensionieren und eine hohe Materialbeanspruchung der mechanischen Teile in Kauf zu nehmen. Die für eine sinnvolle Auslegung des Verbandes notwendige Vorausberechnung der Dauerschwingung erfolgt auf der Grundlage eines Simulationsmodells. Das Modell vermag alle meßtechnisch erfaßten Variablen hinreichend genau nachzubilden. Anhand einer Optimierungsrechnung für den Motor wird nachgewiesen, daß er — entgegen herkömmlicher Annahmen — weder eine “weiche” Drehmoment-Drehzahl-Kennlinie noch ein besonders hohes Trägheitsmoment aufweisen muß, um auftretende Pendelungen zu dämpfen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 50 (1966), S. 372-387 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Summary The synchronous machine with salient poles is treated during the asynchronous starting as a induction motor with unsymmetrical rotor. There airgap-fields are determined by the magnetic conductivity of the airgap and the current per cm of rotor and stator. The magnetic flux of each circuit is found by the integration of the airgap-fields. The Diagrammvectors of current are obtained by the differential-equations of voltage. The amplitude of the torque, which is swinging with double slip frequency, and the asynchronous corque are calculated by the product of induction and current per cm. The testet values of a 3000 KW synthronous machine show a good agreement with calculated ones.
    Notes: Übersicht Für den asynchronen Anlauf wird die Schenkelpolsynchronmaschine als Asynchronmaschine mit Läuferunsymmetrien behandelt. Über geeignete Ansätze für die magnetische Leitfähigkeit des Luftraums und die Strombeläge werden die Luftspaltfelder ermittelt. Mit diesen lassen sich die mit den einzelnen Stromkreisen verketteten magnetischen Flüsse bestimmen. Aus den stationären Lösungen der Spannungsdifferentialgleichungen ergeben sich die Bestimmungsgleichungen für die Diagrammvektoren der Ströme. Über den Drehschub lassen sich das asynchrone Drehmoment und die Amplitude des Pendelmoments der doppelten Schlupffrequenz berechnen. Die experimentelle Überprüfung an einem 3000 KW Synchronmotor zeigt eine recht gute Übereinstimmung zwischen gerechneten und gemessenen Größen.
    Type of Medium: Electronic Resource