Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA , and 9600 Garsington Road , Oxford OX4 2XG , UK . : Blackwell Publishing, Inc.
    Annals of noninvasive electrocardiology 10 (2005), S. 0 
    ISSN: 1542-474X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: Patients with implantable devices are generally not permitted to undergo magnetic resonance imaging (MRI) because of potentially deleterious interactions. Little has been reported regarding the safety and effects of MRI scanning of patients with implantable loop recorders (ILRs). We evaluated the safety of scanning patients with ILRs and the output of the ILR after undergoing MRI. Methods: Ten patients underwent 11 MRI scanning events. All patients had Reveal Plus (Medtronic, Minneapolis, MN) ILRs. Seven cranial, two lumbar-spine, one shoulder, and one knee MRI were performed. All of the MRIs were performed with the understanding that the patient had an ILR. In each patient, the ILR was cleared moments before the scan and the integrity of the signal and time date stamp were verified. The devices were reinterrogated immediately after MRI in 10 patients and two days post MR scanning in one patient. Each patient was questioned post MRI regarding any symptoms experienced during the scan. Results: Both tachy and bradyarrhythmias appeared as artifacts as a result of ILR exposure to MRI. Post MRI, none of the ILRs showed diminished signal integrity, altered programmed parameters, diminished battery status, inability to communicate or be reprogrammed. No sensations of tugging or warmth at the implant site were noted. Conclusion: MRI was performed in ILR patients without harm to the patient or permanent damage to the ILR. MRI scanning of the Reveal appears safe. Artifact mimicking an arrhythmia was common, however, and must be excluded in any ILR patient undergoing MRI to avoid mistakenly attributing a syncopal episode, or palpitations to the artifacts produced from MRI exposure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: BAILIN, S.J., et al .: Bachmann's Bundle Versus Right Atrial Appendage Capture. The tissue in the high intraatrial septum in the region of Bachmann's Bundle (BB) exhibits electrophysiological properties that differ from the right atrial appendage (RAA). As BB pacing emerges as an alternative to RAA pacing, the feasibility of using automatic capture recognition technology in this location should be examined. At implant, active-fixation leads were consecutively placed in the RAA, then the BB in 18 patients (55.5% men, mean age 77.1 ± 9.1 ). There was no significant difference between BB and RAA in the average capture threshold (1.12 vs 1.77 V, P = 0.09), sensing threshold (3.85 vs 3.69 mV, P = 0.84), impedance (508 vs 529 Ohms, P = 0.64), evoked response (1.78 vs 1.67 mV, P = 0.83), and polarization (0.41 vs 0.46 mV, P = 0.84) between. The difference in tissue characteristics was not associated with a different evoked response measured by the ventricular capture recognition algorithm. Based on the analogous evoked response and polarization values, capture recognition technology designed for the atrium will most likely be applicable at both pacing sites. (PACE 2003; 26[Pt. II]:264–267)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Pacing and clinical electrophysiology 23 (2000), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A 55-year-old woman with a history of resected atrial myxoma with residual patched atrial septal defect (ASD) underwent a successful radiofrequency (RF) ablation of reentry atrial tachycardia. She presented with progressive dyspnea 5 days later. Transesophageal echocardiography revealed a 1-cm right atrial mass attached to the intra atrial septum at the ablation site. Repeat study after anticoagulation for 5 weeks showed complete resolution of the thrombus. Thrombus formation at the site of RF ablation is a potential complication that may require aggressive anticoagulation. Patients with patched ASD might be at higher risk.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 6 (1995), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: TdP and Complete Heart Block. Introduction: To determine whether an increased female gender susceptibility to torsades de pointes (TdP) may exist in a clinical model of bradycardia- induced long QT syndrome, we investigated reported cases of TdP associated with acquired complete heart block. Methods and Results: Seventy-two cases reported in the medical literature dating from 1941 through 1993 were identified, all describing TdP or “transient ventricular tachycardia/fibrillation” (to include those cases reported prior to the use of TdP terminology) in the setting of acquired complete heart block unassociated with QT prolonging drugs. Expected female prevalence in complete heart block was estimated at 52%, based on projections derived from 206,016 hospital discharges in the National Inpatient Profile (Commission on Professional and Hospital Activities, Ann Arbor, MI), over the years 1985 through 1992. During complete heart block, mean heart rate was 37 beats/min in both sexes (combined n = 43), and absolute QT interval ranged from 0.52 to 0.88 seconds, with a mean of 0.68 seconds (n = 25). Female prevalence among patients with TdP during complete heart block was greater than expected: 72% for all studied cases (P 〈 0.001); 70% (P 〈 0.04) and 74% (P 〈 0.02) among those reported prior to (n = 35) and during or alter (n = 37) 1980, respectively; 73% (P 〈 0.03) among those with documented normokalemia (n = 26); and 68% (P = 0.2) among those with a prolonged QT interval and known polymorphic VT (i.e., unequivocal TdP; n = 25). Conclusion: Despite inherent limitations of this retrospective study, the data are consistent in suggesting a greater than expected female prevalence among patients with TdP related to complete heart block. This finding lends support to a broadening concept of increased susceptibility of women to the development of TdP in various settings of QT prolongation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA . : Blackwell Science Inc
    Journal of interventional cardiology 16 (2003), S. 0 
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We report the case of a patient with atrioventricular nodal reentry tachycardia (AVNRT), who was found to have obstruction of the inferior vena cava (IVC) by a calcified mass during an electrophysiologic study (EPS). Subsequently, complete EPS was performed via a combined right internal jugular and subclavian venous access. Successful radiofrequency catheter ablation of the fast pathway was performed via the unconventional right subclavian venous route. (J Interven Cardiol 2003;16:377–380)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...