Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Materialart
Erscheinungszeitraum
  • 1
    ISSN: 1540-8167
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Ablation of Atrial Fibrillation. Introduction: Atrial fibrillation (AF) is often refractory to antiarrhythmic drugs, and patients who are intolerant of AF may require the maze operation for cure. As a less Invasive alternative, a catheter-based, right atrial compartmentalization procedure was evaluated. Methods and Results: Twelve patients with AF refractory to Class I and III antiarrhythmic drugs were studied. Four linear right atrial radiofrequency ablations were performed, from superior to inferior vena cava in the posterior wall and interatrial septum, anteriorly from the superior vena cava to the tricuspid annulus through the appendage, and across the tricuspid valve-inferior vena cava isthmus. The radiofrequency catheter was dragged along each line three to four times, until the atrial electrogram amplitude decreased by 75% and there was bidirectional conduction block in the tricuspid valve-inferior vena cava isthmus. One complication occurred: sinus node dysfunction requiring a pacemaker. Eight patients were discharged from the hospital on no antiarrhythmic drugs, and four were discharged on previously ineffective antiarrhythmic drugs. Total duration of follow-up was 21.3 ± 11.2 months. Four patients discharged on previously ineffective antiarrhythmic drugs had no recurrence of AF. One patient discharged off antiarrhythmic drugs had no recurrence of AF. Seven patients discharged off antiarrhythmic drugs had recurrent AF by 12.6 ± 13.0 months (median 6, range 1 to 39); 3 of these 7 responded to previously ineffective antiarrhythmic drugs without further AF and 4 did not. Thus, 8 of 12 patients (67%) had suppression of AF after ablation on previously ineffective medication or no medication. Conclusion: Right atrial compartmentalization may alter the substrate for AF, thus improving the efficacy of previously ineffective antiarrhythmic drugs. Because it is relatively safe, it may be a reasonable adjunctive intervention to maintain sinus rhythm in patients with drugrefractory AF.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1540-8167
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Slower Conduction in the TV-IVC Isthmus. Introduction: In human type I atrial flutter, the electrophysiologic substrate is unclear. In order to determine if slow conduction is mechanistically important, we evaluated conduction velocity in the tricuspid valve-inferior vena cava (TV-IVC) isthmus, right atriai free wall, and interatrial septum in patients with and without a history of atrial flutter undergoing electrophysiologic study. Methods and Results: Nine patients with (group 1) and nine without a history of type I atrial flutter (group 2) were studied. Conduction time (msec) in the right atrial free wall. TV-IVC isthmus (bidirectional), and interatrial septum was measured during pacing in sinus rhythm at cycle lengths of 600, 500, 400, and 300 msec from the low lateral right atrium and coronary sinus ostium. Conduction velocity (cm/sec) was calculated by dividing the distance between pacing electrodes and sensing electrodes (cm) by the conduction time (sec). Conduction velocity was slower in the TV-IVC isthmus in group 1 (range 37 ± 8 to 42 ± 8 cm/sec) versus group 2 (range 50 ± 8 to 55 ± 9 msec) at all pacing cycle lengths (P 〈 0.05). However, conduction velocity was not different in the right atrial free wall or interatrial septum between groups 1 and 2. Conduction velocity was also slower in the TV-IVC isthmus than in the right atrial free wall and interatrial septum in group 1 patients, at all pacing cycle lengths (P 〈 0.05). Atrial flutter cycle length correlated with total atrial conduction time (r ≥ 0.832, P 〈 0.05). Conclusion: Slow conduction in the TV-IVC isthmus may be mechanistically important for the development of human type I atrial flutter.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...