Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1619-7089
    Keywords: Monoclonal antibodies ; Avidin ; Biotin ; Tenascin ; Emission tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The imaging of cerebral gliomas with radiolabelled monoclonal antibodies (MoAbs) has been previously reported. However, previous studies have been hampered by the drawback of a low tumour to non-tumour ratio. In order to overcome this problem we have developed a three-step pre-targeting method using the avidin-biotin system. The rationale of this technique consists in vivo labelling of biotinylated MoAbs targeted onto tumour deposits, when most of the unbound antibodies have been cleared from the bloodstream as avidin-bound complexes. The anti-tenascin MoAb BC2, specific for the majority of gliomas, was biotinylated and 1 mg was administered i.v. in 20 patients with histologically documented cerebral lesions. After 24–36 h, 5 mg avidin was injected i.v. followed 24 h later by a third i.v. injection of 0.2 mg PnAO-biotin labelled with 15–20 tnCi technetium-99m. No evidence of toxicity was observed. Whole-body biodistribution was measured at 20 min, 3 h and 5 h post-injection. [99mTc]PnAO-bio-tin had a fast blood clearance and was primarily excreted through the biliary system. A dedicated single-photon emission tomography system was used to acquire brain tomographic images 1–2 h after the administration of [99mTc]PnAO-biotin. Tumours were detected in 15/18 glioma patients with a tumour to non-tumour ratio of up 14:1. This three-step method, based on the sequential administration of anti-tenascin MoAb BC2, avidin and [99mTc]PnAO-biotin, can support computed tomography or magnetic resonance imaging for the diagnosis and follow-up of patients with glioma. Further studies are required to evaluate the potential of this technique for therapeutic application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Monoclonal antibodies ; Avidin ; Biotin ; Tenascin ; Emission tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The imaging of cerebral gliomas with radiolabelled monoclonal antibodies (MoAbs) has been previously reported. However, previous studies have been hampered by the drawback of a low tumour to non-tumour ratio. In order to overcome this problem we have developed a three-step pre-targeting method using the avidin-biotin system. The rationale of this technique consists in vivo labelling of biotinylated MoAbs targeted onto tumour deposits, when most of the unbound antibodies have been cleared from the bloodstream as avidin-bound complexes. The anti-tenascin MoAb BC2, specific for the majority of gliomas, was biotinylated and 1 mg was administered i.v. in 20 patients with histologically documented cerebral lesions. After 24–36 h, 5 mg avidin was injected i.v. followed 24 h later by a third i.v. injection of 0.2 mg PnAO-biotin labelled with 15–20 tnCi technetium-99m. No evidence of toxicity was observed. Whole-body biodistribution was measured at 20 min, 3 h and 5 h post-injection. [99mTc]PnAO-bio-tin had a fast blood clearance and was primarily excreted through the biliary system. A dedicated single-photon emission tomography system was used to acquire brain tomographic images 1–2 h after the administration of [99mTc]PnAO-biotin. Tumours were detected in 15/18 glioma patients with a tumour to non-tumour ratio of up 14:1. This three-step method, based on the sequential administration of anti-tenascin MoAb BC2, avidin and [99mTc]PnAO-biotin, can support computed tomography or magnetic resonance imaging for the diagnosis and follow-up of patients with glioma. Further studies are required to evaluate the potential of this technique for therapeutic application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...