Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 97 (1992), S. 2359-2371 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Two semiempirical potentials are used to interpret the vibration–orientation spectrum of the hydrogen chloride–RG* dimers trapped in RG matrices (RG*, RG=Ar, Kr, Xe). The geometries of these dimers are calculated by including matrix relaxation and compared to those observed in the gas phase. It is shown that dimers in matrices can have radial and angular configurations very different from those reported in the gas phase, which have been used to fit potential parameters. The main features of the experimental spectrum of the trapped dimers are satisfactorily interpreted on the basis of one or the other potential. But none can lead to a universal interpretation of the infrared spectra of all the dimers. Arguments are developed on the main causes of discrepancies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 226 (1997), S. 205-210 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Although much progress was made by using high purity gemanium detectors for direct measurement of239Pu in man, the improvement of lung spectroscopy sensitivity remains a challenge. Previous work showed that passivated implanted planar silicon detectors could provide an alternative by combining high-energy resolution at room temperature and planar geometry with large detection arrays. This paper reports on the status of this research based on the characterisation of 3×3 cm2 and 6×3 cm2 strip silicon detectors. Furthemore, the possibility to apply such detectors towards other monitoring problems for accidental situations such as the direct measurement of small contaminated surfaces was investigated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...