Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 39 (1988), S. 499-503 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Verhinderung von Lochkorrosion in Wasserleitungen aus Kupfer durch Zugabe von HydrogencarbonatKupferrohre werden für Wasserleitungen viel verwendet und verhalten sich im allgemeinen sehr gut. In Ausnahmefällen kann es jedoch zu Lochkorrosion und sogar Durchlöcherung kommen. Zwar hat man 3 Arten der Lochkorrosion (I-III) nachweisen können, doch sind die Ursachen und die Mechanismen bisher noch nicht völlig geklärt. Aufgrund der Untersuchungen von Schadensfällen, Modellversuchen und thermodynamischen Berechnungen sowie Praxisversuchen haben sich Hinweise dafür ergeben, daß Wässer, die in Kupferrohren Lochkorrosion hervorrufen können, durch Erhöhen des Hydrogencarbonatgehalts weniger aggressiv gemacht werden können. Bei der Behandlung der Wässer sollte die folgende Wasserzusammensetzung angestrebt werden: - pH mindestens 7,- Hydrogencarbonatgehalt von mindestens 70 mg/l, vorzugsweise 100 mg/l- möglichst niedriger Sulfatgehalt, mindestens jedoch unter dem Hydrogencarbonatgehalt.
    Notes: Copper pipes are extensively used for tap water installations and generally perform well. Exceptionally, however, copper pipes are perforated due to pitting. Three main types of pitting (I, II and III) have been identified, but as for the causes and the mechanisms these have not yet been fully clarified.Through case studies, model experiments, thermodynamic calculations, and service tests, evidence has been obtained that waters having a pitting propensity for copper pipes can be made less corrosive by an increase of the HCO3- content. On water treatment the following water composition should be aimed at: - a pH value of at least 7- an HCO3- content of at least 70 mg/l, preferably 100 mg/l- as low SO42- content as possible, or at least lower than the HCO3- content (both in mg/l).
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...