Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Neuromonitoring ; SSEP ; NIRS ; Transkonjunktivale Sauerstoffspannung ; Selektive Shunteinlage ; Key words NIRS ; Selective shunting ; Neuromonitoring ; SSEP ; Conjunctival oxygen tension
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract The principle of, “selective shunting” during carotid endarterectomy requires a special concept to monitor neuronal function. The valence of the oxymetric methods, “near-infrared” spectroscopy (NIRS) and conjunctival oxygen tension (pcjO2) was determined with the reference method somatosensory evoked potentials (SEP). Methods. In 41 patients undergoing reconstructive surgery on the internal carotid artery, recordings of the different methods were obtained under control, during carotid occlusion and during reperfusion. Cerebral ischemia was assumed if a complete loss of SEP appeared and an intraluminal shunt was placed. Conjunctival oxygen tension was measured continuously and simultaneously on the ipsi- and contralateral eye. Results. In comparison to the reference method (SEP) the sensitivity and specificity of NIRS was 80% and 94%, respectively. The occlusion induced reduction of NIRS appeared 6.5±3.2 min earlier than the corresponding loss of SEP. Biocular determination of conjunctival oxygen tension was not able to detect hypoperfusion dependent ischemia during carotid occlusion. Conclusion. During carotid endarterectomy the measurement of conjunctival oxygen tension is not useful to detect cerebral ischemia. The use of NIRS as a single neuronal monitor is not appropriate to perform, “selective shunting”. In contrast to SEP, however, NIRS is characterized by its rapid changes immediately following carotid occlusion. This non invasive method is likely to complete the standard method SEP in a modified monitoring concept of neuronal function during carotid endarterectomy.
    Notes: Zusamenfassung Ziel der Arbeit. Das Prinzip der selektiven Shunteinlage bei Karotisendarterektomien erfordert ein differenziertes Neuromonitoringkonzept. Die Wertigkeit der oxymetrischen Verfahren “near-infrared” Spektroskopie (NIRS) sowie des transkonjunktivalen Sauerstoffpartialdrucks (pcjO2) wurden anhand der Referenzmethode SSEP bestimmt. Methodik. Bei 41 Patienten mit elektiver Karotis-TEA wurden diese Neuromonitoringparameter unter Kontrollbedingungen, während Karotisokklusion und in der Reperfusionsphase bestimmt. Der vollständige Verlust der SSEP-Amplitude war das Kriterium zur Shunteinlage. Die Messung des transkonjunktivalen Sauerstoffpartialdrucks erfolgte zeitgleich auf dem ipsi- und kontralateralen Auge. Ergebnisse. Im Vergleich zur Referenzmethode SSEP zeigte NIRS eine Sensitivität und Spezifität von 80% und 94%. Die okklusionsbedingte Reduktion von NIRS zeigte sich im Mittel 6,5±3,2 min früher als die entsprechenden Veränderungen der SSEP-Werte. Die biokulare Bestimmung des transkonjunktivalen Sauerstoffpartialdrucks konnte die hypoperfusionsbedingte Ischämie nicht detektieren. Schlußfolgerung. Die transkonjunktivale Sauerstoffspannung ist bei Karotisendarterektomien als Neuromonitoringverfahren ungeeignet. Die alleinige Indikation zur Shunteinlage ist mittels NIRS nicht möglich. NIRS ist jedoch im Unterschied zu den SSEP durch eine rasche Änderung nach Karotisokklusion charakterisiert. NIRS ist als nicht invasive Methode geeignet, das Standardverfahren SSEP in einem modifizierten Neuromonitoringkonzept zu ergänzen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Tagesklinik ; Anästhesie-Informations-Management-System (AIMS) ; Dokumentation ; Unvorhergesehene stationäre Aufnahme ; Ambulantes Operieren ; Keywords Day care unit ; Anesthesia information management system (AIMS) ; Documentation ; Unanticipated admission ; Ambulatory surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract From January 1997 until June 1999, the complete durations of stay of 3152 outpatients were entered into a computerized documentation system. The scope of the data entry went from patient admission to patient release. The objective was to determine the usefulness of the anaesthesia information management system (AIMS) in producing complete and high-quality documentation in the field of outpatient operations. Some aspects and results from routine work are presented here. Method. The system was installed in eight bedside computers, in addition to a further client connected to the existing AIMS via Ethernet. Patient medical courses were documented both preoperatively and postoperatively in outpatient bedsides until their discharge or admission. The online documentation software NarkoData (Version 4, Imeso GmbH, Hüttenberg, Germany) was used to document and store patient data in a database. This program contains all relevant information concerning the course of anaesthesia and outpatient duration of stay, including application of drugs, vital signs, observation times, and medical findings as well as the data sets of the German Society of Anaesthesiology and Intensive Care Medicine (DGAI), ICD, and ICPM. Data was analyzed by exporting from the database into a statistical program using “structured query language.” Results. Data sets of 3152 outpatients were entered into the online documentation software. Most (54.2%) of the ambulatory surgical procedures were performed by the Department of Traumatology. General Surgery followed with 16.0%, and Urology managed 9.5% of the cases. The most frequent ambulatory surgical procedures were: diagnostic arthroscopy (923, 31.2%), removal of osteosynthetic material (410, 13.8%), and circumcision (250, 8.4%). Anesthesia procedures consisted of inhalative (38.6%, n=1218) and intravenous anesthesia (IVA) (29.9%, n=938). In 22.6% (713) of the cases, regional anaesthesia was performed. The average postoperative observation time was 289.2±140.1 minutes. One hundred sixty-nine patients (5.4%) were unexpectedly admitted to overnight care. The decision to admit patients to normal wards took place within the first 3 postoperative hours in 51.9% of the cases. Conclusion. The AIMS described above is sufficient in documenting the entire care process of patients in a day care unit. Integration into the existing AIMS was an important prerequisite for the integrity of the documentation chain. This allowed for a sensitive communication with other clinical data processing systems. The quality of documentation and flow of information at the workplaces in the day care unit were increased, similarly to other anaesthesiological workplaces in the hospital. Medical and administrative data and information for analyses of clinical processes are possible with such tools.
    Notes: Zusammenfassung Von Januar 1997 bis Juni 1999 wurde der komplette Aufenthalt aller tageschirurgischen Patienten, von der Aufnahme bis zur Entlassung, mit einem computergestützten Dokumentationssystem erfasst. Einzelne Aspekte und Ergebnisse aus dem Routinebetrieb sollen mit der Fragestellung vorgestellt werden, ob ein Anästhesie-Informations-Management-System (AIMS) geeignet ist, auch im Bereich des “Ambulanten Operierens” eine umfassende und qualitativ hochwertige Dokumentation zu gewährleisten. Methodik. Die Installation des Systems erfolgte durch Einbindung von 8 Bettplatz-Computern und eines weiteren Clients über das Intranet in das bestehende AIMS. An den tagesstationären Bettplätzen wurden Patientendaten prä- und postoperativ bis zur Entlassung oder Verlegung der Patienten mit der Online-Dokumentationssoftware NarkoData® Version 4 (Imeso GmbH, Hüttenberg) dokumentiert und in einer Datenbank gespeichert. Dieses Programm erfasst sämtliche für den Narkoseverlauf und tagesstationären Aufenthalt relevanten Informationen, u. a. Medikamentenapplikationen, Vitaldaten, Überwachungszeiten, Befunde sowie den Kerndatensatz der DGAI, ICD 9 und ICPM. Zur Auswertung wurden die Daten mittels der “Structured Query Language” (SQL) aus der Datenbank in ein Statistikprogramm exportiert. Ergebnisse. Die Datensätze von 3.152 tagesstationären Patienten wurden mit der Online-Dokumentationssoftware erfasst. Die häufigsten tageschirurgischen Operationen führte mit 54,2% der Fälle die operierende Fachabteilung Unfallchirurgie durch, gefolgt von der Allgemeinchirurgie mit 16,0% und der Urologie mit 9,5%. Die häufigsten tageschirurgischen Eingriffe waren diagnostische Arthroskopie (923, 31,2%), Entfernung von Osteosynthesematerial (410, 13,8%) und die Zirkumzision (250, 8,4%). Von anästhesiologischer Seite kamen zumeist die Inhalationsnarkose (38,6%, n=1218) und die intravenöse Anästhesie (IVA; 29,9%, n=938) zum Einsatz. Eine Regionalanästhesie wurde in 22,6% der Fälle (n=713) durchgeführt. Die durchschnittliche postoperative Überwachungszeit betrug 289,2±140,1 min. 169 Patienten (5,4%) wurden ungeplant stationär aufgenommen. Die Entscheidung zu einer stationären Aufnahme wurde bei 50,9% der stationär aufgenommenen Patienten intraoperativ oder in den ersten drei postoperativen Stunden gefällt. Schlussfolgerung. Das beschriebene AIMS ist geeignet, den gesamten Behandlungsprozess eines Patienten in einer operativen Tagesklinik zu dokumentieren. Die Integration in das bestehende System stellte sich als wesentliche Voraussetzung für die Integrität der Dokumentationskette heraus und ermöglicht eine sinnvolle Kommunikation mit anderen klinischen Datenverarbeitungssystemen. Wie auch im Bereich der Anästhesie konnten die Dokumentationsqualität und der Informationsfluss am Narkosearbeitsplatz gesteigert werden. Neben medizinischen und administrativen Daten stehen Informationen für die Analyse klinischer Prozesse zur Verfügung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-0509
    Keywords: Foreign bodies ; Sponges, towels ; Surgery, complications ; Abdomen. abscess ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The diagnosis of retained sponges and towels a year or more after surgery is often very difficult. We describe the computed tomographic (CT) findings in 4 patients with this complication; 2 cases of retained sponges and 2 cases of retained towels. While the CT appearance of the retained sponges was not specific, the particular appearance of the retained towels had not been previously described. This appearance is characteristic enough to suggest the correct diagnosis before reoperation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Marine biology 7 (1970), S. 273-284 
    ISSN: 1432-1793
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé 1. Cette étude tente de définir les modalités d'emploi du chalut pélagique Isaacs-Kidd 10 pieds en vue d'un échantillonnage quantitatif des populations en place. 2. Que ce soit pour des croisières saisonnières, géographiques, ou pour des études en stations fixes, l'absence de systéme ouvrant-fermant fonctionnant de façon satisfaisante et la conception même du filet ne permettent de réaliser que des traits obliques. Théoriquement, ce type de trait échantillonne de la même façon les différentes couches d'eau, permettant ainsi soit la comparaison directe de traits réalisés à la même profondeur, soit la comparaison par la méthode des différences, de traits effectués à diverses profondeurs. 3. La mise au point progressive du protocole a porté sur 1500 traits réalisés au cours de 16 croisières. 4. Seule l'utilisation conjointe de 2 enregistreurs fournissant, le premier la profondeur en fonction du temps, le second la profondeur en fonction de la distance parcourue par le filet, a permis de définir parfaitement le profil des traits. 5. Il est apparu rapidement qu'il était impossible de réaliser un trait symétrique dans le temps et l'espace, l'action du dépresseur en début de virage provoquant un palier dans la partie inférieure du profil, d'où un suréchantillonnage d'une couche par rapport aux autres. Afin de minimiser cet effet et de réduire les fortes tensions auxquelles était soumis le câble en zone équatoriale à cause de la stratification de courants de l'ordre de 1 à 2 noeuds, on a réduit la surface active du dépresseur par suppression d'une partie de la tôle. Cette modification s'étant avérée insuffisante, il a fallu, dans un dernier stade laisser le filet plonger de lui-même pendant un certain temps en fin, de filage, treuil stoppé et bateau ralenti. 6. On obtient ainsi un échantillonnage à vitesses différentes à la descente et à la remontée, ce qui fait varier l'évitement des organismes, mais comme ces vitesses sont constantes, chaque couche est, au total, traversée de la même manière par le filet. Sur le plan méthodologique, il semble que peu de progrés puissent être réalisés avec le seul matériel utilisé dans cette étude. Une nette amélioration interviendra sans doute quand on disposera en routine d'appareils permettant de connaître en continu, sur le pont, la position et la vitesse de l'engin, mais la localisation exacte de la capture de chaque organisme dans le temps et l'espace ne pourra être connue qu'à l'issue de la mise en oeuvre de matériel nouveau dans ses principes et ses performances.
    Notes: Abstract This paper describes the use of the 10 foot Isaacs-Kidd midwater trawl as a quantitative sampler of the micronektonic standing crop. The use of this gear without an opening-closing mechanism made it necessary to sample by means of oblique hauls. This study, which includes not less than 1500 hauls, is directed towards introducing some degree of uniformity in operating this device so that valid comparisons can be made between catches from oblique hauls made at similar depths, as well as oblique hauls made at different depths. It is emphasized that information must be obtained on the tow path using depth-time and depth-distance recorders simultaneously. As the maximum depth depends largely upon variations in towing speed, it is important to be able to control ship speed carefully. As net speed is a significant factor in avoidance and escapement, care should be taken to sample each layer in an identical manner. The procedure defined here mainly involves (a) modifications of the depressor; (b) application of the winch brake after all the cable has been paid out, during the time required for the trawl to attain maximum depth; (c) paying out and hauling in at high speed by the winch. Resulting hauls show a nearly oblique tow path. Sampling velocities of the net are the same for all water layers: slow during descent, fast during ascent. This allows valid comparisons to be made between a series of hauls. Nevertheless, future progress in quantitative sampling depends largely upon technical improvements, and the evolution of new devices and approaches.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Marine biology 4 (1969), S. 139-142 
    ISSN: 1432-1793
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé 1. Les auteurs décrivent une méthode permettant, par centrifugation, d'essorer rapidement, sans les détériorer, les organismes du micronecton en vue de pesées humides reproductibles. La vitesse de rotation correspondant à une accélération centrifuge de 56 g est déterminée comme éliminant l'eau interstitielle retenue par des billes de verre. Une durée de centrifugation de 1 min est retenue car elle restitue les organismes en parfait état. 2. La reproductibilité de la méthode est testée sur les billes de verre et sur divers groupes d'organismes. Indépendante de la taille des échantillons, elle varie suivant les organismes. Elle est d'autant meilleure que leur teneur en eau est plus faible. 3. Cette méthode permet done d'évaluer des poids humides dans de bonnes limites de reproductibilité pour les organismes à teneur en eau moyenne ou faible et n'introduit pas de variabilité supplémentaire pour les organismes riches en eau pour lesquels les variations de pertes d'eau interne dues aux manipulations sont prépondérantes.
    Notes: Abstract A method of centrifugation to remove interstitial water before wet weight measurements is presented. Speed and duration that do not injure organisms have been selected. In order to test the method, the relative standard error is calculated; it increases with increased water content of organisms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Marine biology 6 (1970), S. 200-212 
    ISSN: 1432-1793
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract This paper deals with the selection of the 10-foot Isaacs-Kidd midwater trawl, 4 mm in mesh size, which terminates in a fine-mesh section of 1 mm mesh aperture. It is emphasized that this finer mesh adds a large fraction of small animals to the main catch, This fraction has been estimated from comparisons between catches collected (1) with the above gear, (2) with the above gear terminating in a 4 mm mesh cod-end, (3) with the 1 mm mesh cod-end used alone as a net. It is demonstrated that escape through 4 mm meshes is a function both of hauling duration and of vertical distribution of organisms. The experimental part of this work has been carried out on crustaceans.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Marine biology 8 (1971), S. 238-242 
    ISSN: 1432-1793
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé 1. Cette étude décrit les différents traitements auxquels sont soumises les récoltes micronectoniques en vue de leur étude qualitative et quantitative. 2. A bord du bateau, aucune manipulation particulière n'est effectuée, si ce n'est, après le lavage du filet et le vidage du collecteur, le stockage dans une solution de formol neutralisé à 10%. Au laboratoire, les récoltes font l'objet d'une succession de traitements mécaniques qui s'effectuent dans un courant d'eau. 3. Le passage dans une colonne de 1,60 m de hauteur permet, par différence de densité, d'isoler les organismes gélatineux; la fraction restante passe alors sur une suite de tamis, dont le fond est constitué de baguettes de verre régulièrement espacées, qui permettent d'isoler des fractions homogènes en tailles. 4. Le tri manuel, qui aboutit à la séparation par taxa puis aux différentes pesées, s'en trouve grandement facilité, les organismes étant bien séparés les uns des autres et leurs tailles équivalentes dans chaque fraction. 5. Il semble qu'à l'avenir des efforts importants devront être faits dans cette voie qui permet, de traiter un grand nombre de prélèvements du fait d'un considérable gain de temps.
    Notes: Abstract This paper deals with some mechanical treatments of micronektonic samples which enable easier sorting into taxa. At sea, it is only possible to hose the net intensively before being brought on board ship; organisms are then washed into a bucket, the bucket emptied, and the samples preserved in a 10% buffered formaldehyde solution. A laboratory method for sorting gelatinous organisms based on differential specific gravity is described. The sorter consists of a cylinder 1.60 m high, supplied with running water. The remaining fraction is then sorted into 3 size groups. The device consists of a set of grills made from equidistant glass rods, through which organisms are sieved by the reciprocating motion of the grills into a large jar filled with running water. As this method results in higher sorting efficiency, it is recommended that further research be made in this direction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...