Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 103 (1995), S. 7700-7707 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: A new scheme for performing high-resolution kinetic energy measurements on single quantum states of NO is described. Laser excitation of the a 4Π(ν=13–15) and b 4Σ−(ν=3)←X 2Π(ν=0) spin-forbidden bands has been used to produce NO a 4Π, either by direct excitation or after excitation to NO b 4Σ− followed by b→a emission. The sensitivity is compared to previous experiments on CO, employing the forbidden Cameron system. In the course of these experiments, three previously unknown vibronic levels of the a 4Π state were observed for which high precision molecular constants have been obtained. The derived molecular constants have been used to construct a chemically accurate RKR potential for the a 4Π state to within 0.2 eV of the dissociation limit. In addition, the electric dipole moments for the a 4Π(ν=13–14) levels have been determined. By comparing the experimental results with two ab initio calculations, the polarity of the dipole moment of the a 4Π state at equilibrium separation could be determined. A set of supplementary molecular beam laser-induced fluorescence studies on the b 4Σ−(ν=3)←X 2Π(ν=0) band were also carried out. These allowed the fluorescence lifetime of b 4Σ−(ν=3) state to be obtained under collision-free conditions and the electronic origin of the quartet manifold to be determined within 0.03 cm−1. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The radiation to be detected is passed through a cell of carbon dioxide which acts as a filter and in which the cell pressure is varied sinusoidally at 15 Hz. The amplitude of the resulting signal selected at this frequency is a measure of the intensity of incident radiation from very narrow ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 97 (1993), S. 3944-3955 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 41-47 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A phase fluorometer based on a low-cost and versatile high-frequency modulated light source and a fast gain-modulated photomultiplier is described. The apparatus is particularly well-suited to high-sensitivity frequency-domain fluorescence measurements requiring ultraviolet excitation. The system is very compact since it features a directly modulated light source, a miniature photomultiplier tube, and an rf synthesizer on a PC board. Equipped with a suitable fiber optic probe sensor, the device has potential as a portable unit for a wide range of remote sensing applications. The lamp can be modulated at frequencies up to 120 MHz and the phase fluorometer has been tested at up to 70 MHz with a range of fluorescent lifetime standards containing quinine sulfate quenched with sodium chloride. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 3744-3749 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The construction and testing of a dual-channel photon correlator is reported for the frequency domain imaging of fluorescence lifetimes using photon-counting detection. A light source modulated at radio frequency excites fluorescence, which is detected using an imaging single-photon detector. After discrimination, single-photon events are processed in parallel by the correlation circuit, the purpose of which is to allow both the mean phase delay and the demodulation of fluorescence to be calculated relative to a reference signal derived from the modulated excitation source. Outputs from the correlator are integrated in a computer, resulting in accumulation of images which have been statistically filtered by sine and cosine transforms, and which can be manipulated within the computer to generate a resultant image where contrast depends on fluorescence lifetime rather than fluorescence intensity. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 48-51 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Phase fluorometry and fluorescence lifetime imaging require a source of exciting light which can be modulated at radiofrequency. This is difficult to achieve with reasonable efficiency using conventional light sources with external modulators such as Pockels cells, while laser sources are limited in wavelength tunability. In this paper a low-cost and versatile high-frequency modulated light source is described which is well suited to frequency-domain fluorescence measurements. The source is a modified deuterium arc lamp which can be driven directly at frequencies up to approximately 130 MHz, and which provides a highly stable source of ultraviolet and visible light. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] This article describes the temperature profiles through the atmosphere that are being obtained from the radiometer on Nimbus ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The radiometer1"3 has six channels, each accepting infrared radiation emitted by carbon dioxide in the atmosphere below the satellite at wavelengths of approximately 15 urn. The radiation measured by channel A originates in a layer approximately 20 km thick centred at the 2 mbar (42 km) level, ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The SCR on Nimbus 5 is a more advanced instrument and possesses: (1) It has a narrow field of view, equivalent to ~25 km resolution at the Earth's surface, which means that observations of areas which are cloud free or which have uniform cloud cover are more likely than with Nimbus 4. (2) It has ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromosome research 4 (1996), S. 261-263 
    ISSN: 1573-6849
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Fluorescence microscopy is an important tool for biological research, in part because of the extremely high detection sensitivity that can be achieved, but also because fluorescent molecules can be used as probes on account of their environmental responsiveness, for example to measure intracellular pH or metal ion concentration. Unfortunately, the environmental sensitivity can sometimes be a source of problems because of enhancement of ‘quenching’, which can make it very difficult to relate emission intensity to the amount of fluorophore present. The measured intensity is essentially proportional to the product of the amount of fluorophore present in the sample and the local quantum yield of the fluorophore (the quantum yield can be thought of as the probability that an excited molecule decays by fluorescence emission rather than by other non-radiative processes). This is a particular difficulty in an environment such as a cell or tissue slice in which quantum yield and fluorophore concentration can both vary within the sample. Ideally we would wish to be able to measure the quantum yield of fluorescence as well as the fluorescence intensity, as this would allow environmental effects to be compensated for. Unfortunately, this is not at all easy, and indirect means to achieve the same goal are more appropriate. A recently introduced technique,fluorescence lifetime imaging (Morganet al. 1992, Wanget al. 1992), offers one such means to improve quantification of fluorescence microscopy. In addition, as will be explained, the technique offers the prospect of significantly improving detection sensitivity in appropriate circumstances.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...