Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Electrochimica Acta 14 (1969), S. 889-895 
    ISSN: 0013-4686
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 211 (1966), S. 143-145 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Zusammenfassung Eine einfache Methode für die Bestimmung des Filmkonzentrations-Potentials (FCP) wird beschrieben. Das FCP tritt auf, wenn die spezifische Leitfähigkeit des Films kleiner als 10−7 Ω−1 wird. Das Filmkonzentrationspotential steigt mit abnehmenden Werten der spezifischen Filmleitfähigkeit und erreicht ein Maximum für die Annäherung an gleichgroße Werte für ihre spezifische Oberflächenleitfähigkeit.
    Notes: Summary A simple method for determining the film concentration potential (FCP) is described. The FCP appears when the film specific conductance (k f 0 ) 〈 10−7 ohms−1. The FCP increases with decreasing values of the (k f 0 ), reaching to a maximum at (k f 0 ) →k(k s 0 ).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 211 (1966), S. 146-150 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Zusammenfassung 1. Die Leitfähigkeit von Filmen, die an den Wänden einer Glasröhre nach Entleerung durch freies Ausfließen der Flüssigkeit verbleibt, ist aus der Leitfähigkeit der Lösung des Filmes (k b ) und der Oberflächenleitfähigkeit des Glases (k s ) zusammengesetzt. 2. In verdünnten Lösungen giltk s 〉k b , in konzentrierten Lösungenk s 〈k b . Diese Tatsache erlaubt, eine neue Methode zur Bestimmung der Dicke des Films zu erarbeiten, der an der Glaswand verbleibt, und die spezifische Oberflächenleitfähigkeit zu ermitteln (k s 0) 3. Nach freiem Ausfließen der Lösungen besitzt die Dicke der Schicht des Elektrolyten die Größenordnung von 1 bis 2μ nach 30 min Abtropfen. Nach 24 Stunden Abtropfen verbleibt eine Schicht von 0,3 bis 0,4μ. 4. Die Dicke von Filmen viskoser Kolloid-Lösungen ist von der Größenordnung vielerμ. 5. Die Oberflächenspannung hat nur begrenzten Einfluß auf die Filmdicke. 6. Die Bestimmung der Oberflächenleitfähigkeit von Pyrex-Glas ergab Werte von 2,2±0,2·10−9Ω−1
    Notes: Summary 1. The conductivity of the films which remains on the glass tube wall after its emptying and free drainage of the liquid, is composed of conductivities of the solution of the film (k b ) and the surface conductivity of the glass (k s ). 2. In diluted solutionsk s 〉k b , whereas in concentrated solutionsk s 〈k b . This fact permits to elaborate a new method to determine the thickness (h) of the film which remains on the tube wall and the specific conductance of surface (k s 0). 3. After emptying and free drainage of solutions, a film layer of electrolyte solutions of the orderμ: 1–2μ after 30 min drainage and 0.3–0.4μ after 24 h drainage, remains on the tube walls. 4. The thickness of the film of viscous colloidal solutions is of the order of manyμ. 5. The surface tension has only a limited influence on the thickness of the film. 6. The determination of the surface specific conductance (k s 0) of the pyrex glass gave a value of 2.2±0.2×10−9 Ω −1.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 202 (1965), S. 162-164 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Zusammenfassung Der Einflu\ der Porengrö\e auf das Konzentrationspotential an Austauschern und Tonschiefer wurde untersucht. Die Poren-Interstitien wurden homogen aufgeweitet mit Agar-Gel. Im heterogenen Fall wurde Ersatz eines Teils des Austauscher-Diaphragmas durch Filterpapier gewählt. In beiden Fällen verursachte die Vergrö\erung der Poren das Absinken des VerhältnissesE/E max auf Null, wobei die Beziehungen zwischenE/E max unda/a+b exponentiell verlaufen.
    Notes: Summary 1. The influence of pore size on the concentration potential of exchangers and shale was studied. The interstitial pores were enlarged homogeneously by mixing with agar gel, and heterogeneously by substituting part of the exchanger diaphragms with filter paper. 2. In both cases enlarging the pores causes the ratioE/E max to tend to 0, being the relation betweenE/E max anda/a+b exponential.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 254 (1976), S. 50-54 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Zusammenfassung In der vorliegenden Arbeit wird über EMK-Messungen an Filmen aus Montmorillonit berichtet, die als Membranen zwischen Konzentrationszellen eingesetzt sind. Die Filme bestanden aus einer oder aus zwei homogenen Zonen. Im ersten Falle wurden Membranpotentiale gemessen, die der klassischen Membrantheorie mit konstanten Überführungszahlen im Film entsprachen. Im letzteren Falle waren Richtung und Größe der Potentiale abhängig vom Verhältnis der KCl-Konzentrationen außerhalb und innerhalb des Films und von der Differenz der Überführungszahlen der Ionen in den beiden Zonen des Films.
    Notes: Summary By filling and draining a smallU glass tube of 4 cm length and 2 mm in internal diameter with 1 and/or 5 percent montmorillonite suspensions, thin clay films were formed on the internal surface of the tube. These films could be prepared as a single homogeneous zone or as two zones that differ in their clay particle concentration. The films were stable over few minutes and were interposed between two KCl solutions of equal or different concentrations in a concentration cell. Emf measurements across calomel electrodes were carried out as a function of the KCl concentration in and outside the films. Membrane potentials of films having one zone followed classical membrane theory with constant ion transport numbers in the films. The sign and magnitude of the potentials obtained with bizonal clay films were found to depend on the ratio of the KCl concentrations inside and outside the film as well as on the difference in the transport number of the ions in each zone of the film.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...