    Topics: Medicine
    Notes: Benign tumors of smooth muscle origin are rare in the oral cavity. This paper reviews 67 cases from the literature and six previously unpublished cases of oral leiomyoma. Tongue, hard palate and buccal mucosa are the most common sites of this lesion and the vascular leiomyoma or angiomyoma is the predominant histologic type.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral pathology & medicine 8 (1979), S. 0 
    ISSN: 1600-0714
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract. The minor salivary glands in the hard palate and the submandibular gland of the Rhesus monkey were subjected to a liquid nitrogen, direct-spray, one-cycle freeze. A 4-min freeze in the temperature range of –40°C to –60°C was used. The extent of tissue destruction was determined at intervals up to 1 year. Clinically relevant findings resulted and form the basis for subsequent studies by this group of investigators.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 13 (1979), S. 631-643 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Samples of capacitor grade tantalum were surface-treated by a variety of methods. These surface treatments allowed testing of the same basic material which was millfinished, metallurgically polished, electrochemically oxidized, sintered with a porous surface, and glow-discharged. Surface characterization was accomplished by contact angle measurements, Scanning Electron Microscopy, energy-dispensed x-ray analysis, and internal reflection spectroscopy. Subsequent to characterization, the material was surgically implanted in the subperiosteal region of the mandible, the buccal mucosa, and the subcutaneous paravertebral region of the back of Macaca speciosa (stumptail monkey). The tissue reaction at intervals of up to three weeks was evaluated morphologically and ultrastructurally. Significant differences in tissue response were noted at the interfaces with glow-discharge-treated versus lower surface energy samples. Adjacent to the glow-discharge-treated implants, two distinct tissue zones were identified. Zone #1, nearest the implant, exhibited an increased cellularity. This consisted of 4-5 layers of highly active mesenchymal cells or fibroblast-like cells with spindle-shaped nuclei and prominent cytoplasmic features. At various foci along the interface, hyperchromatic nuclear forms were noted to project into the space left by removal of the implant. These observations, coupled with a predominance of intercellular ground-substance material and less collagen at the interface, may indicate some form of bioadhesion. The deeper Zone #2 was 2-3 times as thick and consisted of typical fibroblastic cells with a lamellar configuration, bordered by an occasional delicate-lined space. Independent of implantation site or surface texture, all other implants showed occasional multinucleated giant cells and a decrease in the cellular character of Zone #1. Both zones were reduced in thickness and composed of more mature fibroblasts. Some specimens exhibited intracytoplasmic vacuolization. It may be concluded, therefore, that surface-free energy of the implanted specimens played a significant role in inducing differential tissue response to otherwise similar pure metal samples.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 843-851 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Conventional finishing and polishing techniques used to prepare Vitallium subperiosteal dental implant castings were found to produce low energy surfaces as measured by critical surface tension. Standard metallographic preparation gave slightly higher values. Glow discharge cleaning of both types of polished surface gave much higher critical surface tension values. This suggests the presence of an organic film after surface polishing of the implant which may later affect tissue reaction, in particular attachment, as has been noticed in related animal studies.