Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 27 (2000), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The properties of denture base and reline resins may be affected by daily changes between room temperature and mouth temperature. The purpose of the study was to evaluate the effect of thermocycling on the flexural strength of the relined denture base polymer with reline resin. Three denture base resins, three hard reline resins and their combinations were tested. Fourteen specimens, 65×10×2·5 mm, were fabricated for each material. Polymer combination specimens were made using 1·5 mm hard reline resin on 1·0 mm cured denture base resins. Half of the specimens were stored for 50±2 h in distilled water at 37 °C, while the other half were thermocycled for 20 000 cycles between 4 and 60 °C. Three point bending tests were conducted on a universal testing machine at a cross-head speed of 0·5 cm/s. The flexural strengths were measured and a statistical analysis was performed on the data using three-way anova (P〈0·05). The results showed that the flexural strength of relined denture base polymer was significantly higher than that of hard reline polymer. Thermocycling did not affect the flexural strength of the relined denture base polymers, whereas the denture base polymer and reline polymer alone showed a decrease in strength after thermocycling.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 26 (1999), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of this study was to evaluate the influence of the lining design of a soft denture liner on its cushioning effect, using a free drop test and an accelerometer. The peak instantaneous acceleration value was computed. The materials tested were SuperSoft® (SS), Kurepeet-Dough® (KD), and Molloplast-B® (MB). Soft denture liners 2 mm in thickness were placed in test denture bases using three different configurations. Specimens were tested at 24 h and at 180 days after storage in distilled water at 37 °C. A three-way anova was used to analyse the data (P=0·05) and Tukey intervals were computed. It was found that all three materials were effective in reducing the impact force. The lining design that had the soft denture liner extended to the periphery of the denture base demonstrated the greatest shock absorbability of all the tested designs. A silicone denture liner using lining design 1 was the most effective in reducing the shock transmitted to the denture bases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...