Abstract Krypton-81m equilibrium ventriculography was used to study right ventricular function in 23 healthy male volunteers. Technetium-99m lung perfusion scintigraphy was employed to subtract radionuclide activity within lung during image analysis thereby enhancing image quality. The imaging technique was used to generate a time-activity curve for the right ventricle allowing the definition of indices of normal systolic and diastolic function for the right ventricle. At rest, indices of systolic ejection and diastolic filling were comparable to those previously reported for the left ventricle. Using this imaging technique, movement artifact during exercise reduces image quality and limits accurate measurement of these indices to resting studies.