Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1041
    Keywords: myasthenia gravis ; neostigmine ; gas chromatography-mass spectrometry ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary To permit rational evaluation of the empirical pharmacotherapy of myasthenia with cholinesterase inhibitors, a sensitive and selective method for the determination of neostigmine has been developed. Analysis is based on ion-pair extraction of neostigmine into methylene chloride and determination by gas chromatography-mass spectrometry (chemical ionization). As neostigmine was found to be metabolized in plasma in vitro, deuterated (d6) neostigmine was immediately added to the plasma sample as the internal standard. The limit of quantitation of the method was about 1 ng/ml (∼ 3nmol/l). The kinetics following i. v. administration were studied in four patients, who received neostigmine 2.5–3.0 mg iv to antagonize pancurone administered during anaesthesia. Elimination was rapid with a half-life t1/2 (β-slope) of 0.89±0.05 h (mean ± SE). The volume of distribution was 1.08±0.11 l/kg and plasma clearance was 0.84±0.04 l/kg/h. In three fasting myasthenic patients plasma concentrations of neostigmine were followed for 5 h after a single oral dose of 30 mg. Considerable interindividual differences in absorption were expressed in the peak concentrations, which occurred 1–2 h following drug ingestion. The bioavailability of neostigmine was estimated to be 1–2% of the ingested dose. Neostigmine concentration in plasma was found to differ considerably (up to forty-fold) between myasthenic patients on their ordinary dose-schedules of cholinesterase inhibitors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 18 (1980), S. 423-428 
    ISSN: 1432-1041
    Keywords: pyridostigmine ; myasthenia gravis ; pharmacokinetics ; bioavailability ; plasma levels
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of pyridostigmine was evaluated after intravenous injection in two healthy male volunteers and after oral administration to five subjects. Plasma concentrations of pyridostigmine were determined after ion pair extraction from plasma and analysis by gas chromatography — mass spectrometry with chemical ionization, using d6-pyridostigmine as internal standard. Degradation of pyridostigmine in vitro was compensated for by use of the deuterated internal standard and by rapid cooling and separation of plasma after blood sampling. After intravenous administration of pyridostigmine 2.5 mg the plasma elimination half-life was 1.52 h, the volume of distribution was 1.43 l/kg and the plasma clearance 0.65 l/kg × h. The pharmacokinetic constants were very similar after oral administration of pyridostigmine 120 mg; the elimination half-life was 1.78±0.24 h, the volume of distribution 1.64±0.29 l/kg and the plasma clearance was 0.66±0.22 l/kg × h. The bioavailability was calculated to be 7.6±2.4%. When pyridostigmine was taken together with food, the time to reach the peak plasma concentration was prolonged from 1.7 to 3.2 h. Bioavailability, however, was not influenced by concomitant food intake. “Steady-state” plasma concentrations of pyridostigmine were measured in myasthenic patients on their ordinary dose schedule of cholinesterase inhibitor drugs. More than a seven-fold difference in steady-state plasma concentration was found between patients taking approximately the same daily dose of pyridostigmine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Social Science Research 22 (1993), S. 115-130 
    ISSN: 0049-089X
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Sociology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Nuclear Instruments and Methods 89 (1970), S. 65-67 
    ISSN: 0029-554X
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Nuclear Instruments and Methods 72 (1969), S. 226-228 
    ISSN: 0029-554X
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Nuclear Physics, Section A 187 (1972), S. 426-432 
    ISSN: 0375-9474
    Keywords: Nuclear reactions ; fission
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    International journal of biometeorology 25 (1981), S. 39-45 
    ISSN: 1432-1254
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geography , Physics
    Notes: Abstract A weekly periodicity in the occurrence of headache was found in 53 patients with migraine and in 20 with tension headache during an observation period of four weeks. In the migraine group the frequency was highest on Thursday and on Saturday and lowest on Sunday–Monday, and in patients with tension headache it was lowest on Sunday–Tuesday and highest on Friday. During the observation period several climatic factors were recorded. After correction for the weekly periodicity a highly significant correlation was found in the migraine group between headache frequency, on the one hand, and atmospheric pressure and outdoor temperature recorded 1–3 days later, on the other.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-1459
    Keywords: Plasma exchange ; Guillain-Barré syndrome ; Auto-antibodies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 18 Patienten mit Guillain-Barré Syndrom, die einem therapeutischen Plasmaaustausch (PA) unterzogen wurden, wurde das Serum mit Hilfe einer gemischten Hämagglutinations-Technik auf IgG-Antikörper (IgG-AK) gegen peripheres Nervengewebe untersucht. Einfluß der PA auf den klinischen Zustand und Titerverlauf wurden verglichen: Bei 11 Patienten wurden IgG-AK gefunden; sie zeigten unter der PA′ eine klinisch verifizierte Besserung, die in einigen Fällen auch elektromyographisch gesichert werden konnte; nach Beendigung der PA waren nur noch in 2 Fällen IgG-AK nach-weisbar. Bei den restlichen 7 Patienten fehlten IgG-AK; bei ihnen war die PA ohne Effekt.
    Notes: Summary The mixed haemagglutination technique was used to demonstrate IgG antibodies to peripheral nerve tissue in sera from patients with the Guillain-Barré syndrome. The clinical effect and the effect on the antibodies of plasma exchange were examined in 18 patients. Neurological examination with muscle testing and neurophysiological examination of the patients were performed before and immediately after plasma exchange. Before the exchange antibodies were detected in sera from 11 of the patients. These patients showed clinical improvement during the treatment. After plasma exchange, antibodies were detected in sera from only two of the patients. The seven patients without detectable antibodies showed no clinical improvement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-1459
    Keywords: Guillain-Barré syndrome ; Plasma exchange ; Nerve antibodies ; Mixed haemagglutination test ; Complement fixation test
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Mixed haemagglutination and complement fixation tests were used to detect serum antibodies to peripheral nerve in 36 patients with acute Guillain-Barré syndrome. Twenty patients were treated with plasma exchange, 16 served as controls. A significant antibody titre was found in 19 patients with the haemagglutination test; 30 had complement-fixing antibodies. Patients lacking complement-fixing antibodies were less disabled at entry (P〈0.01). However, there was no correlation between the course of the disease and any of the antibodies in the two patient groups. The two tests were therefore not able to select patients for treatment by plasma exchange.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 247 (1971), S. 153-160 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The superconducting conversion electron analyser SULEIKA has been used to measure the electron spectrum of196Pt after neutron capture in195Pt. The experimental arrangement is described. Energies and intensities of 20K-, 10L- and 3M-lines are reported and, using known γ-data as well asK toL ratios, multipolarities are determined.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...