Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1041
    Keywords: salbutamol ; asthma ; beta-adrenoceptor ; controlled release formulation ; adverse effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The purpose of the present study was to compare the efficacy and systemic effects of 4 mg and 8 mg doses of salbutamol controlled release (SCR) after single dosing and at steady state in patients with asthma. Fifteen asthmatic patients (Age 36 y, FEV1 85% predicted) were given SCR 4 mg and 8 mg twice daily for 7 days in a randomised double-blind cross-over design, with at least 7 days washout between treatments. There were no differences between the bronchodilator effects of 4 mg and 8 mg doses. There was no evidence of tolerance to the bronchodilator effects after chronic dosing. Morning and evening PEFR measurements also showed improvements during treatment with SCR 4 mg and SCR 8 mg, although there were no differences between the two formulations. Both doses of SCR caused significant objective tremor responses which were maintained after chronic dosing. The 8 mg dose produced a larger tremor response after single dosing, but not at steady-state. Subjective tremor occurred in 7 patients with SCR 8 mg, and in 2 patients with SCR 4 mg. There were no cardiac arrhythmias on Holter ECG monitoring. These results suggest that the 8 mg dose of SCR was no more effective than the 4 mg formulation, and was associated with more systemic adverse effects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: salbutamol ; asthma ; controlled-release formulation ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Fifteen patients with asthma were given salbutamol controlled-release (SCR) 4 mg or 8 mg twice daily for seven days, in a randomised double-blind cross-over design. Plasma salbutamol levels were measured after the first and fifteenth doses for a 12 h period following drug ingestion. At steady-state the geometric mean values for Cmax were 8.2 ng/ml for 4 mg, and 16.1 ng/ml for 8 mg. Median tmax values were 300 and 240 min respectively. The geometric mean AUC (0–12) were 4507 ng·min·ml−1 and 8980 ng·min/ml. Peak to trough fluctuation ratios were 0.577 and 0.572. There were no significant differences between 4 mg or 8 mg formulations, for any of the parameters measured, after appropriate corrections for dose. The concentration-time profiles at steady-state showed little fluctuation in plasma salbutamol levels over the twelve hour dosing interval. These results show that 4 mg and 8 mg formulations of SCR provide smooth plasma profiles at steady-state with a twice daily dosing regime.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We investigated acute bronchoconstriction and changes in airway responsiveness to methacholine following the inhalation of platelet activating factor (PAF) in an open study of 12 non-asthmatic subjects. Ventilatory function was monitored using a flow rate at 30% of vital capacity (V̇30) and airway responsiveness was measured as PD40V̇30, i.e. the dose of metacholine causing a 40% fall in V̇30. PAF (3–422 μg) resulted in dose-related acute bronchoconstriction in 10 of the 12 subjects. There was no association between the airway responsiveness to PAF and to methacholine. Ten subjects showed some increase in airway responsiveness to methacholine 1 or 3 days following PAF. Overall, these changes were statistically significant (P 〈 0·05) but were of small magnitude (geometric mean PD40V̇30 pre-PAF=457 μg; 24 hr after PAF = 259 μg; 72 hr after PAF =258 μg) and variable: only seven subjects showing increased airway responsiveness on both day 1 and day 3 after PAF. Six subjects who appeared to show increases in airway responsiveness following PAF were re-studied with the inhaled PAF pre-medicated by either placebo or a specific thromboxane receptor antagonist (GR32191B) in a double-blind fashion. GR32191B did not reduce the acute bronchoconstriction due to PAF. In this part of the study, these six subjects did not show significant increases in airway responsiveness following the placebo pre-medicated PAF challenge and so no effect of the drug on airway responsiveness could be shown. We conclude that PAF-induced bronchoconstriction in normal individuals is not mediated by thromboxane and that any increases in airway responsiveness following PAF are frequently poorly sustained, are poorly reproducible, and are not readily detectable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...