Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 50 (1994), S. 290-292 
    ISSN: 1399-0047
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: High-resolution single crystals of a catalytic RNA molecule derived from the sequence of the satellite RNA of tobacco ringspot virus have been obtained. The unit-cell volumes of the RNA crystals vary depending on the crystallization conditions and temperature. The best crystal form, when flash frozen, has space group P1 with unit-cell dimensions a = 53.08, b = 71.81, c = 28.03 Å, α = 98.43, β = 104.32 and γ = 74.54°. This form diffracts to a resolution of 2.4 Å. A heavy-atom derivative search is in progress.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 60 (2005), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: This paper reviews published studies (identified by a Medline-assisted search) on the effect of ≤ 0.2 minimum alveolar concentration inhaled anaesthetic agents on the hypercapnic ventilatory response in healthy subjects. Each article was examined for the anaesthetic agent used, whether CO2 was administered using a rebreathing or a steady state (step hypercapnia) technique, and subject arousal (by audiovisual stimulation or by pain). Analysis of variance was used to assess the influence of each of these factors on the standardised hypercapnic response (the hypercapnic ventilatory response in l.min−1.kPa−1 in the presence of anaesthetic, expressed as a fraction of the response without anaesthetic). There were 21 separate studies embedded within 14 published articles. When considered together, the effect of anaesthetics on the hypercapnic ventilatory response was not significant (p = 0.089). Furthermore, when each agent was considered separately, no agent alone had a significant effect on the hypercapnic response. Neither subject arousal (p = 0.396) nor the method used to induce hypercapnia (p = 0.625) had any significant influence on the response. This suggests that the hypercapnic response is more resistant to the effects of anaesthetics than the hypoxic ventilatory response. These results indicate areas for future work. It would seem important to identify the cellular mechanisms which might underlie the difference in hypercapnic and hypoxic responses, and possible ways in which subject arousal might interact in the brain with the chemoreflexes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science, Ltd
    Anaesthesia 57 (2002), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary We assessed whether flexible fibreoptic-guided orotracheal intubation could be rapidly and successfully achieved during a simulated rapid sequence induction in 30 anaesthetised and paralysed patients. Rapid sequence induction was simulated by applying practised cricoid pressure. Using a␣flexible fibreoptic laryngoscope with camera and closed circuit television, an anaesthetist experienced with the technique performed orotracheal endoscopy and intubation with a cuffed 7.0-mm Portex tracheal tube through a VBM Bronchoscope Airway. Fibreoptic intubation was successful at the first attempt in 28 patients (93%); two patients required two attempts. Mean (SD) time from removal of the facemask from the patient's face to the appearance of carbon dioxide in the expired breath after intubation was 111 (46) s (median 100 s; range 54–195 s). There were one or more difficulties in 13 patients (43%). These difficulties were largely avoidable and included problems with fibreoptic equipment, the Bronchoscope Airway, copious secretions, cricoid pressure or railroading of the tracheal tube. Flexible fibreoptic-guided orotracheal intubation may have a place in the management of failed intubation during a rapid sequence induction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 57 (2002), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A patient in a permanent vegetative state required general anaesthesia for dental surgery. Because of the uncertainties involved in the appropriate monitoring and assessment of the conscious level of patients in a permanent vegetative state, it was decided to use the bispectral index to help guide the anaesthetic depth during surgery. We found that the bispectral index profile during anaesthesia and surgery was similar to that of a normal subject. The findings raise the possibility that patients in permanent vegetative states might sense noxious stimuli at a cortical level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary We conducted a two-part study to assess the practice of withholding neuromuscular blockade until the ability to ventilate the lungs using a bag and face mask (mask ventilation) has been established following induction of anaesthesia. The first part of the study consisted of a postal survey (71% response rate) of 188 anaesthetists in the Oxford region to assess their current practice. Thirty per cent of respondents always checked mask ventilation before administering a neuromuscular blocking drug, whereas 39% of respondents (all them consultants) never did this. A further 31% only did so in the case of known or anticipated difficulty with the airway. In the second part of the study, we measured inspired (VTI) and expired (VTE) tidal volumes before and after neuromuscular blockade in 30 patients undergoing general anaesthesia. The ratio VTE/VTI was used as a measure of the efficiency of ventilation. There was no difference in VTE/VTI before [mean (SD) 0.47 (0.13)] and after [0.45 (0.13)] neuromuscular blockade. We conclude that neuromuscular blockade does not affect the efficiency of mask ventilation in patients with normal airways.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We studied the success rates for tracheal intubation in 64 healthy patients during simulated grade III laryngoscopy after induction of anaesthesia, using either the single-use bougie or oral flexible intubating fibrescope, both in conjunction with conventional Macintosh laryngoscopy. Patients were randomly allocated to either simulated grade IIIa or grade IIIb laryngoscopy, and also to one of the two study devices. Success rates for tracheal intubation (primary outcome measure) and times taken to achieve intubation (secondary outcome measure) were recorded. For the simulated grade IIIa laryngoscopy group, the fibreoptic scope was more successful than the bougie (16/16 successful intubations vs. 8/16; p = 0.02). For the simulated grade IIIb laryngoscopy group, the fibreoptic scope was also more successful than the bougie (8/16 successful intubations vs. 1/16; p = 0.02), but clearly use of the fibreoptic scope was not as successful as it had been in simulated grade IIIa laryngoscopy (p = 0.04). With either device, median (range) total tracheal intubation times for successful attempts with either grade of laryngoscopy were less than 60 s (19–109) and there were no clinically important differences. We conclude that the fibrescope used in conjunction with Macintosh laryngoscopy is a more reliable method of tracheal intubation than the single-use bougie in both types of grade III laryngoscopy. This finding has implications for the management of patients in whom grade III laryngoscopy is encountered unexpectedly after induction of anaesthesia, and also for the management of patients previously known to have grade III view at laryngoscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 57 (2002), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary The purpose of this study was to review published studies (identified by a Medline-assisted search) on the effect of  ? 0.2 minimal alveolar concentration (MAC) halothane, isoflurane, enflurane and sevoflurane on the acute hypoxic ventilatory response in healthy subjects. Each article was examined for the anaesthetic agent, speed of hypoxic stimulus, background carbon dioxide and subject stimulation (audiovisual or painful). Analysis of variance was used to assess the significance of the influence of each of these factors on the standardised hypoxic response (the acute hypoxic ventilatory response in l.min−1 in the presence of anaesthetic, expressed as a fraction of the response without anaesthetic). There were 37 separate studies within 21 published articles. The main factor influencing standardised hypoxic response was anaesthetic agent (p 〈 0.002). A second influential factor was subject stimulation (p 〈 0.014), but the interaction term of agent and stimulation was also significant (p 〈 0.039), suggesting that the influence of stimulation varied with the agent used. Speed of hypoxia and background carbon dioxide had no influence. In contrast to previous authors' assertions that study conditions have a major impact on the acute ventilatory response to hypoxia, this review suggests that the main determinant is simply the anaesthetic agent used. The review also highlights important gaps in the research literature, which may direct future research in this field. In particular, it would seem important to investigate the influence of arousal when different anaesthetic agents are used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 56 (2001), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary We studied the success rates for tracheal intubation in 32 healthy, anaesthetised patients during simulated grade IIIa laryngoscopy, randomised to either the multiple-use or the single-use bougie. Success rates (primary end-point) and times taken (secondary end-point) to achieve tracheal intubation were recorded. The multiple-use bougie was more successful than the single-use one (15/16 successful intubations vs. 9/16; p = 0.03). With either device, median [range] total tracheal intubation times for successful attempts were 〈 54 [24–84] s and there were no clinically important differences between these times. We conclude that the multiple-use bougie is a more reliable aid to tracheal intubation than the single-use introducer in grade IIIa laryngoscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary We compared the times to intubate the trachea using three techniques in 60 healthy patients with normal airways: (i) fibreoptic intubation with a 6.0-mm reinforced tracheal tube through a standard laryngeal mask airway (laryngeal mask−fibreoptic group); (ii) fibreoptic intubation with a dedicated 7.0-mm silicone tracheal tube through the intubating laryngeal mask airway (intubating laryngeal mask−fibreoptic group); (iii) blind intubation with the dedicated 7.0-mm silicone tracheal tube through the intubating laryngeal mask airway (intubating laryngeal mask−blind group). Mean (SD) total intubation times were significantly shorter in the intubating laryngeal mask−blind group (49 (20) s) than in either of the other two groups (intubating laryngeal mask−fibreoptic 74 (21) s; laryngeal mask−fibreoptic group 75 (36) s; p 〈 0.001). However, intubation at the first attempt was less successful with the intubating laryngeal mask−blind technique (15/20 (75%)) than in the other two groups (intubating laryngeal mask−fibreoptic 19/20 (95%) and laryngeal mask−fibreoptic 16/20 (80%)) although these differences were not statistically significant. We conclude that in this patient group, all three techniques yield acceptable results. If there is a choice of techniques available, the intubating laryngeal mask−blind technique would result in the shortest intubation time.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...