This study is concerned with developing laminar flow of an incompressible, Newtonian fluid, having constant viscosity, rotating in circular and rectangular ducts that contain a 180° bend. The Reynolds number ranges from 100 to 400, the rotation number from 0 to 0.4, and the Dean number from 66 to 264. Positive and negative rotation modes are considered. The artificial compressibility method is used for the numerical calculations and new boundary conditions are developed for these flows. It is shown that rotation causes the secondary flow to occur in ducts of any geometry, and that the strength of the secondary flow in the bend due to both rotation and curvature decreases as compared to the no rotation case.