Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Molecular absorption spectrometry ; Gas phase detection ; Benzene derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple and inexpensive detection system for gas chromatography, based on gas-phase, molecular absorption measurements, is presented in which the chromatographic column is directly joined to the spectrophotometer flow cell, without heated transfer lines. A mixture of eight benzene compounds (including methyl, halogen and nitrogen derivatives) were separated and analyzed. Parameters affecting separation (temperature program and carrier gas flow) and measurement quality (wavelength and integration time) were studied and a measurement program designed to modify the wavelength during chromatography. The analytical characteristics of each compound were calculated, obtaining detection limits ranging from 0.5 to 9 μg mL−1. Finally, the method was applied to several synthetic mixtures, with good results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 355 (1996), S. 733-735 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A hyphenated technique for coupling a spectrophotometric detector to a gas chromatograph with a packed column is described. The packed column was connected directly to the flow cell (path length 1 cm) which was placed in a UV-visible molecular absorption spectrophotometer with diode array detector. This detection system was employed for separating and determining benzene, toluene, 1,4-xylene, 1,2-xylene and mesitylene. Molecular absorption spectra of all the separated compounds have also been obtained. A new possibility for coupling capillary gas chromatography and gas phase molecular absorption spectrometry is currently being tested. In this new case, two fibre optics are used and the measurement is performed in the capillary column.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...