Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 226 (1970), S. 554-555 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The longevity of squeeze films has never been studied in whole joints. Experiments have been carried out in either glass?glass3,6 or cartilage?glass7 interfaces. We have studied the possible role of the hydrostatic mechanism in joint function, using the sagittal halves of bovine ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 222 (1969), S. 999-1000 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Plugs of apparently normal articular cartilage from the phalangeal surface of the metatarsal-phalangeal joints of freshly slaughtered adult cows, aged 3-5 yr, were obtained with a cork borer. The diameter of all plugs was 0-24 inches. The plugs' height varied from 0-020 to 0-030 inches, measured ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International orthopaedics 11 (1987), S. 255-259 
    ISSN: 1432-5195
    Keywords: Low back pain ; Spondylosis ; Disc excision ; Intervertebral facet syndrome ; Ruptured intervertebral disc
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Cette étude concerne 247 patients qui continuaient à souffrir six mois à deux ans après ablation d'une hernie discale. Plus de la moitié d'entre eux présentaient une arthrose des articulations intervertébrales postérieures L5-S1, habituellement associée à une obliquité du bassin. D'autres causes organiques furent mises en évidence chez 18% des patients. L'échec n'était dû à une cause inorganique que dans 13% des cas. Plus de 70% des patients présentant une arthrose des articulaires postérieures furent améliorés par le traitement de cette affection.
    Notes: Summary This study reviews 247 patients who still had preoperative complaints six months to two years after disc excision. In over half, spondylosis of the L5-S1 facets was present, concurrently associated with a pelvic obliquity. A number of other organic causitive factors were identified in 18% of the patients. Nonorganic reasons accounted for failure in only 13%. Over 70% of patients with associated spondylosis were improved by treatment directed at this condition.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 7 (1973), S. 401-418 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Scanning electron micrographs were made of the surfaces of silicone rubber finger joint prostheses which had been subjected to 107 bending cycles at 37°C in bovine serum. Preferential attack at the regions of highest stress and the formation of microcracks of length 10μ and less were observed. By way of analogy with the corrosion fatigue phenomenon in metallic alloys, it is suggested that these may be initiation sites for the mechanical failures which have been observed, and that the acceleration of lipid absorption by tensile stress provides potential mechanisms for both initiation and accelerated propagation of fatigue cracks. It is demonstrated as a consequence of mechanochemical thermodynamics that any constituent of the body fluids (e.g. lipids) which can swell the elastomer will in fact be preferentially absorbed at the point of highest tensile stress, i.e., the crack tip, and that swelling will be accelerated by the applications of tensile stress.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 10 (1976), S. 605-611 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Total joint and other prostheses often require the removal and replacement of considerable quantities of cancellous bone, and often are anchored in place by grouting into cancellous bone. Thus, a possible source of failure or loosening of many types of prostheses may be rooted in the lack of understanding of the structure, properties, and function of this material. In addition, as we have pointed out before, cancellous bone may play an important biomechanical role in the etiology of joint degeneration. With these considerations in mind, the architecture of the cancellous bone in the human patella was studied by serial sectioning and microradiography, using an improved technique developed in our laboratory. Volumes of cancellous bone with apparently different functional roles were identified. Stereological techniques were used to quantify the structural characteristics and geometrical relationships throughout the patella. These results led to a structural model for the cancellous bone of the patella, and a comprehensive picture of the internal architecture.The distribution of mechanical compliance and yield stress was also measured, as a function of location and orientation, by a specially constructed micro-compression testing machine. The measurements reflected the distribution of trabecular architecture, and both the properties and architecture reflected the gross biomechanical function of the patella. Furthermore, a true structure-function relationship was derived. Patellar contact area studies were performed on fresh cadavers and mapped for various angles of flexion. The variation in contact areas and the spatial variations in stiffness are discussed relative to the biomechanics and clinical aspects of the patella.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 6 (1988), S. 475-492 
    ISSN: 0736-0266
    Keywords: Synovium ; Articular cartilage ; Osteoarthrosis ; Hulth model ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The Hulth instability model was performed on 25 rabbit knee joints. Electron-microscopic, light-microscopic, and histomorphometric data demonstrated consistent chondrocyte alterations and cartilage destruction. The comparison between operated, sham, and control knees shows that surgical intervention without surgically induced instability is followed by changes in the synovial membrane and cartilage. The cartilage destruction is preceded by a synovial reaction, suggesting that the inflammatory response has an important role in the onset of cartilage damage in this model. The damage was more severe in the experimental knees, suggesting that mechanical instability is also a factor in cartilge destruction.
    Additional Material: 17 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...