Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street, Malden, MA 02148, USA. : Blackwell Futura Publishing, Inc.
    Journal of interventional cardiology 16 (2003), S. 0 
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Interventional occlusion of pulmonary arteriovenous malformations with large feeding arteries may be associated with an increased risk of device embolization. In a 40-year-old patient with a solitary pulmonary arteriovenous malformation one large feeding artery was successfully closed by means of an Amplatzer septal occluder and detachable coils. The use of an Amplatzer septal occluder should be considered as an alternative therapeutic option in cases of huge pulmonary arteriovenous malformation to reduce the risk of device embolization. (J Interven Cardiol 2003;16:335–339)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of interventional cardiology 14 (2001), S. 0 
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Four different types of occluder systems were used to close a persistent foramen ovale (PFO) in 162 patients with paradoxical embolic events. Ninety-eight patients had ischemic stroke, 60 transient ischemic attacks (TIA) or prolonged reversible ischemic neurological deficit (PRIND), and 4 had peripheral arterial embolism. The age of the patients was 40.2 ± 11.9 years and the ischemic event had happened 7 ± 10 months before device closure. CardioSeal and Amplatzer occluders were the most commonly used devices (73 and 77 cases, respectively). Implantations were successful in all patients. Serious catheter-related complications included two device embolizations and two venous bleedings. Six patients had documented supraventricular arrhythmias within the first month after implantation, which disappeared spontaneously within some weeks without therapy in three patients; the other three patients with atrial fibrillation needed conversion to sinus rhythm. Residual leaks were found in 5 out of 116 patients who had been followed by transesophageal echocardiography (TEE) and one leak was closed by a second device. During a follow-up period of 19.4 ± 16.2 months per patient, TIA and PRIND occurred in 3 of 116 patients. Interventional closure of PFO is a simple, effective and quick method that is superior to surgery and avoids the problems of life-long anticoagulation. (J Interven Cardiol 2001;14:223–230)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...