Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 55 (1983), S. 116-119 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 10 (1983), S. 369-376 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The simultaneous acquisition of both positive ion and negative ion data under chemical ionization mass spectrometric conditions can aid in the confirmation of assignments made by electron impact gas chromatography mass spectrometry or electron capture gas chromatography. Pulsed positive ion negative ion chemical ionization mass spectrometry coupled with fused-silica capillary column gas chromatographic methods is shown to be useful in environmental and hazardous waste sample analysis. The chemical ionization conditions which maximize sensitivity and the amount of molecular ion information for the priority pollutants are presented. Replicates of response factors for these compounds show good precision. Saturation is observed about 10 ng for those pesticides which give linear responses from 50 pg to 1-10 ng.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 27-30 
    ISSN: 0935-6304
    Keywords: Gas chromatography/mass spectrometry ; Capillary columns, fused silica ; Response factors, interlaboratory ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A quality control procedure for Fused Silica Capillary Column Gas Chromatography/Mass Spectroscopy (FSCC GC/MS) was tested and shown to produce similar response factors at five Spectroscopy (FSCC GC/MS) was tested and shown to produce similar response factors at five laboratories. The average relative standard deviation (RSD) of interlaboratory response factors for fifty three compounds of environmental interest determined at each laboratory at nominal injected weights of 20, 100, and 200 ng was found to be 18.9% for four of the five laboratories which participated in this work. These data demonstrate that similar response factors can be attained in routine GC/MS measurements when adequate quality control is maintained.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 366-384 
    ISSN: 0935-6304
    Keywords: GC/MS ; Capillary columns, fused silica ; Priority pollutants ; Quantitation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Operational characteristics have been determined for fused silica capillary column (FSCC) GC/MS as applied to “extractable” priority polutants. Chromatographic data show excellent relative retention time (RRT) intralaboratory precision and interlaboratory accuracy when multiple internal standards are empolyed. Potential chromatographic problems, such as column overload and “double peaking”, are addressed. Response factor relative standard deviations (RSD) at 50 ng for most of the extractable priority pollutants over the long term indicated precise determination (i.e. RSD generally ≤ 10%). Linearity was demonstrated over two orders of magnitude for FSCC GC/MS analysis of compounds with relatively low and high RF (response factor) values. Potential quantitative problems, such as saturation, are discussed. For certain aromatic priority pollutants interlaboratory RF agreement was observed. This was noted as perhaps the most important property of FSCC GC/MS analysis when the multiple internal standard approach is utilized. Determinations of extractable priority pollutants are directly compared for paced column GC/MS and FSCC GC/MS analysis of separate and composited extracts. For six extracts analyzed in triplicate, the latter configuration was shown to produce more consistent results. In view of the superior analysis logistics of composite extract FSCC GC/MS analysis, this approach was established as the preferred method for the analysis of priority pollutants classified as extractable.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...