Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of industrial microbiology and biotechnology 19 (1997), S. 118-122 
    ISSN: 1476-5535
    Keywords: Keywords: CTC; activated sludge; bacterial activity; formazan; tetrazolium salt; waste water treatment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The tetrazolium salt 5-cyano-2,3-ditolyltetrazolium chloride (CTC) was used for the determination of metabolically active bacteria in active sludge. The method was adapted and optimized to the conditions of activated sludge. The colorless and nonfluorescent tetrazolium salt is readily reduced to a water-insoluble fluorescent formazan product via the microbial electron transport system and indicates mainly dehydrogenase activity. After more than 2 h incubation, no further formation of new formazan crystals was observed, although the existing crystals in active cells continued to grow at the optimal CTC-concentration of 4 mM. The dehydrogenase activity determined by direct epifluorescence microscopic enumeration did not correlate with cumulative measured activity as determined by formazan extraction. The addition of nutrients did not lead to an increase of CTC-active cells. Sample storage conditions such as low temperature or aeration resulted in a significant decrease in dehydrogenase activity within 30 min. The rapid and sensitive method is well suited for the detection and enumeration of metabolically active microorganisms in activated sludge. Extracellular redox activity was measured with the tetrazolium salt 3′-{1-[phenylamino-) carbonyl]-3,4-tetrazolium}-bis(4-methoxy-6-nitro)benzene-sulfonic acid hydrate (XTT), which remains soluble in its reduced state, after extraction of extracellular polymeric substances (EPS) with a cation exchange resin.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 45 (1994), S. 29-39 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Microbial deterioration of materials - biofilm and biofouling: BiofoulingThe undesired deposition of microorganisms and the formation of biofilms is called “biofouling”. In water systems, biofilms are contamination sources for the water phase and support rapid microbial regrowth. Biofilms cover surfaces. In membrane processes, this leads to an increase of the hydraulic membrane resistance. Biofilms are viscoelastic and display a more or less rough surface. Thus, they consume kinetic energy and cause an increased pressure drop when water is pumped. In porous filter media, membrane systems, heat exchangers, water pipelines and on ship bottoms, thus, the energy demand is increased while the performance is decreased. In heat exchangers, biofilms represent a gel layer between medium and surface. This allows only diffusive but no convective heat transport and, thus, decreases the effectivity of the heat transfer process. The loss of performance and product quality as well as by cleaning efforts due to biofouling causes high technical and financial damage. This is increased indirectly by counter-measures such as the application of biocides, because these may promote corrosion processes and contaminate the environment.
    Notes: Die unerwünschte Ablagerung von Mikroorganismen und die Bildung von Biofilmen wird als Biofouling bezeichnet. In Wassersystemen führen Biofilme zur Kontamination der Wasserphase und zu verstärkter Wiederverkeimung. Außerdem werden Oberflächen abgedeckt. Bei Membranprozessen führt dies zu einem erhöhten Permeationswiderstand. Biofilme sind viscoelastisch und haben eine mehr oder weniger rauhe, verformbare Oberfläche. Dadurch verbrauchen sie kinetische Energie und führen zu einem erhöhten Druckabfall, wenn Wasser gepumpt wird. In porösen Filtermaterialien, Membransystemen, Wärmetauschern, Wasserleitungen und auf Schiffsböden führt dieser Effekt zu einem erhöhten Energiebedarf bzw. zur Leistungsverminderung. Bei Wärmetauschern verschlechtern sie zudem den Wärmeübergang, weil sie eine Gel-Schicht zwischen Medium und Austauscherfläche bilden, in der nur diffusiver, aber kein konvektiver Wärmeübergang möglich ist. Durch verringerte Anlagenleistung, verringerte Produktqualität und erhöhten Reinigungsaufwand entstehen große Schäden. Indirekt werden sic durch Gegenmaßnahmen wie den Einsatz von Bioziden vergrößert, wel diese u. U. Korrosionsprozesse fördern und häufig umweltbelastend wirken.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 45 (1994), S. 40-53 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Microbial deterioration of materials - biofilm und biofouling: Countermeasures against biofouling in water systemsCountermeasures against biofouling include three steps: i) detection, ii) sanitization and iii) prevention of biofouling. The detection has to refer to surfaces. Cell counts in water samples do not reflect site or extent of biofilms. Biocides display only limited value in terms of removal of biofouling layers. First, biofilm organisms are protected against biocides and tolerate 10-1000 fold higher concentrations. Second, water systems usually cannot be kept sterile. Thus, dead biofilms provide nutrients and suitable surfaces for further growth of cells imported with the raw water. Cleaning of a system is an integral part of sanitization and even more important than disinfection. It has to base on a designed strategy. Efficiency control is mandatory, which has to occur on representative surfaces. The prevention of biofouling is frequently achieved by continuously dosage of biocides. This is, however, only possible with suitable raw waters and many failures are reported. Chlorine is still the biocide most frequently used. Reasons of effectivity and environmental protection give rise to other strategies. “Good housekeeping” is recommended as countermeasure. It consists of frequent cleaning, efficiency control, biofilm monitoring, limitation of nutrients, maintenance of high shear forces and a cleaning-friendly design.
    Notes: Bei der Bekämpfung von Biofouling müssen drei Probleme gelöst werden: 1. der Nachweis, 2. die Beseitigung der Störung und 3. die Vermeidung zukünftiger Schäden. Der Nachweis von Biofouling muß durch Beprobung von Oberflächen erfolgen; Zellzahlen in Wasserproben lassen weder über Ort noch Ausmaß von Biofilmen eine Aussage zu. Für die Beseitigung von Biofilmen sind Biozide nur begrenzt geeignet. Zum einen werden Biofilm-Organismen durch die Schleimmatrix geschützt, so daß sich ihre Biozid-Toleranz um eine bis zwei Größenordnungen erhöhen kann. Zum anderen reicht die Abtötung nicht aus, weil technische Systeme nicht steril gehalten werden können. Tote Biomasse dient für Keime, die mit dem nachfolgenden Rohwasser eingetragen werden, als Aufwuchsfläche und Nährsubstrat. Daher ist die Reinigung des Systems eher noch wichtiger. Dafür ist eine gezielte Strategie notwendig. Sie muß von einer Erfolgskontrolle begleitet sein, die durch Inspektion repräsentativer Oberflächen geschehen muß. Die Verhinderung von Biofouling wird oft durch kontinuierliche Dosierung von Bioziden erreicht; dies ist allerdings nur bei geeigneten Rohwässern möglich, und es werden zahlreiche Mißerfolge berichtet. Für die Dauerdosierung wird vor allem Chlor eingesetzt, was allerdings aus Gründen der Wirksamkeit und des Umweltschutzes als unbefriedigend angesehen wird. “Technische Hygiene” wird als Gegenstrategie empfohlen. Sie besteht aus häufiger Reinigung, Erfolgskontrolle, Biofilm-Monitoring, Limitierung der Nährstoffe, Aufrechterhaltung hoher Scherkräfte und einem reinigungsfreundlichen Design der Anlage.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 45 (1994), S. 54-57 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Microbial deterioration of materials - biofilm and biofouling: Quantification of respiratory active bacteria in water and in biofilms by means of a fluorescent redox dyeThe question of physiological activity of microorganisms is in many microbially caused problems of strong interest. A method is presented which allows the direct quantification of respiratory active bacteria in water and biofilm samples. The determination is performed with a fluorescent redox dye (5-cyano-2,3-ditolyltetrazolium chloride [CTC]). By means of the fluorescence a very sensitive detection of reducing activity can be achieved, even on opaque surfaces. The activity of the biomass can be determined as well as the activity of single cells. The latter can be performed microscopically by determination of the light yield, because a readily detectible, fluorescent crystal is formed inside the cell by its reductive activity. The method is easy to carry out and takes only 1-2 h. It gives the number of physiologically active cells and can be combined with other methods, giving the total cell number. The CTC test is suitable for routine measurements as well as for monitoring. It is also useful to assess the effectivity of biocide application.
    Notes: Immer wieder taucht bei der Bearbeitung mikrobieller Probleme die Frage auf, ob die Mikroorganismen physiologisch aktiv sind oder nicht. Es wird eine Methode vorgestellt, die eine direkte Quantifizierung atmungsaktiver Bakterien in Wasser- und Biofilmproben zuläßt. Die Bestimmung wird mit einem fluoreszierenden Redoxfarbstoff (5-Cyano-2,3-Ditolyltetrazoliumchlorid [CTC]) durchgeführt. Durch die Fluoreszenz ist ein empfindlicher Nachweis sowohl im Wasser als auch auf undurchsichtigen Oberflächen möglich. Die Biomasse-Aktivität kann summarisch bestimmt werden, es läßt sich aber auch die Aktivität einzelner Zellen über die Lichtausbeute mikroskopisch feststellen, denn bei der Reaktion entsteht ein sehr gut detektierbarer fluoreszierender Formazan-Kristall. Das Verfahren ist einfach und in kurzer Zeit (1-2 h) durchzuführen. Es liefert die Anzahl physiologisch aktiver Zellen und kann mit Färbemethoden zur Ermittlung der Gesamtzellzahl kombiniert werden. Der CTC-Test bietet sich damit für Routineuntersuchungen und für die Eigenkontrolle an, nicht zuletzt, um die Wirksamkeit von keimtötenden Maßnahmen zu überprüfen.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...