Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Geophysical prospecting 49 (2001), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Notes: This paper describes J.G. Hagedoorn's work on ‘ultimate sailing’– the combination of a manned kite and a water kite called a Hapa, constituting a minimal sailing system – and the way others have taken up his challenge to sail while suspended from a kite. Hagedoorn's goal has not been entirely achieved, but ‘near’ and partial solutions have been reached. Kite-Hapa-sailing continues to pose a ‘Holy Grail’ type challenge to many kite-sailors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 36 (1925), S. 65-80 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Naturwissenschaften 42 (1955), S. 555-555 
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 121 (1943), S. 63-72 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Zusammenfassung Aus Messungen der Hyperfeinstruktur der Terme 5d 3 6s 2,4 F 3/2, 5/2, 9/2,4 P 3/2 des Ta I-Spektrums wird das Quadrupolmoment des 73 181 Ta-Kerns zu etwa +6·10−24 abgeschätzt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 39 (1975), S. 117-153 
    ISSN: 1573-2622
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Theoretically the contact lens with a refractive power of -64 dioptres is superior to the concave pre-set lens (Hruby lens) or the convex lens (Bayadi). In practice the results are as follows: With the convex lens the examination of the vitreous is unsatisfactory. The reversed image with the convex lens will become familiar with some experience as one will also get used to the mirror images of the three-mirror contact lens. However, the abnormal curvature of the image is really a nuisance. On the other hand the large field of view is an advantage. The convex lens is only practically useful when it can be firmly attached to the slit-lamp microscope, as otherwise the new adjustment necessary for searching the fundus is too difficult. Attachment to the microscope is also of advantage with the Hruby lens. The concave contact lens of 64 dioptres is best suited for detailed examination of vitreous and fundus and for measurements. When no value is placed on a minute examination and a quick simple orientation suffices, the concave pre-set lens (Hruby lens) has the advantage that the lens does not have to be placed on the eye. If it is centred to the middle axis of the microscope, it facilitates especially quick observation. There will be cases where the pre-set lens will be the only answer, especially shortly after an operation or with very sensitive patients. Furthermore, the Hruby lens is preferable to the Bayadi lens because the vitreous can be better examined. The Hruby lens is also advantageous for examination of the region in the middle, lateral periphery of the fundus, 30° – 60°, and is superior in this area to the simple concave contact lens. The Bayadi lens seems to us only indicated for fundus examination of extremely high myopes. There it definitely offers advantages over and above the concave lens. For the most peripheral fundus, expecially below and above, the three-mirror lens with its modification is so far the best method. Especially for examination of the vitreous good brightness of the slit image is required for stereoscopic examination with as large an angle as possible between microscope and illumination. The lateral parts of the most peripheral fundus cannot be examined with the vertical slit in connection with the three-mirror lens. However, this is possible with the horizontal and tilted position of the slit and intermediate positions with an oblique slit. The slit must form an angle with the microscope in order to examine vitreous and fundus in optical section. With the indentation contact lenses ciliary processes and pars plana are now accessible to slit-lamp microscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 19 (1965), S. 123-251 
    ISSN: 1573-2622
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Le coefficient de rigidité étant variable dans les différents procédés d'exploration de l'oeil glaucomateux, on est obligé d'en tenir compte dans chaque mensuration tonométrique, même lors de variations minimes de la tension. Ceci peut être évité par l'emploi de méthodes dont le résultat n'est pas influencé par le coefficient de rigidité. C'est par les travaux de Friedenwald qu'il a été possible d'évaluer le coefficient de rigidité et le P0 au moyen du tonomètre de Schiötz. Le tonomètre par aplanissement de Goldmann nous permet, en mesurant la valeur différentielle, de corriger non seulement la rigidité oculaire, mais encore les défauts instrumentaux du tonomètre de Schiötz, les fautes dues à une calibration inexacte de cet appareil et même l'influence des variations de la courbure cornéenne. Au moyen du tonomètre par aplanissement de Goldmann nous avons réussi à construire des schémas tension-volume pour les tonomètres par aplanissement. La mensuration de la rigidité oculaire et de la valeur-différentielle peut se faire aussi avec le tonomètre de Maklakoff, employé avec des colorants aqueux ou glycérines. Dans ces conditions le tonomètre de Schiötz et le tonomètre de Maklakoff, quoique basés sur des principes totalement différents, nous fournissent des résultats identiques.
    Abstract: Summary The findings of change of the coefficient of scieral rigidity under different diagnostic and therapeutic conditions, as they are particularly frequent in connection with glaucoma, necessitate either to take into consideration the rigidity coefficient in every single case even when small changes of pressure occur or to apply such methods, the results of which are not influenced by the rigidity. Friedenwald's work enables us to determine with the Schiötz-tonometer the rigidity coefficient and the P0-value, the Goldmann-Applanation-tonometer provides us with the differential-value-method to correct beside the rigidity also instrumental shortcomings and calibration inexactitudes of the Schiotz-tonometer and deviations of the mean value of corneal curvature. With the Goldmann-Applanation-tonometer it has been possible for us to design pressure-volume charts for Applanation-tonometer. Rigidity- and Differential-value-determination can be carried out with the Maklakoff-tonometer using aqueous or glycerine dyes. Thus the same results are obtained with the Schiötz and Maklakoff-tonometer, tonometers of entirely different principle which are most commonly used in the world.
    Notes: Zusammenfassung Die Befunde über die Änderung des Rigiditätskoeffizienten unter verschiedenen diagnostischen und therapeutischen Bedingungen, wie sie in der Augenheilkunde besonders im Zusammenhang mit dem Glaukom üblich sind, machen es notwendig, entweder in jedem einzelnen Fall, selbst bei kleineren Druckänderungen, den Rigiditätskoeffizienten im Rahmen der Tonometrie jeweils zu berücksichtigen, oder solche Methoden anzuwenden, bei denen der Rigiditätskoeffizient das Resultat nicht beeinflusst. Ist es seit den Arbeiten Friedenwalds möglich, mit dem Schiötz-Tonometer Rigiditätskoeffizient und P0-Wert zu bestimmen, so kann man mit Hilfe des Applanationstonometers nach Goldmann im Rahmen der Differenzwert-Bestimmung neben der Rigidität auch instrumenteile Mängel und Kalibrationsungenauigkeiten des Schiötz-Tonometers und Abweichungen des Hornhautradius vom Mittelwert korrigieren. Mit Hilfe des Applanationstonometers nach Goldmann war es uns ausserdem möglich, Druck-Volumen-Schemata für Applanationstonometer zu konstruierten. Nach Färbung sowohl mit wässerigen als auch Glycerinhaltigen Farbstoffen kann man Rigiditäts-oder Differenzwertbestimmungen auch mit dem Maklakoff-Tonometer durchführen. Man kommt so bei Verwendung von Schiötz- und Maklakoff-Tonometer Tonometern ganz verschiedenen Prinzips, die in der Welt am meisten gebraucht werden, zu gleichen Resultaten.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 153 (1926), S. 191-218 
    ISSN: 0863-1786
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Nach Neueren von W. BILTZ, G. F. HÜTTIG u. a. in eine experimentell-brauchbare Form gebrachten Methoden wurden die Zersetzungsdiagramme der Oxyden des Chroms festgelegt und ausgewertet. Die hauptsächlichen Ergebnisse sind die folgenden:1Die Zersetzung des Chromtrioxyds führt über zwei Zwischenoxyde der Zusammensetzung Cr5O13 und Cr5O12, von denen ersteres bisher nicht-bekannt war. Es konnte der Beweis geführt werden, daß diese Verbindungen Chromichromate darstellen, und ihre Zersetzung primär unter Abspaltung von Chromtrioxyd vor sich geht. Die übrigen, in der Literatur angeführten Oxyde des Chroms mit einem zwischen CrO3 und Cr2O3 liegenden Sauerstoffgehalt konnten bei der Zersetzung des Chromtrioxyds nicht erhalten werden.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 38 (1966), S. 250-254 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Bei der Optimierung nach unterschiedlichen wirtschaftlichen Gesichtspunkten ist die genaue Erfassung des Trends von Funktionen in einem einzugrenzenden Bereich von besonderer Bedeutung. Mit dem hier erläuterten Begriff der Progression ist dies für verschiedenartige Modellfunktionen in gleicher Weise möglich, wie an Beispielen aus der Verfahrenstechnik erläutert wird. Ausschlaggebend für wirtschaftliches Optimieren sind die Erfolgsfunktionen. Faßt man die unterschiedlichen, beim Optimieren von Anlagen zu berücksichtigenden Funktionen zusammen, so kann man mit Hilfe ihrer Progressionen und einer verbindlichen Bedingungsgleichung klären, ob überhaupt oder unter welchen Umständen bestimmte wirtschaftliche Forderungen erfüllbar sind.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 21 (1888), S. 1811-1812 
    ISSN: 0365-9496
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 42 (1909), S. 3856-3857 
    ISSN: 0365-9496
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...