Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 5556-5564 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A broadband coherent anti-Stokes Raman spectroscopy (CARS) system optimized for single shot measurements in turbulent flames is described. The CARS spectrometer incorporates an intensified photodiode array (IPDA) with a P46-phosphor based intensifier that is shown to have an order of magnitude less image persistence than P20-phosphor based IPDAs, and thus largely eliminates the temperature errors that can result from this image persistence. The low and high signal nonlinearity of IPDAs incorporating both P20 and P46 phosphor based intensifiers is described. The CARS signal is dispersed with a single element concave holographic diffraction grating, which is fiber-optically coupled. To provide the necessary dynamic range (approximately 1000:1) to handle CARS spectra whose temperatures can vary from 300 K to adiabatic flame temperatures a fiber-optic splitter was employed and the nonlinearity of the IPDA detectors was characterized. A method of determining the nonlinearity was developed that was convenient and the fiber-optic link was shown to provide a stable calibration of this nonlinearity. The problem of dye laser spectral drift, which is particularly severe in a long duration experiment, was addressed by constructing a compact high resolution spectrometer to continuously monitor the dye laser. The dye laser center frequency was maintained constant by manually adjusting an intracavity tuning filter. The accuracy of this technique and its effect on CARS derived temperatures was evaluated. The standard method of determining the instrument function by fitting to 295 K air spectra was compared to other methods and its use was shown to result in an uncertainty of less than 0.5% in CARS derived temperatures. The operation of this CARS instrument was demonstrated in a turbulent diffusion flame. The varying composition in these flames was accounted for by fitting C, the ratio of the nitrogen mole fraction to the total third order nonlinear susceptibility.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 171 (1970), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...