    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Pressure drop ; Retention ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effects of the pressure drop across the column on retention and efficiency in SFC have been studied. Numerical methods are described which enable the prediction of hold-up time and pressure drop in both packed and open tubular columns. Predictions of both hold-up time and pressure drop are in good agreement with experimental data.The density gradient along the column can be calculated using the numerical methods and a procedure is described which enables the calculation of the overall capacity factors of the solutes from the density profile in the column. Significant variations of the capacity factor are observed along the column.The effect of the density gradient along the column on local diffusivity and dispersion is studied. The column efficiency in systems with significant pressure drops is affected by changes in: the linear velocity of the mobile phase; the diffusion coefficients; and the capacity factors of the solutes along the column. The overall efficiency of the chromatographic system can be calculated if, as is the case for open tubular columns, adequate plate height equations are available.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 491-497 
    ISSN: 0935-6304
    Keywords: Fast GC ; narrow-bore columns ; trace analysis ; splitless injection ; on-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The use of hot splitless, cold splitless, and on-column injections for trace analysis in narrow-bore capillary GC is evaluated. Despite the low flow rates for the columns used, the required splitless times for splitless injections can be surprisingly short if liners with a small inside diameter are used. On-column injection can be applied by using an appropriate normal-bore precolumn coupled to the narrow-bore analytical column using a specially designed low dead volume column connector. The effects of the experimental conditions such as sample volume, injection temperature, and initial oven temperature on peak focusing and the discrimination and degradation behavior of the analytes are discussed. The possibilities to obtain sensitive and fast separations are illustrated by various applications.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 5 (1993), S. 413-419 
    ISSN: 1040-7685
    Keywords: capillary GC ; narrow-bore columns ; GC/MS ; ion trap mass spectrometry ; detection limits ; working range ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fast gas chromatographic separations can be achieved by vacuum-outlet operation and by applying narrow-bore columns. In this work, the combination of 50 μm i.d. columns with ion trap mass spectrometric detection is evaluated. Detection limits in the electron ionization mode, and in the chemical ionization mode using CH4 as the reaction gas, are 1 pg and 5 pg, respectively. Owing to the high sensitivity of the ion trap mass spectrometer, a significant improvement in the working range in comparison with other detection systems is obtained. The small column flows cause no loss of mass spectral resolution and sensitivity. The performance of the system is demonstrated by the analysis of some real-world samples.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 449-456 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography (SFC) ; Packed columns ; Pressure drop ; Selectivity ; Resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The influence of pressure drop on retention, selectivity, plate height and resolution was investigated systematically in packed supercritical fluid chromatography (SFC) using pure carbon dioxide as the mobile phase. Numerical methods developed previously which enabled the prediction of pressure gradients, diffusivities, capacity factors, plate heights and resolutions along the length of the column were used for the model calculations. The effects of inlet pressure and supercritical fluid flow rate on selectivity and resolution are studied. In packed column SFC with pure carbon dioxide as the mobile phase, the pressure drop can have a significant effect on resolution. The flow rate is shown to have a larger effect than generally realized. The calculated data are shown to be in good agreement with the experimental results. Finally, the variation of the chromatographic parameters along a 5.5 meter long model SFC column is illustrated. The possibilities and limitations of using long packed columns in SFC are discussed. It is demonstrated that long columns with large plate numbers do not necessarily yield better separations.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0935-6304
    Keywords: High-speed GC ; Electron capture detector (ECD) ; Detection limits ; PCBs ; Pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In this work the combination of high-speed narrow-bore capillary GC with electron capture detection is evaluated. The make-up gas flow rate is a key parameter in the successful coupling of narrowbore columns and ECD detection. The make-up flow has to be as high as possible to eliminate peak tailing caused by the large detection cell volume. The sensitivities at these elevated make-up flow rates (400 to 1000 ml/min), measured for some pesticides like HCB and dieldrin, were very good. Detection limits for these compounds of 0.1 pg were obtained, resulting in minimum detectable concentrations of approximately 0.2 ppb. The performance of the system is illustrated by several high-speed analyses of environmentally relevant samples of PCBs and pesticides.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 458-466 
    ISSN: 0935-6304
    Keywords: SFC Pressure drop ; Efficiency ; Compressibility effects ; Analysis time ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The influence of the pressure drop on the efficiency and speed of analysis in packed and open tubular supercritical fluid chromatography (SFC) is described: methods previously developed to describe the effects of mobile phase compressibility on the performance of open tubular columns in SFC have been extended to packed columns.The Horvath and Lin equation has been used to elucidate the influence of variations in velocity, diffusivity, and capacity factor along the column on the overall efficiency of packed column SFC. In packed columns, in contrast with the situation in open tubular columns, because the increase in velocity is no longer compensated by an increase in diffusion coefficients, the increase in both linear velocity and capacity factor which result from a significant pressure drop cause the plate height to increase along the column.The effect of fluid decompression along the length of the column on the speed of analysis in SFC has been studied and numerical expressions derived which enable calculation of compressibility correction factors for the plate height. Both the f1 and f2 correction factors remain very close to unity for acceptable pressure drops, which means that the pressure drop has virtually no effect on the number of plates generated per unit time for an unretained component. For retained species, the decompression of the mobile phase across the column causes the capacity factor to increase and hence leads to increased analysis times.